100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ACI Concrete Field-Testing Technician - Grade I Question with Correct Answers 100% Verified

Rating
-
Sold
-
Pages
11
Grade
A+
Uploaded on
12-10-2023
Written in
2023/2024

ACI Concrete Field-Testing Technician - Grade I Question with Correct Answers 100% Verified The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - Correct Answer 3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - Correct Answer 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. - Correct Answer Annually, accuracy The temperature of concrete may be measured in a wheelbarrow. True or False? - Correct Answer True The temperature of concrete may be measured in a wall form. True of False - Correct Answer True A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature. True of False? - Correct Answer False What must be done to the sample container prior to sampling the concrete? - Correct Answer Dampen (with water) What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete. - Correct Answer Gently press the concrete around the temperature measuring device at the surface of the concrete How long must the temperature measuring device remain in the freshly mixed concrete? - Correct Answer At least 2 minutes but not more than 5 minutes After the temperature of the concrete is read, what is required? - Correct Answer Reporting of temperature The temperature of concrete is reported to the nearest _____ degrees F [_____ C] - Correct Answer 1 degree F [0.5 C] According to ASTM C1064, what is one reason to take the temperature of concrete? - Correct Answer Verify conformance to a specified requirement for temperature of concrete A maximum temperature of freshly mixed concrete is specified in ASTM C1064. True of False? - Correct Answer False The sample of

Show more Read less
Institution
ACI
Course
ACI









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ACI
Course
ACI

Document information

Uploaded on
October 12, 2023
Number of pages
11
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Winfred West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
751
Member since
3 year
Number of followers
473
Documents
7324
Last sold
2 days ago
StudySmart

Revising without a good structure can be so frustrating but with StudySmart you are able to get revision questions, summary notes and exams to help you pass with flying colors

3.9

154 reviews

5
75
4
28
3
26
2
8
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions