Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

ARMY ELECTRICAL EXPLOSIVES SAFETY /AMMO28/ EXAM LATEST ACTUAL EXAM 135 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES ANSWERS ALREADY GRADED A+

Rating
-
Sold
-
Pages
12
Grade
A+
Uploaded on
04-01-2024
Written in
2023/2024

ARMY ELECTRICAL EXPLOSIVES SAFETY /AMMO28/ EXAM LATEST ACTUAL EXAM 135 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES ANSWERS ALREADY GRADED A+ Which two publications provide detailed information on lightning protection systems? - CORRECT ANSWER-DA PAM 385-64 NFPA 780 Which statements about lightning protection are true?Select all that apply. - CORRECT ANSWER-Lightning can detonate munitions and explosives. Lightning seeks the path of least resistance to ground. Lightning cannot be stopped or prevented. Which statement is true about a mast LPS? - CORRECT ANSWER-Each mast must have two paths to ground. A 30-foot tall building is protected by a catenary system. How far from the building should the masts be placed? - CORRECT ANSWER-at least 6 feet Which LPS uses air terminals and conductors mounted directly to the structure? - CORRECT ANSWER-Integral Why does the wooden mast have an air terminal on top and two down conductors running its entire length? - CORRECT ANSWER-The wooden mast is not electrically conductive Which of the following is NOT a requirement for air terminals? - CORRECT ANSWER-Air Terminals must be at least 6 feet tall. During the inspection, John's team logged a discrepancy for this air terminal. Why? - CORRECT ANSWER-The air terminal is not attached to a conductor. How many down conductors are required for a building with a perimeter length of 325 feet? - CORRECT ANSWER-4 While conducting an LPS inspection, you see mast down conductors routed as shown in the image below. Do you write it up as a discrepancy? Why or why not? - CORRECT ANSWER-Yes, because mast down conductors should be 180 degrees apart. A steel beam, connected to the main LPS at its upper and lower extremities, is used as a down conductor. At what intervals should it be connected to the grounding system? - CORRECT ANSWER-60 feet or less Which statement about grounding systems is true? - CORRECT ANSWER-The resistance should be 25 ohms or less. Which of the following statements regarding bonding are true? Select all that apply. - CORRECT ANSWER-Bonding reduces the threat of sideflash by providing a low impedance path to ground. Bonding is a way of connecting LPS conductors to grounded metal objects. When should a grounded metal object be considered for bonding? - CORRECT ANSWER-When it's within 6 feet of a conductor Which bonding method is the most permanent and secure? - CORRECT ANSWER-Exothermic weld Which factors are used to calculate bonding distance?Select all that apply. - CORRECT ANSWER-Height of proposed bond Flashover medium Number of down conductors While conducting the inspection, John's team noticed a new metal light pole installed 3 feet from the down conductor at the corner of this building. They logged a discrepancy. Why? - CORRECT ANSWERBecause grounded metal objects within 6 feet of LPS conductors should be bonded to it Which types of information does an LPS record provide? Select all that apply. - CORRECT ANSWER-Test locations Test item descriptions or listing Type of test Responsibilities for conducting and administering the test plan Which section of DA PAM 385-64 provides LPS visual inspection guidance? - CORRECT ANSWER-Appendix D How often is a visual inspection required on an LPS? - CORRECT ANSWER-Every 12 months While conducting the LPS inspection, the team saw these surveillance cameras. Does this building comply with LPS standards? - CORRECT ANSWER-No, because the surveillance cameras are outside the zone of protection. How long must LPS test results be kept on file? - CORRECT ANSWER-6 inspection cycles How often is a conductive floor electrical test required in an ESDsensitive operating facility? - CORRECT ANSWER-Every 6 months For best accuracy, how many individual resistance tests are recommended for a conductive floor? Refer to DA PAM 385-64, Section C-3 as required. - CORRECT ANSWERTen test: Five electrode-to-electrode tests and five electrode-to-ground tests This conductive floor was tested at five locations. The average resistance of the electrode-to-electrode test was 55,871 ohms. Does this test pass? Refer to DA PAM 385-64, Section C-3. - CORRECT ANSWER-Yes, because an average resistance of 55,871 ohms is within standards How often is a 3-point fall-of-potential earth resistance test required on an LPS? - CORRECT ANSWER-Every 24 months When conducting a 3-point fall-of-potential earth resistance test on an integral LPS, how far from the ground rod should you place the C2 and P2 test probes? Refer to DA PAM 385-64, Table B-1 as required. Select one response for the C2 probe distance and one response for the P2 probe distance. - CORRECT ANSWER-C2 probe at 131 feet P2 probe at 82 feet

Show more Read less
Institution
ARMY ELECTRICAL EXPLOSIVES SAFETY /AMMO28/
Course
ARMY ELECTRICAL EXPLOSIVES SAFETY /AMMO28/









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ARMY ELECTRICAL EXPLOSIVES SAFETY /AMMO28/
Course
ARMY ELECTRICAL EXPLOSIVES SAFETY /AMMO28/

Document information

Uploaded on
January 4, 2024
Number of pages
12
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • army electrical
$12.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
caro254

Get to know the seller

Seller avatar
caro254 Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
2 year
Number of followers
1
Documents
185
Last sold
2 year ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions