Journeyman Final Exam Questions And Answers 100% Verified
Journeyman Final Exam Questions And Answers 100% Verified Which of the following conductor insulation types, if any, is/are acceptable for wiring in a fluorescent luminaire when the branch-circuit conductor passes within three (3) inches of the ballast? I. THW II. THWN 1.) neither I nor II 2.) both I and II 3.) I only 4.) II only - answerAnswer: both I and II Table 310.4(A) on page 70-153 of the NEC® 2020 Fire pump supply conductors on the load side of the final disconnecting means and overcurrent device(s) are permitted to be routed through the inside of a building if _____. 1.) concealed within walls, floors, or ceilings that provide a thermal barrier of material that has at least a 15-minute fire rating 2.) encased in at least two (2) inches of brick or concrete 3.) installed in raceways with power conductors 4.) installed in a listed electrical circuit protective system with a 1-hour fire rating - answerAnswer: encased in at least two (2) inches of brick or concrete 695.6(A)(2)(4) on page 70-602 of the NEC® 2020 In general, with respect to the service disconnecting means, the grounding electrode conductor shall be connected to the grounded service conductor on _____. I. the supply side II. the load side 1.) both I and II 2.) I only 3.) II only 4.) either I or II - answerI only 250.24(A)(5) on page 70-114 of the NEC® 2020 When made up with threaded couplings, straight runs of trade size 2-inch rigid metal conduit (RMC) shall be supported at intervals of at LEAST every _____. 1.) 20 feet 2.) 14 feet 3.) 16 feet 4.) 10 feet - answeranswer: 16 ft 344.30(B)(2) on page 70-207 of the NEC® 2020,Table 344.30(B)(2) on page 70-207 of the NEC® 2020 Where a 36 in. long conduit contains one (1) ungrounded conductor, one (1) grounded conductor, and one (1) equipment grounding conductor, the conduit may be filled to a MAXIMUM of _____ of its cross-sectional area. 1.) 53 percent 2.) 31 percent 3.) 60 percent 4.) 40 percent - answer40 percent Chapter 9, Table 1 on page 70-695 of the NEC® 2020 Where a fuse or inverse time circuit breaker is used for overload protection for a hermetic motor-compressor, this device shall be rated at NOT more than _____ of the motor-compressor rated load-current. 1.) 115 percent 2.) 175 percent 3.) 150 percent 4.) 125 percent - answer125 percent 440.52(A)(3) on page 70-339 of the NEC® 2020 Nonconductive optical fiber cable may occupy the same raceway with conductors supplying lights and power, provided the operating voltage does NOT exceed _____. 120 volts 250 volts 600 volts 1000 volts - answer1000 Volts 770.133 on page 70-660 of the NEC® 2020 A metal electrical junction box
Written for
- Institution
- Journeyman Electrician
- Course
- Journeyman Electrician
Document information
- Uploaded on
- March 5, 2024
- Number of pages
- 11
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
journeyman final exam questions and answers 100 v
Also available in package deal