Written in
2023/2024

Fire protection for a new construction sleeping suite not exceeding 7500 sqft - Answer-The room must have a sprinkler system and complete smoke detection OR sprinkler system with QRS or residential sprinklers Fire protection for a new construction sleeping suite greater than 7500 sqft - Answer-The room mush have direct supervision AND total coverage automatic smoke detection and sprinkler system protection with QRS or residential sprinkler Fire protection for existing construction not exceeding 5000 sqft. - Answer-The room must have automatic smoke detection Fire protection for existing construction up to 10,000 sqft - Answer-Additional fire protection - Sprinkler protection and smoke partitions. Fire protection for a non sleeping suite up to 12,500 sqft - Answer-The facility must have either quick response sprinklers or completed smoke detection Fire protection for a non sleeping suite up to 15,000 sqft. - Answer-The facility must have BOTH quick response sprinklers and complete smoke detection Where can you store up to 300 cubic feet of medical gas (12 E Cylinders) - Answer- They can be stored in a smoke zone without seperation. Fire protection for a medical gas storage room with 300 cubic feet to 3000 cubic feet worth of Medical Gas - Answer-It is permitted in a non rated room with sprinkler protection and clearance from combustibles Fire protection for a medical gas storage room with greater than 3000 cubic feet worth of Medical Gas - Answer-Permitted in 1 hour FRR enclosure with vents A hospital and a business occupancy can be separated by this FRR - Answer-2 hour FRR A ambulatory care facility and a business occupancy can be separated by this FRR - Answer-1 hour FRR How far can a space be in a room from a exit corridor - Answer-100 feet (Please note that it has to be 150/200 feet from the actual exit or smoke door) How far can a space be in a room from a exit or smoke compartment door. - Answer- 200 feet if sprinklered 150 feet if non sprinklered What FRR does linen and waste collection rooms required in Hospitals - Answer-1 hour FRR If a healthcare facility is above a business occupancy what do they need to be separated by? - Answer-1 hour FRR between the healthcare and business floors If a healthcare facility is above a mechanical equipment room what do they need to be separated by? - Answer-2 hour FRR between the healthcare and business floors What is the minimum ceiling height in patient areas? - Answer-7' 10" What is the minimum ceiling height in corridors - Answer-7' 6" What is the minimum required corridor in patient areas? - Answer-8 feet What is the minimum required corridor in non patient areas? - Answer-44 inches or 3.6666 feet What is the required distance from a sprinkler to an obstruction - Answer-18 inches A vertical exit connects 3 or less stories. What type of FRR does it need - Answer-1 hr FRR A vertical exit connects 4 or more stories. What type of FRR does it need - Answer-2 hr FRR and must be supported by a structure having not less than a 2 hr FRR What are the FRR for a horizontal exit? - Answer-2 hr FRR and at least one exit can not be horizontal What are the smoke compartment rules regarding a story used by inpatients for sleeping or treatment - Answer-The smoke compartment must be separated into two or more smoke compartments. What is the maximum size for a smoke compartment - Answer-22,500 sqft What are the smoke compartment rules regarding a story used by 50 or more patients - Answer-The smoke compartment must be separated into two or more smoke compartments. What FRR and door status must a new construction hazard room have that is greater than 100 sqft have? - Answer-1 hr FRR and door closures What FRR and door status must a new construction hazard room have that is between 50 sqft and 99 sqft? - Answer-No FRR but must have door closures What FRR must an existing hazard room have that is 50 sqft or greater? - Answer-1 hour FRR barrier

Show more Read less
Institution
CHC
Course
CHC











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
CHC
Course
CHC

Document information

Uploaded on
September 30, 2023
Number of pages
93
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Reviews from verified buyers

Showing all reviews
10 months ago

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Clayjohnson California State University - Channel Islands
View profile
Follow You need to be logged in order to follow users or courses
Sold
81
Member since
2 year
Number of followers
19
Documents
1922
Last sold
1 week ago
A+ revision material

A+ Revision Material refers to educational content and resources designed to help students prepare for and excel in their academic assessments, particularly A+ graded exams or courses. These materials typically include study guides, practice exams, flashcards, and other resources that condense and simplify complex subject matter to aid in effective revision. They are created to enhance a student's understanding of the material, reinforce key concepts, and improve their chances of achieving top grades. A+ Revision Material is commonly used by students at various levels of education, from high school to college and beyond, to boost their knowledge and confidence before important examinations.

Read more Read less
4.9

195 reviews

5
187
4
1
3
2
2
1
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions