100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

NMTCB BOARD EXAM GUIDE 2024

Rating
-
Sold
-
Pages
14
Grade
A
Uploaded on
05-01-2024
Written in
2023/2024

SPECT QC Energy Peak rmity Resolution Linearity Center of Rotation COR high - count extrinsic flood field uniformity correction Jaszczak Center of Rotation COR - NTRADY12 COR reduces spatial resolution & blurring Image contrast a measure Performed to ensure center field of view of camera detect or matches computer software High count extrensic flood - field uniformity correction Performed directly by manufacturer used to ensure efficiency photon decfection is constant across an surface of collimated detector . -30-100 mil . counts defeciency causes ring artifact in SPECT Imaging Jaszczak SPECT Phantom test - Jaszczak determines 3D contrast , resolut von , & uniformity of SPECT camera . - s Combined SPECT CT QC Includes all QC + Registration attenuation correction accuracy or mis registration consequences SPECT QC NMTCB SPECT / CT QC 1. Peak 2. uniformity 3. Resolution 4. Untarity 5. High Count extrinsic floodfield uniformity Correction B 6 COR Dopamos 7. Jaszczak 8.Source strength 9.Transmission source mechanics Energy Peak confirm the camera is counting Photon in the Proper energy Windows . -Transmission source mechanics confirm operation of the source Shutter & translating mechanics , & reference blank transmission Scan should be acquired . Weekly ( preferably daily) SPECT / CT X - ray based NMTCB QC - all spect / CT QC including CT QC 1.Calibration uniformity Calibration CT number inserted Phantom L considerd not calibrated if error is greater than 5 Hounsfield units Field uniformity ensures uniform response throughout FOV - Brain Perfusion raphas Rapha Team Exametazine ECD , Dicisate , Cretec HMPAO Brain perfusion dose 10-20mCi Brain perfusion Indications 1. cerebrovascular disease - acute stroke transient ische- mic attacks 2. Dementia - Alzheimer's disease , multi - infarct dementia 3. Psychiatric disorder - affective disorder ( depre && Von Schizophrenia 4. Seizure disorder - idenification & location of focal epilepsy sites 5. Head Trauma ( cerebral brain death ) Brain perfusion imaging time 15-20min post injection (preferably @ 45min) Brain cross sections Mans axial Coronal sagital PET Oncology rapha F18- FDG FDG-F18 dose 5-20mCi intravenously FDG-F18 pt questions Pt History , surgenes , chemo radiation therapy , previous Imaging results , Pt . cooperation lying still for hrs & arms up . Laxative may given night before to prevent bowel inter ferring Blood Glucose Less than 200mcg Bone pain associated w / metastatic bone disease raphas Sr 89 Sm 153 P32 ST89 Chloride half life 50.5day ST89 Chloride analog -calcium analog cleared from blood stream & localizes in bont SR89 Chloride localization -localizes in areas of active osteogenesis in metastatic Sites longer than in normal bone -Sr 89 dose 40-60uCi & repeat dose @ 12 weeks Moving a pt from wheelchair to bed; wheelchair is in what degree 45° Filters that get rid of star artifact Ramp filter, high pass filter

Show more Read less
Institution
NMTCB BOARD
Module
NMTCB BOARD









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NMTCB BOARD
Module
NMTCB BOARD

Document information

Uploaded on
January 5, 2024
Number of pages
14
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NMTCB BOARD EXAM GUIDE 2024 SPECT QC Energy Peak 2.uniformity Resolution Linearity Center of Rotation COR high - count extrinsic flood field uniformity correction Jaszczak Center of Rotation COR - NTRADY12 COR reduces spatial resolution & blurring Image contrast a measure Performed to ensure center field of view of camera detect or matches computer software High count extrensic flood - field uniformity correction Performed directly by manufacturer used to ensure efficiency photon decfection is constant across an surface of collimated detector . -30-100 mil . counts defeciency causes ring artifact in SPECT Imaging Jaszczak SPECT Phantom test - Jaszczak determines 3D contrast , resolut von , & uniformity of SPECT camera . - 30mil.counts Combined SPECT CT QC Includes all QC + Registration attenuation correction accuracy or mis registration consequences SPECT QC NMTCB SPECT / CT QC 1. Peak 2. uniformity 3. Resolution 4. Untarity 5. High Count extrinsic floodfield uniformity Correction B 6 COR Dopamos 7. Jaszczak 8.Source strength 9.Transmission source mechanics Energy Peak confirm the camera is counting Photon in the Proper energy Windows . -Transmission source mechanics confirm operation of the source Shutter & translating mechanics , & reference blank transmission Scan should be acquired . Weekly ( preferably daily) SPECT / CT X - ray based NMTCB QC - all spect / CT QC including CT QC 1.Calibration 2.field uniformity Calibration CT number inserted Phantom L considerd not calibrated if error is greater than 5 Hounsfield units Field uniformity ensures uniform response throughout FOV - Brain Perfusion raphas Rapha Team Exametazine ECD , Dicisate , Cretec HMPAO Brain perfusion dose 10-20mCi Brain perfusion Indications 1. cerebrovascular disease - acute stroke transient ische - mic attacks 2. Dementia - Alzheimer's disease , multi - infarct dementia 3. Psychiatric disorder - affective disorder ( depre && Von Schizophrenia 4. Seizure disorder - idenification & location of focal epilepsy sites 5. Head Trauma ( cerebral brain death ) Brain perfusion imaging time 15-20min post injection (preferably @ 45min) Brain cross sections Mans axial Coronal sagital PET Oncology rapha F18- FDG FDG -F18 dose 5-20mCi intravenously FDG -F18 pt questions Pt History , surgenes , chemo radiation therapy , previous Imaging results , Pt . cooperation lying still for hrs & arms up . Laxative may given night before to prevent bowel inter ferring Blood Glucose Less than 200mcg Bone pain associated w / metastatic bone disease raphas Sr 89 Sm 153 P32 ST89 Chloride half life 50.5day ST89 Chloride analog -calcium analog cleared from blood stream & localizes in bont SR89 Chloride localization -localizes in areas of active osteogenesis in metastatic Sites longer than in normal bone -Sr 89 dose 40-60uCi & repeat dose @ 12 weeks Moving a pt from wheelchair to bed; wheelchair is in what degree 45° Filters that get rid of star artifact

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Bestzone Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
181
Member since
4 year
Number of followers
111
Documents
5004
Last sold
1 month ago
STUDY EXAMS AND STUDY GUIDES SUMMARIES ESSAY ALL VERIFIED

WELCOME!!!

3.9

27 reviews

5
13
4
4
3
6
2
2
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions