Oil Burners State Test Verified 100% Correct!! how should an oil tank be supported Ridgid non-combustible supports to prevent settling, sliding, or lifting what is the wire gauge used on oil burner circuits 14 gauge minimum how is an oil burner wired oil burners are wired intermittent or interrupted what does intermittent or interrupted mean intermittent - Transformer stays on throughout the burner firing cycle interrupted - Transformer drops out after flame established who approves oil burners in Mass the fire marshal what does the term Marshall mean State Fire Marshal what size vent pipe is required with a 2-inch fill pipe 2 inch minimum what are the elements found in fuel oil 85% carbon 15% hydrogen what is fuel oil a hydrocarbon how must fuel oil be prepared for combustion it must be atomized or vaporized, and mixed with air What is a BTU (British Thermal Unit)? the amount of heat necessary to raise 1 lb of water, 1° Fahrenheit how many BTUs are there in a gallon of number 2 fuel 140000 what determines the GPH of a nozzle the orifice what is a degree day 65 degrees Fahrenheit minus the daily average temperature can materials other than steel be used in fuel oil tanks yes, is approved what does the word approved mean accepted by the Marshall, or by a laboratory, which is by the Marshall when is a combustion efficiency test required by law after installations and alterations what control shuts off the oil burner in the event of excessive heat temperature in the appliance the high limit name three functions of an oil pump pick up, pressurize, and strain oil how is oil flow adjusted in a rotary burner by the constant level valve how is safety timing checked on a stack switch remove the stack switch from its holder or disconnect Terminal 3, fire the control and time it's lockout what is safety lockout timing firing under 3 GPH 45 seconds how should a stack control be mounted according to code not rigidly mounted why should stack switch not be rigidly mounted so it can be easily removed for cleaning and inspection, without disturbing any wiring what safety devices are found on a gravity burner a constant level valve, and a solenoid valve when is a tank vent pipe required on all tanks what must be done after an installation has been completed a certificate of completion must be submitted where are certificates of completion submitted local fire department what is the time limit for submitting a certificate of completion 72 hours, excluding weekends and holidays what is on a certificate of completion Name of burner Approval number issued by Marshall Grade of fuel oil used Size of tank in gallons Any special requirements that pertain to the installation Assurance of compliance with regulations Assurance that proper maintenance instructions have been left with the owner or occupant Name and address of the owner or occupant of the premises where the installation or alteration was made Results of combustion efficiency test and nozzle size what kind of joints are used on tank installations swing joints why are swing joints used to allow for movement or settling without pipe and tank damage, and to enable the pipe to pitch back towards tank what is the minimum distance that a burner must be from a tank 5 ft how many gallons of oil may be stored without a permit 10 gallons how much outside or replacement air is needed in a confined space 140 square inch top and bottom per gallon per hour how much outside of replacement air is needed in a boiler room of tight Construction 28 square inches per gallon per hour what is a flame detector

Show more Read less
Institution
Course

Content preview

Oil Burners State Test Verified 100% Correct!!
how should an oil tank be supported
Ridgid non-combustible supports to prevent settling, sliding, or lifting
what is the wire gauge used on oil burner circuits
14 gauge minimum
how is an oil burner wired
oil burners are wired intermittent or interrupted
what does intermittent or interrupted mean
intermittent - Transformer stays on throughout the burner firing cycle

interrupted - Transformer drops out after flame established
who approves oil burners in Mass
the fire marshal
what does the term Marshall mean
State Fire Marshal
what size vent pipe is required with a 2-inch fill pipe
2 inch minimum
what are the elements found in fuel oil
85% carbon
15% hydrogen
what is fuel oil
a hydrocarbon
how must fuel oil be prepared for combustion
it must be atomized or vaporized, and mixed with air
What is a BTU (British Thermal Unit)?
the amount of heat necessary to raise 1 lb of water, 1° Fahrenheit
how many BTUs are there in a gallon of number 2 fuel
140000
what determines the GPH of a nozzle
the orifice
what is a degree day
65 degrees Fahrenheit minus the daily average temperature
can materials other than steel be used in fuel oil tanks
yes, is approved
what does the word approved mean
accepted by the Marshall, or by a laboratory, which is by the Marshall
when is a combustion efficiency test required by law
after installations and alterations
what control shuts off the oil burner in the event of excessive heat temperature in
the appliance
the high limit
name three functions of an oil pump
pick up, pressurize, and strain oil
how is oil flow adjusted in a rotary burner
by the constant level valve

, how is safety timing checked on a stack switch
remove the stack switch from its holder or disconnect Terminal 3, fire the control and
time it's lockout
what is safety lockout timing firing under 3 GPH
45 seconds
how should a stack control be mounted according to code
not rigidly mounted
why should stack switch not be rigidly mounted
so it can be easily removed for cleaning and inspection, without disturbing any wiring
what safety devices are found on a gravity burner
a constant level valve, and a solenoid valve
when is a tank vent pipe required
on all tanks
what must be done after an installation has been completed
a certificate of completion must be submitted
where are certificates of completion submitted
local fire department
what is the time limit for submitting a certificate of completion
72 hours, excluding weekends and holidays
what is on a certificate of completion
Name of burner
Approval number issued by Marshall
Grade of fuel oil used
Size of tank in gallons
Any special requirements that pertain to the installation
Assurance of compliance with regulations
Assurance that proper maintenance instructions have been left with the owner or
occupant
Name and address of the owner or occupant of the premises where the installation or
alteration was made
Results of combustion efficiency test and nozzle size
what kind of joints are used on tank installations
swing joints
why are swing joints used
to allow for movement or settling without pipe and tank damage, and to enable the pipe
to pitch back towards tank
what is the minimum distance that a burner must be from a tank
5 ft
how many gallons of oil may be stored without a permit
10 gallons
how much outside or replacement air is needed in a confined space
140 square inch top and bottom per gallon per hour
how much outside of replacement air is needed in a boiler room of tight
Construction
28 square inches per gallon per hour
what is a flame detector

Written for

Course

Document information

Uploaded on
March 7, 2024
Number of pages
6
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QUICKEXAMINER Walden University
Follow You need to be logged in order to follow users or courses
Sold
92
Member since
2 year
Number of followers
44
Documents
5418
Last sold
1 week ago
QUICK EXAMINER

Looking for high-quality study materials to help you excel? You’re in the right place! I provide well-structured notes, summaries, essays, and research papers across various subjects, all designed to make studying easier and more efficient. Why Choose My Materials? ✔ Comprehensive and well-organized content ✔ Easy-to-understand explanations ✔ Time-saving summaries for exams and research ✔ Carefully curated to ensure accuracy and clarity Each document is crafted to provide valuable insights, helping you grasp concepts quickly and effectively. Whether you're preparing for exams, writing an assignment, or just need clear and concise notes, my resources will support your academic journey. Browse my collection and take your studies to the next level

Read more Read less
3.6

15 reviews

5
5
4
5
3
2
2
0
1
3

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions