Installatie 7
Projectgroep: 22
fase: Schetsontwerp fase
Datum: 27 februari
Status: Definitief
Opdrachtgever: HAN University of Applied Sciences
Adviseur: P.A. Bakker | N.J. Geelen | H.B. Glastra | R.A.J. Haagsma | L. Seegers
, Pagina 2 van 33
Inhoudsopgave
Inhoudsopgave............................................................................................................................ 2
1. Analyse fase............................................................................................................................ 3
1.1 Opdracht A1....................................................................................................................... 3
1.2 Opdracht A2....................................................................................................................... 4
1.3 Opdracht A3....................................................................................................................... 5
1.4 Opdracht A4....................................................................................................................... 6
1.5 Opdracht A5....................................................................................................................... 7
1.6 Opdracht A6....................................................................................................................... 8
1.6.1 Inleiding........................................................................................................................ 8
1.6.2 Voorbereiding............................................................................................................... 8
1.6.3 Meetopstelling & meetapparatuur................................................................................9
1.6.4 (bespreken) meetresultaten......................................................................................... 9
1.6.5 Bepalen PMV en PPD..................................................................................................10
1.6.6 Vergelijking resultaten & conclusie............................................................................10
1.6.7 Aanbeveling................................................................................................................ 10
2. Schetsontwerpfase................................................................................................................ 11
2.1 De brug............................................................................................................................ 11
2.1.1 Ruimtelijk ontwerp..................................................................................................... 11
2.1.2 Systeemindicatie........................................................................................................ 13
2.1.3 Warmteverlies............................................................................................................ 14
2.1.4 Verwarmingsafgiftesysteem.......................................................................................15
2.1.5 Mogelijkheden NOM.................................................................................................... 16
2.2 Uitpandige uitbreiding...................................................................................................... 17
2.2.1 Ruimtelijk ontwerp..................................................................................................... 17
2.2.2 Systeemindicatie........................................................................................................ 19
2.2.3 Afmetingen Technische Ruimte..................................................................................20
2.2.4 Warmteverlies............................................................................................................ 22
2.2.5 Warmteafgiftesysteem............................................................................................... 23
2.2.6 Plattegrondtekening................................................................................................... 24
2.2.7 Koellast....................................................................................................................... 25
2.2.8 Ontwerpaspecten....................................................................................................... 26
Bijlage I: Uitgangspunten & berekeningen luchttoevoer............................................................29
Bijlage II: tabellen systeemkeuze............................................................................................... 30
Bijlage III: tabellen bepaling TR.................................................................................................. 32
, 1. Analyse fase
1.1 Opdracht A1
In onderstaand bestand zullen wij een overzicht geven van de door ons bepaalde E- & W-Installaties die aanwezig zijn op de tweede
verdieping. In onderstaande tabel (Tabel A1) hebben wij in de eerste kolom aangegeven of het een E- of W-Installatie is. In de tweede, derde
en vierde kolom staat in het zwart aangegeven welk onderdeel we hebben gevonden, en in het rood wat er bij dit onderdeel komt kijken. Ook
hebben wij in deze tweede, derde en vierde kolom aangegeven of het onderdeel opwek, transport of afgifte is. Als laatste hebben wij
aangegeven in welke ruimte(-s) de installatiesoorten zich bevinden.
Installatie soort: E/W Opwek Transport Afgifte Ruimte Ruimte 2 Ruimte Ruimte 4
1 3
Verwarmings installatie W - Leiding Radiator X X X X
Verlichtings installatie E - Kabels / bedrading Armatuur X X X X
Sanitair installatie W - Leiding Kraan/ wastafel X X - -
Ventilatie installatie W Rooster Plenum / kanaal Schacht - X X X
Ventilatie installatie W - Studielandschap Susbox - X X -
Sanitair installatie W - Rioleringsbuis Toilet/ Urinoir X - - -
Elektrische installatie E - Kabels/ bedrading Wandcontactdoos - X X X
Beveiligingsinstallatie W - Kabels/ bedrading Alarm/ beveiliging - X X X
Brandbeveiligingsinstallatie W - Waterslang Brandblusser - - - X
Brandbeveiligingsinstallatie E - Kabels/ bedrading Rookmelder X X X X
Communicatie installatie E - Kabels/ bedrading Intercom/ microfoon - X X X
Noodverlichtingsinstallatie E - Kabels/ bedrading Noodverlichting - - - X
Tabel 1A: Ruimte 1 is de toiletruimte. Ruimte 2 zijn de vaklokalen. Ruimte 3 zijn de kantoorruimten/ lerarenruimtes. Ruimte 4 is het
studielandschap/ verkeersruimte.
Processchema:
De lucht wordt door een luchtbehandelingskast naar binnen gezogen (aanwezig op de derde verdieping, in de technische ruimte). Vanuit het
studielandschap word de lucht d.m.v. susboxen getransporteerd naar de lokalen, kantoren, vergaderruimten en toiletten. Dit gebeurt door
middel van overstroom. Nadat de lucht in deze ruimten is geweest, wordt het door roosters in het plafond afgezogen naar het plenum. Deze
transporteert de lucht naar luchtbehandelingskasten in de technische ruimte. Vanuit de technische ruimte wordt de lucht uiteindelijk weer
naar buiten getransporteerd door middel van aanwezige ventilatoren.
, Pagina 4 van 33
1.2 Opdracht A2
Projectgroep: 22
fase: Schetsontwerp fase
Datum: 27 februari
Status: Definitief
Opdrachtgever: HAN University of Applied Sciences
Adviseur: P.A. Bakker | N.J. Geelen | H.B. Glastra | R.A.J. Haagsma | L. Seegers
, Pagina 2 van 33
Inhoudsopgave
Inhoudsopgave............................................................................................................................ 2
1. Analyse fase............................................................................................................................ 3
1.1 Opdracht A1....................................................................................................................... 3
1.2 Opdracht A2....................................................................................................................... 4
1.3 Opdracht A3....................................................................................................................... 5
1.4 Opdracht A4....................................................................................................................... 6
1.5 Opdracht A5....................................................................................................................... 7
1.6 Opdracht A6....................................................................................................................... 8
1.6.1 Inleiding........................................................................................................................ 8
1.6.2 Voorbereiding............................................................................................................... 8
1.6.3 Meetopstelling & meetapparatuur................................................................................9
1.6.4 (bespreken) meetresultaten......................................................................................... 9
1.6.5 Bepalen PMV en PPD..................................................................................................10
1.6.6 Vergelijking resultaten & conclusie............................................................................10
1.6.7 Aanbeveling................................................................................................................ 10
2. Schetsontwerpfase................................................................................................................ 11
2.1 De brug............................................................................................................................ 11
2.1.1 Ruimtelijk ontwerp..................................................................................................... 11
2.1.2 Systeemindicatie........................................................................................................ 13
2.1.3 Warmteverlies............................................................................................................ 14
2.1.4 Verwarmingsafgiftesysteem.......................................................................................15
2.1.5 Mogelijkheden NOM.................................................................................................... 16
2.2 Uitpandige uitbreiding...................................................................................................... 17
2.2.1 Ruimtelijk ontwerp..................................................................................................... 17
2.2.2 Systeemindicatie........................................................................................................ 19
2.2.3 Afmetingen Technische Ruimte..................................................................................20
2.2.4 Warmteverlies............................................................................................................ 22
2.2.5 Warmteafgiftesysteem............................................................................................... 23
2.2.6 Plattegrondtekening................................................................................................... 24
2.2.7 Koellast....................................................................................................................... 25
2.2.8 Ontwerpaspecten....................................................................................................... 26
Bijlage I: Uitgangspunten & berekeningen luchttoevoer............................................................29
Bijlage II: tabellen systeemkeuze............................................................................................... 30
Bijlage III: tabellen bepaling TR.................................................................................................. 32
, 1. Analyse fase
1.1 Opdracht A1
In onderstaand bestand zullen wij een overzicht geven van de door ons bepaalde E- & W-Installaties die aanwezig zijn op de tweede
verdieping. In onderstaande tabel (Tabel A1) hebben wij in de eerste kolom aangegeven of het een E- of W-Installatie is. In de tweede, derde
en vierde kolom staat in het zwart aangegeven welk onderdeel we hebben gevonden, en in het rood wat er bij dit onderdeel komt kijken. Ook
hebben wij in deze tweede, derde en vierde kolom aangegeven of het onderdeel opwek, transport of afgifte is. Als laatste hebben wij
aangegeven in welke ruimte(-s) de installatiesoorten zich bevinden.
Installatie soort: E/W Opwek Transport Afgifte Ruimte Ruimte 2 Ruimte Ruimte 4
1 3
Verwarmings installatie W - Leiding Radiator X X X X
Verlichtings installatie E - Kabels / bedrading Armatuur X X X X
Sanitair installatie W - Leiding Kraan/ wastafel X X - -
Ventilatie installatie W Rooster Plenum / kanaal Schacht - X X X
Ventilatie installatie W - Studielandschap Susbox - X X -
Sanitair installatie W - Rioleringsbuis Toilet/ Urinoir X - - -
Elektrische installatie E - Kabels/ bedrading Wandcontactdoos - X X X
Beveiligingsinstallatie W - Kabels/ bedrading Alarm/ beveiliging - X X X
Brandbeveiligingsinstallatie W - Waterslang Brandblusser - - - X
Brandbeveiligingsinstallatie E - Kabels/ bedrading Rookmelder X X X X
Communicatie installatie E - Kabels/ bedrading Intercom/ microfoon - X X X
Noodverlichtingsinstallatie E - Kabels/ bedrading Noodverlichting - - - X
Tabel 1A: Ruimte 1 is de toiletruimte. Ruimte 2 zijn de vaklokalen. Ruimte 3 zijn de kantoorruimten/ lerarenruimtes. Ruimte 4 is het
studielandschap/ verkeersruimte.
Processchema:
De lucht wordt door een luchtbehandelingskast naar binnen gezogen (aanwezig op de derde verdieping, in de technische ruimte). Vanuit het
studielandschap word de lucht d.m.v. susboxen getransporteerd naar de lokalen, kantoren, vergaderruimten en toiletten. Dit gebeurt door
middel van overstroom. Nadat de lucht in deze ruimten is geweest, wordt het door roosters in het plafond afgezogen naar het plenum. Deze
transporteert de lucht naar luchtbehandelingskasten in de technische ruimte. Vanuit de technische ruimte wordt de lucht uiteindelijk weer
naar buiten getransporteerd door middel van aanwezige ventilatoren.
, Pagina 4 van 33
1.2 Opdracht A2