Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.

Vendu
1
Pages
15
Grade
A+
Publié le
16-01-2024
Écrit en
2023/2024

NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS. Type ____ is multiconductor cable identified for use as underground service entrance cable. Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system 6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. 30 Amps Where skin effect exist the ferromagnetic envelope shall be bonded at ____. Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. Locking The maximum voltage drop from service point to the last over-current device in a dwelling unit? 4% Which of the following statements best describe the grounding requirement for central vacuum outlet Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas Do not include The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature 3 inches Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. 6 ft Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed Green finish Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating Hexagon The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? 5000 watts Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. 3 ft (36 inches) —— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing installation is where there is no evidence of over-fusing or tampering. Class H Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F 3" inches The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. 8 In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? Combination range hood/microwave oven Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the service or separately derived system disconnect Included in the manufactures instructions Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? EVJ Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed Type S fuse Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a lesser distance is permitted by and exceptions 8'ft Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings with conductors of Class 1 or electric light or power conductors, unless ____. Separated by barrier In the critical care areas of health care centers, each patient bed shall be provided with a minimum of ____ duplex receptacles 3 duplex (6 single) The equipment system shall supply major electric ____ necessary for patient care and basic hospital operation Equipment The essential electrical system in a healthcare facility shall be compromised of the emergency system and the: equipment system Locations were flammable anesthetics are employed are class I,Division I locations that shall extend upwards to a level 5'ft above the floor In a healthcare facility receptacles and attachment plugs in a hazardous (classified) location with an anesthizing area shall be listed for use in class I group ____ locations Group C In anesthetic,areas health care equipment frequently in contact with bodies of persons shall not exceed ____ volts. 10 Volts In anesthetic areas, low-voltage equipment that is frequently in contact with the bodies of persons or has exposed current-carrying elements shall operate on an electrical potential of 10 volts or less,be moistur- resistant, be approved as intrinsically safe or double-insulated equipment. In a healthcare facility, the maximum internal current permitted to flow through a line isolated monitor,when any point of the isolated system is grounded, shall be ____ . 1 milliamperes Transfer eguipment, including automatic transfer switches,shall be automatic, identified for emergency use , approved by the authority having jurisdiction Automatic transfer switches shall be ____ operated and ____ held Electrically operated and mechanically Audible and visual signal devices for an emergency system shall be provided,where practicable, for the purpose(s) of indicating that the battery is carrying load, derangement of emergency source, that the battery charger is not functioning Wiring from an emergency source to emergency loads shall ____ ____ ____ ____ of all other wiring Be kept entirely independent of all other wiring Emergency circuit wiring shall be permitted to enter which of the following types of equipment with normal circuit wiring? Transfer switches, exit or emergency luminaries supplied from two sources Emergency circuit wiring must be designed and located in such a manner so as to minimize the possibility of failure because of ____, ____, ____. Vandalism,flood,fire. Emergency lighting emergency power or both must be available in the building within a time not exceeding ____seconds 10 seconds A storage battery supplying emergency lighting and power shall maintain not less than 87.5% of full fault is that total low for a period of at least 1.5 hours Where an internal combustion engine is used as the prime mover for the emergency system and on-site fuel supply shall be provided for not less than 6 hours of full-demand operation of the system Unit equipment (battery packs) shall be on the same branch circuit as that serving the normal lighting in the area and connected ahead of any local switches The alternate source for emergency systems shall not be required to have ground-fault protection of equipment with automatic disconnecting means They equipment grounding terminal buses of the normal and essential branch-circuit panelboards serving the same individual patient care vicinity shall be connected together with an insulated continuous copper conductor not smaller than 10 AWG Each patient bed location in critical care areas shall be supplied by at least 2 branch circuits. Individual branch circuit shall not be required for portable mobile and transportable medical x-ray equipment requiring a capacity of not over 60 amperes The ampacity of supply branch circuit conductors and the current rating of all the current protective devices for x-ray equipment shall not be less than 50 of the momentary rating or 100 percent of the longtime rating, whichever is greater There shall be a minimum of one 20A branch circuit for laundry outlets required by 210.52(f) Indoor electrical vehicle charging sites, unless specifically listed for the purpose and location,the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than 18"Inches and not more than 4'FT Type 3 surge protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment served. If included in the manufacture's instructions, the type 3 SPD connection must be a minimum 30ft. Of conductor distance from the service or separately derived system disconnect Access opening in a manhole shall be not less than 26" In a dwelling unit which appliance is allowed to have a 24" cord with attachment ground plug? Combination range hood/Microwave Knife switches rated for more than 1200 amps at 250v or less, can be used only as isolating switch, shall not be opened under load. Two or more 20A small appliance branch circuits shall be provided to supply power for receptacles outlets in the dwelling unit kitchen,dining room,breakfast room, pantry, or similar dining areas At least one 125v, single phase, 15A or 20A, duplex receptacle shall be provided in the elevator hoistway pit. The feeder and branch circuit overcurrent devices shall be accessible by ? Authorized persons only Receptacle outlet in floor shall not be counted as part of the required number of receptacle outlets unless located within 18" of the wall A door used by personnel to exit the work space that is less than 25' feet from the working space shall, swing outward with simple pressure. Cables with entirely nonmetallic sheath (ROMEX) shall be permitted to enter the top of a surface mounted enclosure through one or more non flexible raceways not less than 18" In straight pull, the length of the box shall not be less than 8 times the trade size of the largest raceway. A separate branch circuit shall supply the elevator hoistway pit lighting and receptacle. The required lighting shall not be connected to the load side of a ground-fault circuit interrupter. What is true about installation of a Type 1 TVSS Can be connected to line side of service disconnect. A load demand factor of 75% is permitted for four or more appliances fastened in place such as waste disposal, dishwashers, trash compactors, water heater, etc, Which of the following statements best describes the grounding requirements for central vacuum outlet assemblies? Accessible non-current-carrying metal parts are required to be connected to an equipment grounding conductor. Service drops installed over roofs shall have a vertical clearance of 8ft above the roof surface,unless a lesser distance is permitted by an exception The maximum total voltage drop on branch-circuit conductors is 3% percent. Which of the following shall not be connected to the life safety branch in a hospital? General illumination How many receptacles are required within the perimeter of a balcony, deck or porch with a useable area of less than 20 square FT. 1 Branch circuit conductors within 3in. Of a ballast shall have an insulation temperature rating not lower than 90 degrees celsius (194 degrees Fahrenheit) A multi family building has 12 units. The system voltage is 120/240V, single-phase. Each 1,500 sq ft unit contains the following: Dishwasher 1.50 kva Water Heater 4kw Dryer 4.50 kW

Montrer plus Lire moins
Établissement
NYC MASTER ELECTRICIAN
Cours
NYC MASTER ELECTRICIAN









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NYC MASTER ELECTRICIAN
Cours
NYC MASTER ELECTRICIAN

Infos sur le Document

Publié le
16 janvier 2024
Nombre de pages
15
Écrit en
2023/2024
Type
Examen
Contient
Questions et réponses

Sujets

$14.49
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Reviews from verified buyers

Affichage de tous les avis
6 mois de cela

Review is extremely straightforward

6 mois de cela

Thank you Richiew, for the kind 5-star review on my study material. I truly appreciate your feedback and support. Wishing you the very best in your upcoming exams!

5.0

1 revues

5
1
4
0
3
0
2
0
1
0
Avis fiables sur Stuvia

Tous les avis sont réalisés par de vrais utilisateurs de Stuvia après des achats vérifiés.

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Topscorer1 South University
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
247
Membre depuis
4 année
Nombre de followers
207
Documents
7292
Dernière vente
2 semaines de cela
TOPSCORER1

Expert Study Solutions | Nursing, Business, Accounting & More! Looking for top-quality study materials to excel in college or university? You're in the right place! I provide highly graded, almost A+ solutions across various subjects, including Nursing (my main expertise), Business, Accounting, Statistics, Chemistry, Biology, and many more. ✅ Accurate & Well-Researched Guides ✅ Comprehensive Solutions for Better Grades ✅ Student-Friendly Approach & Full Support ✅ Satisfaction Guaranteed – Refund Available if Not Satisfied I’m committed to helping students succeed by providing reliable, high-quality academic resources. Let’s boost your grades together!

Lire la suite Lire moins
3.8

40 revues

5
22
4
5
3
4
2
0
1
9

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions