NICET Level 2 ITM of Water Based Systems Already Graded A+
NICET Level 2 ITM of Water Based Systems Already Graded A+ When placing a LOTO on a system, how many locks should be applied? personnel working on the system. As many locks as their are A ladder must be able to support ____ times the weight of the expected load 3.3 It is acceptable to enter into a confined space without an attendant, but only if all other precautions and PPE are taken. False A defective air pressure gauge on the supply air of a dry pipe system is considered a _____ deficiency Critical When taking a sprinkler system out of service, the following are approved sources of a temporary water supply -A hose from a fire hydrant to the FDC -A portable tank and pump -A standby fire department pumper True When using a ladder for electrical work, _______ When using an aerial lift, you must -Tie off with a lanyard -Wear a hard hat -Have received appropriate training True The rails must be non-conductive. When an employee may be exposed to hazardous chemicals, when must training be given? -When they might be exposed to said chemical -When new chemicals have been added to the work place True Toxic chemicals will be hazardous in a confined space when the ______ is exceeded A hydropnuematic pump is used to check for air leaks on a dry pipe system False When shutting down a system for impairment you must hang a tag at _______ PEL System control valve and the FDC Prior to entering a confined space, oxygen must be tested to be between ______ and maximum levels the minimum Before opening a fire pump controller and measuring voltage and amps you must be trained in _____ NFPA 70E, arc flash, and the proper PPE When testing a antifreeze solutions, what tools are recommended? Refractometer, or hyrdometer The person who performs the LOTO on a piece of equipment to perform repairs or maintenance is the _______ authorized person The minimum size of an impairment tag is _____ in. 4x6 Safe oxygen levels in a confined space is between _____ and _____ % The correct angle of a ladder from the base to the wall is ____ degrees Each employee exposed to fall hazards must be trained -When the employee is assigned to a work area where fall hazards exist -When there is a new fall hazard -When the fall protection program is inadequate True 19.5 and 23.5 75 1/2 When a fire protection system is out of service for more than ____ hrs at least one of the following shall be provided -Evacuation of the building of section affected by the OOS system -An approved fire watch -Temporary water supply -a program to eliminate ignition sources and limit the amount of fuel available to the fire An obstructed sprinkler is not an example of a critical deficiency Your safety LOTO lock can be used for other purposes False Closed valves are the primary cause of failure for water based fire protection systems 10 False True _____ is the responsible party for ensuring sprinkler systems are maintained and operational owner Inspection and test records are kept for ____ yrs after the next test. All inspection and testing records shall be given to _____ upon request Inspection and testing records are kept by _____ as per NFPA 25 1 the AHJ the owner During an inspection, a concern with the layout of the system, and or storage of hazardous/flammable chemicals, is noted by the inspector. They should the Provide the owner with a separate document of the concern Acceptance records are kept _____ for the life of the system
Written for
- Institution
- NICET
- Course
- NICET
Document information
- Uploaded on
- February 26, 2024
- Number of pages
- 13
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nicet level 2 itm of water based systems already g
Also available in package deal