Fire Inspector 1 Study Questions with 100% Correct Solutions| Rated A+
Correct Solutions| Rated A+ What is the minimum acceptable residual pressure in a water supply system that must be available for firefighting? - 20 psi What type of sprinkler system is a type of dry system that, when activated, flows water from all heads at the same time because all of the heads are open? - deluge What is the starting point used to measure travel distance to an exit? - the most remote point subject to occupancy How many sleeping accommodations are required for an occupancy to be classified as a hotel? - 16 What are examples of exit lighting that is required in many occupancies? - emergency lighting to illuminate means of egress An extinguisher designed for Class A fires carries which color and shape symbol? - green triangle During which phase of a fire does flashover usually occur? - fully develped What are the states of matter? - solid, liquid, gas What are the four phases of fire development in their correct order? - incipient, growth, fully developed, decay Two common file folder formats used in the organization of fire inspection records are chronological and ___________. - functional The purpose of the NFIRS is to collect useful national data on the many underlying factors in a fire. - true What material is inherently fire resistive? - masonry What designation of fire door would be required for use as part of a fire wall? - A How many different types of fire loads does a Type III construction have - 2 What NFPA 13 hazard class includes occupancies that may produce severe fires - extra hazards How many general categories of fire are there? - 5 Since steel conducts heat well, it will tend to do what as temperature exposure increases? - expand and loose strength In addition to activating the fire alarm and detection system, which other action will a duct-detector perform? - shut down the air-handling system if it detects smoke What is the fire department connection (FDC)? - a connection where the FD can pump water into a sprinkler or standpipe system What assemblies of pieces of wood or wood-and-metal combinations often used to support floors and roofs? - wood trusses What is an area of refuge in relationship to an exit from a building? - a protected area designed for use by people with mobility impairements What fire alarm and detection system component is either an automatic or manually operated device that, when activated, causes the system to indicate an alarm? - alarm initiation device What type of glass is manufactured so that a thin sheet of plastic is placed between two sheets of glass? - laminated glass When a building has an automatic fire sprinkler system, what must you make sure the system is matched to perform against? - content hazard level What NFPA standard governs the standard for portable fire extinguishers? - 10 How thick can wood posts in a heavy timber constructed building be? - 8" or larger A gravity vent is part of which system in a building? - smoke management Wood and metal furnishings, paper, and office supplies are which content hazard level? - ordinary Found throughout a building, which building material is rarely used for structural support? - plastic What is the name of the measurement device used to test water flow from a hydrant? - pitot gauge What type of sprinkler system requires a secondary device to activate, such as a smoke detector, before water will be released into the piping system? - preaction What type of fire inspection occurs to ensure compliance with fire code during and at the end of a building's construction? - construction Glass is ___________, but it is not _________. - noncombustible, fire resistive What type of plan set shows the overview of the lot that is being reviewed? - site How many specific occupancy groupings are recognized by NFPA standards? - 15 What part of a building's construction bears the weight of the entire structure? - foundation Extension cords are considered to be permanent wiring systems. - false What NFPA 13 hazard class includes occupancies that are ordinary, mercantile, manufacturing, and industry properties and that are placed into one of two groups? - ordinary hazards What type of construction feature supports other beams? - girder What NFPA code is the most widely used to determine building construction classification? - 220 What are two common causes of electrical fires? - arcing and overheating When would a variance or appeal be applicable in plan review? - when a project cannot conform to a section of code
Geschreven voor
- Instelling
- Fire Inspector 1
- Vak
- Fire Inspector 1
Documentinformatie
- Geüpload op
- 11 oktober 2023
- Aantal pagina's
- 13
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
Ook beschikbaar in voordeelbundel