Electrical journeyman Exam Questions And Answers 100% Verified
Electrical journeyman Exam Questions And Answers 100% Verified What does FLC stand for - answerFull load current An electrical device that consists of a frame a plunger and uses an up and down motion to operate - answerSolenoid 240 volt to ground, 200 amp panel in condition 3 needs a minimum front clearance of how many feet - answer4 What is the minimum clearance in front of a service panel - answer3 feet The width of a 120/240 volt panel working area shall be a minimum of how many feet and the door shall be openable to at least 90° - answer2 1/2 Manhole cover shall weigh more than how many pounds - answer100 A 240 volt boat hoist receptacle has to be? - answerGFCI protected Non-dwelling unit receptacles installed in or on the ___ shall be GFCi protected - answerRooftops outdoors sinks What is the minimum rating for a laundry circuit and a single-family dwelling - answer20 amps 1500 w Branch circuits _______ or larger shall supply only non lighting loads - answer50 amps What type of lamp holder shall be connected to a load in excess of 20 amps - answerHeavy duty The laundry outlet shall be installed within how many feet of the designated appliance location - answer6 Receptacle outlet in the floor shall not be counted as part of the required number of wall receptacle outlets unless located within how many inches of the wall - answer18 What is the minimum number of small appliance circuits for a single-family dwelling - answer2 Other than countertop appliances what type of device is allowed to utilize the small appliance circuits in a single family dwelling - answerRefrigerator clocks cooking equipment Receptacle outlets shall be installed so that no point along the wall line of a kitchen countertop is more than how many inches measured horizontally from a receptacle outlet in that space - answer24 What is the minimum length of a countertop in a kitchen that requires the installation of a receptacle - answer12 inches Island countertops, with a minimum of dimension of 12" w x 24" D must have at least how many receptacle outlets - answer1 18 ft of show window requires how many receptacles above window - answer2 one every 12' What is the maximum distance from a rooftop unit that the rooftop GFCI service receptacle shall be located - answer25' A conference room is 250 ft and has a 12.5 ft wall how many floor receptacles are needed - answer1 Does a vehicle garage door require illumination under the illuminated entryway rule - answerNo it needs a hinge General branch circuit lighting load for a hospital Shelby calculated at ______ watts per square foot - answer2 Indwelling units new additions to the lighting branch circuit Shelby calculated in accordance with 220.12 when over ______ square feet - answer500 Where SE cable enters the building the conduit has to be - answerSealed The conductors for festoon lighting shall be supported by messenger wire and all spans exceeding - answer40 ' What is the minimum service rating for a single-family dwelling with six or more two wire Branch circuits - answer100
Written for
- Institution
- Journeyman Electrician
- Course
- Journeyman Electrician
Document information
- Uploaded on
- March 5, 2024
- Number of pages
- 7
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
electrical journeyman exam questions and answers 1
Also available in package deal