100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

IEC Year 3 Exam Study & Practice Questions With Verified Correct Answers | Updated

Rating
-
Sold
-
Pages
215
Grade
A+
Uploaded on
19-03-2024
Written in
2023/2024

IEC Year 3 Exam Study & Practice Questions With Verified Correct Answers | Updated A 120/240-volt, 1Ø, 3-wire branch circuit is installed underground (in PVC with an EGC) to serve receptacles and lighting in a separate building. Is a ground rod or similar grounding electrode required at the separate building? Select one: a.Yes b.No - ANSWER : b. no A service is installed in building A. Building B contains a 3Ø motor as well as lights and a receptacle. From building A, a 4-wire feeder is pulled to a sub-panel in building B. This feeder is installed underground in one PVC conduit. You must install ___.I. an EGC with the circuitII. a grounding electrode at the 2nd building Select one: a.I only b.II only I & II er I nor II - ANSWER : c. both I & II An acceptable method for grounding a 120/208-V, 3Ø, 4-wire electrical system at a separate building or structure is to connect ___ conductor to the grounding electrode. I. the grounded II. the grounding III. an ungrounded Select one: a.II only b.I only c.I or II only d.III only e.II & III only - ANSWER : a. II only A 120/208-volt, 4-wire, three-phase feeder supplies power from one building to a second building. At the second building, the neutral and equipment grounding conductors are required to be ___. Select one: separated, and the equipment grounding conductor is required to be connected to a grounding electrode d together, and not required to be connected to a grounding electrode separated, and grounding either conductor is optional separated, and the neutral is required to be connected to a grounding electrode cted to a grounding electrode - ANSWER : a. kept separated, and the equipment grounding conductor is required to be connected to a grounding electrode A 120/240-volt, 1-ph, 3-wire feeder is to be installed underground in Schedule 40 PVC to feed a main breaker panelboard that is located in another building. How should the neutral and EGC be connected in the panel at second building? The panel at the second building has an insulated neutral bar and a ground bar that is bonded to the metal panel can (enclosure). A GEC has also been installed from the ground bar to the grounding electrode.I. Connect the neutral to the neutral bar and the EGC to the ground bar.II. Use a main bonding jumper to connect the neutral bar to the ground bar. Select one: a.I only b.II only I & II er I nor II - ANSWER : a. I only

Show more Read less
Institution
IEC
Course
IEC











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IEC
Course
IEC

Document information

Uploaded on
March 19, 2024
Number of pages
215
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • iec

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
694
Member since
3 year
Number of followers
431
Documents
7259
Last sold
6 days ago
EN.CY.CLO.PE.DI.A

Hello, I am Passionate about education with over 7yrs teaching.. Welcome to my page...my documents are 100% guaranteed to help you Ace in your career path, Combining a wide view of career courses education Journey Proffesionaly. Will be very helpful for those students who want to make a change in nursing field and other close courses . Please go through the sets description appropriately before any purchase. The *Sets have been used years in years out by serious students to exercise, revise and even pass through their examinations. All revisions done by Expert Minds. This Gives You No Excuse To Leave A Bad Review. Thankyou . SUCCESS IN YOUR EDUCATION JOURNEY !! GOODLUCK IN YOUR STUDIES.

Read more Read less
3.8

102 reviews

5
53
4
12
3
14
2
6
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions