Fire Inspector II Questions and Answers Already Solved The three E's of fire prevention? Engineering to eliminate hazards Educating the public Enforcing the codes Fire Inspection Visual inspection of a building and its property that is conducted to determine if the building complies with all pertinent statutes and regulations of the jurisdiction. 4 common roles an inspector may assume? Fire Marshal Fire Investigator Fire and Life safety education specialist Fire Protection engineer Standard for Professional Qualifications for Fire Inspector and Plan Examiner NFPA 1031 Fire Inspector 1 conducts basic fire inspections and applies codes and standards. Fire Inspector II Conducts most types of inspections and interprets applicable codes and standards. Standard is a document in which specifications or requirements defining the minimum levels of performance, protection or construction. Code rule or law established for enforcement of a fire protection, life safety, building construction or property maintenance issue. Model Code Organizations National Fire Protection Association(NFPA) International Code Council American Society of Mechanical Engineers Prescriptive Code list the specific details the installation or construction must meet. Performance based code outlines a requirement that a design had to meet, but does not state a particular method that must be use to meet the requirement. Permit document stating compliance with or restrictions for use based upon applicable codes. Permit types -use and occupancy permit -special use permit -fire protection equipment permit -hazardous materials permit NFPA 220 Standard on Types of Building Construction Type 1 construction is the most fire-resistive category of building construction. Used for buildings designed for large numbers of people, buildings with high life safety hazard, tall buildings, large area buildings and buildings with special hazards. Type 1 contstuction Structure must be constructed or protected so that there are at least 2 hours of fire resistance. Type 1 buildings typically use reinforced concrete and protected steel construction. Type II construction all components must be made of noncombustable materials....however are less stringent than type 1. Steel is the most common structural material in type II building
Written for
- Institution
- Fire Inspector II
- Course
- Fire Inspector II
Document information
- Uploaded on
- December 19, 2023
- Number of pages
- 25
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
fire inspector ii questions and answers already so
Also available in package deal