Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ACI GRADE 1 FIELD TESTING CERTIFICATION PRACTICE TEST – IRVING GRADED A+

Beoordeling
-
Verkocht
-
Pagina's
9
Cijfer
A+
Geüpload op
15-02-2024
Geschreven in
2023/2024

ACI GRADE 1 FIELD TESTING CERTIFICATION PRACTICE TEST – IRVING GRADED A+ For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - -False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - - The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - -30 to 120 degree F ( 0 to 50 degree C) A composite sample is not needed if only the temperature test is being run. (T or F) - -True The temperature of fresh concrete in a placement must be measured by inserting a thermometer into the top six inches of concrete. (T or F) - -False (3 in.) The temperature of the concrete is recorded to the nearest ______ degree F (______ degree C) - - 1 degree F (0.5 degree C) ASTM C1064 states the container used to measure temperature of concrete must be large enough to provide at least 5 inches of concrete around the sensor. (T or F) - - Calibrate the temperature measuring device at least __________, or whenever there is a question of accuracy. - -Annually After the thermometer is placed in the concrete: - -Gently press concrete around the thermometer According to ASTM C1064, what is one reason to take the temperature of concrete? - -Verify conformance It is allowable to remove the temperature measuring devices from the freshly mixed concrete to read the temperature if you cannot see the reading. (T or F) - -False The maximum allowable time between obtaining the first and last portions of the composite sample may not exceed 5 minutes. (T or F) - -False Start molding specimens for strength tests within 30 minutes after fabricating the composite sample. (T or F) - -False (15 mins) The composite concrete sample must be protected from sun, wind, contamination and rapid evaporation. (T or F) - -False (Contamination and rapid evaporation)

Meer zien Lees minder
Instelling
ACI GRADE 1 FIELD TESTING CERTIFICATION
Vak
ACI GRADE 1 FIELD TESTING CERTIFICATION

Voorbeeld van de inhoud

ACI GRADE 1 FIELD TESTING CERTIFICATION PRACTICE TEST – IRVING
GRADED A+


For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete
sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - ➡-False (2-5
minutes)



The temperature measuring device must be accurate to within 0.1 degree. (T or F) - ➡-



The temperature measuring device shall have a capacity of measuring temperature of freshly mixed
concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - ➡-30 to 120
degree F ( 0 to 50 degree C)



A composite sample is not needed if only the temperature test is being run. (T or F) - ➡-True



The temperature of fresh concrete in a placement must be measured by inserting a thermometer
into the top six inches of concrete. (T or F) - ➡-False (3 in.)



The temperature of the concrete is recorded to the nearest ______ degree F (______ degree C) - ➡-
1 degree F (0.5 degree C)



ASTM C1064 states the container used to measure temperature of concrete must be large enough to
provide at least 5 inches of concrete around the sensor. (T or F) - ➡-



Calibrate the temperature measuring device at least __________, or whenever there is a question of
accuracy. - ➡-Annually



After the thermometer is placed in the concrete: - ➡-Gently press concrete around the thermometer



According to ASTM C1064, what is one reason to take the temperature of concrete? - ➡-Verify
conformance

, It is allowable to remove the temperature measuring devices from the freshly mixed concrete to read
the temperature if you cannot see the reading. (T or F) - ➡-False



The maximum allowable time between obtaining the first and last portions of the composite sample
may not exceed 5 minutes. (T or F) - ➡-False



Start molding specimens for strength tests within 30 minutes after fabricating the composite sample.
(T or F) - ➡-False (15 mins)



The composite concrete sample must be protected from sun, wind, contamination and rapid
evaporation. (T or F) - ➡-False (Contamination and rapid evaporation)



If the concrete contains aggregates larger than those that are appropriate for a size of mold or
equipment used, the sample should be wet-sieved before making the test. (T or F) - ➡-False (wet
screened)



The composite sample not be remixed before beginning any tests. (T or F) - ➡-False



Sampling should normally be performed, as the concrete is discharged from the mixer. (T or F) - ➡-
True



ASTM Method C172 includes the sampling from stationary mixers, paving mixers, truck mixers,
agitators, and non-agitating equipment. (T or F) - ➡-True



After sampling is completed, start the tests for slump and air content within: - ➡-None of the above
(5 mins)



In any case, do not obtain samples until: - ➡-All the water and admixtures have been added to the
concrete



No samples shall be taken before ______ or after ______ of the batch has been discharged. - ➡-



When strength tests are to be made, the minimum size of the composite sample shall be: - ➡-1
cubic foot

Geschreven voor

Instelling
ACI GRADE 1 FIELD TESTING CERTIFICATION
Vak
ACI GRADE 1 FIELD TESTING CERTIFICATION

Documentinformatie

Geüpload op
15 februari 2024
Aantal pagina's
9
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$5.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
AcademiaGiant

Maak kennis met de verkoper

Seller avatar
AcademiaGiant NCSU
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
3
Lid sinds
2 jaar
Aantal volgers
2
Documenten
294
Laatst verkocht
1 jaar geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen