100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NATE Gas Heating Exam Verified Questions and answers 2023 Latest Update

Rating
-
Sold
-
Pages
14
Grade
A+
Uploaded on
11-09-2023
Written in
2023/2024

NATE Gas Heating Exam Verified Questions and answers 2023 Latest Update Since 1992, the United States Department of Energy has required that all furnaces sold and installed from that date on must have an AFUE of no less than: A: 70% B: 75% C: 78% D: 80% - correct answer C: 78% Many pre-1992 furnaces have efficiencies around . A: 10% B: 40% C: 60% D: 80% - correct answer C: 60% Today, furnaces with AFUE ratings greater than are available. A: 85% B: 90% C: 100% D: 110% - correct answer B: 90% A thermocouple is used with: A: Intermittent pilot systems B: Direct spark ignition systems C: Glow coil ignition systems D: Standing pilot ignition systems - correct answer D: Standing pilot ignition systems The purpose of the gas pressure regulator is to: A: Keep the color of the flame constant B: Keep the high limit switch from tripping C: Maintain a constant gas pressure at the burner D: Allow the gas valve to operate smoothly and accurately - correct answer C: Maintain a constant gas pressure at the burner The instrument used to measure outlet gas pressure is the: A: Velometer B:Anemometer C: Monometer D: Draft gauge - correct answer C: Monometer The regulator on a natural gas furnace should be adjusted to supply inches of pressure at the burners. A: 11" B: 10" C: 3.5" D: 2" - correct answer C: 3.5" Burning one cubic foot of natural gas releases approximately btu. A: 800 B: 1,050 C: 12,000 D: 15,000 - correct answer B: 1,050 and a burning temperature of degrees F. A: 800 degrees, 1000 degrees B: 1,100 degrees, 3,500 degrees C: 1,100 degrees, 5,000 degrees D: 2,500 degrees, 8,000 degrees - correct answer B: 1,100 degrees, 3,500 degrees Propane and butane are both: A: Lighter than air B: Heavier than air C: Weigh the same as air D: None of the above - correct answer B: Heavier than air In order to achieve complete combustion with natural gas, each cubic foot of gas must combine with no less than cubic feet of air with an additional 5 cubic feet of extra air to ensure there is enough oxygen for complete combustion. A: 5 cubic feet B: 10 cubic feet C: 15 cubic feet D: 20 cubic feet - correct answer B: 10 cubic feet The three elements of combustion are: A: Fuel, oxygen and ignition B: Nitrogen, oxygen and heat C: Air, fuel and oxygen D:Air, fuel and nitrogen - correct answer A: Fuel, oxygen and ignition Which of the following is a natural result of combustion? A: Water vapor B: Carbon monoxide Under ideal conditions natural gas has an ignition temperature of degrees F C: Carbon dioxide D:All of the above - correct answer A: Water vapor Primary air is air that: A: Is mixed with the fuel before the fuel reaches the burner B: Is mixed with the fuel at the burner after the fuel has ignited C: Remains unused after the combustion process is complete D: Enters the draft diverter and goes up the stack with the products of combustion - correct answer A: Is mixed with the fuel before the fuel reaches the burner Secondary air is air that: A: Is mixed with the fuel before the fuel reaches the burner B: Is mixed with the fuel at the burner after the fuel has ignited C: Remains unused after the combustion process is complete D: Enters the draft diverter and goes up the stack with the products of combustion - correct answer B: Is mixed with the fuel at the burner after the fuel has ignited The three major furnace configurations are: A: Up-flow, down-flow and lowboy B: Up-flow, down-flow and horizontal C: Up-flow, down-flow and cross-flow D: None of these is correct - correct answer B: Up-flow, down-flow and horizontal Residential gas furnaces use blowers powered by which types of motors? A: Poly-phase, two phase, single phase and capacitor start B: Shaded pole, split-phase, capacitor start and PSC C: Three phase, shaded pole and PSC D: Split-phase, induction start-induction run and variable speed DC - correct answer D: Split-phase, induction start-induction run and variable speed DC The horsepower range of residential heating blower motors is: A: 1⁄8 to 1⁄16 hp B: 1⁄4 to 1⁄2 hp C: 1⁄2 to 2 hp D: 3⁄4 to 2 hp - correct answer B: 1⁄4 to 1⁄2 hp A heat anticipator is wired: A: In series with the "W" terminal B: In parallel with the "W" terminal C: In series with the "R" terminal D: In parallel with the "R" terminal - correct answer A: In series with the "W" terminal Placing a jumper wire between the "R" terminal and the "G" terminal on a thermostat subbase will energize the: A: Gas valve B: Indoor fan motor C: Outdoor fan motor D: Compressor - correct answer B: Indoor fan motor Placing a jumper wire between the "R" terminal and the "W" terminal on a thermostat sub-base will energize the: A: Gas valve B: Indoor fan motor C: Outdoor fan motor D: Compressor - correct answer A: Gas valve Carbon monoxide is a: A: Product of incomplete combustion B: Poisonous gas C: Odorless gas D:All of the above are correct - correct answer D:All of the above are correct The chemical symbol for carbon monoxide is: A: CO2 B: CO C: H2O D: NH3 - correct answer B: CO Selecting a lower speed tap setting on a furnace indoor blower motor will cause: A: The temperature rise through the furnace to increase B: The temperature rise through the furnace to decrease C: The temperature rise through the furnace will not be affected D: The furnace to act as a humidifier - correct answer A: The temperature rise through the furnace to increase "Carry over" channels or "cross overs" are used to: A: Carry unused excess fuel back to the flue where it is sent up the stack B: Carry primary air to the heat exchanger C: Carry secondary air to the heat exchanger D: Carry the flame from the first burner that lights to the remaining burners - correct answer D: Carry the flame from the first burner that lights to the remaining burners Modern high-efficiency burners use combustion blowers. What are the two major types of combustion blowers? A: Induced draft and forced draft B: High pressure and low pressure C: Impeller type and centrifugal type D: Liquid and vapor types - correct answer A: Induced draft and forced draft The purpose of the combustion blower is to: A: Cause an adequate amount of oxygen-rich air to mix with the fuel for better combustion B: Push the products of combustion out of the building C: Prevent carbon monoxide from entering the heat exchanger D: Give the larger blower motor a rest - correct answer A: Cause an adequate amount of oxygen-rich air to mix with the fuel for better combustion Heat transfers from an object or area at a higher temperature to an object or area at a lower temperature. A heated heat exchanger transfers heat to the air by: A: Conduction B: Natural convection C: Radiation D: Forced convection - correct answer D: Forced convection The voltage that creates a spark on a spark ignition system is approximately: A: 240 volts B: 5,000 volts C: 15,000 volts D: 25,000 volts - correct answer C: 15,000 volts The capacity of a natural gas furnace is de-rated by for every 1000 feet above sea level: A: 1% B: 2% C: 3% D: 4% - correct answer D: 4% A crack in a heat exchanger can: A:Allow combustion gases to mix with the space air B: Prevent the heat from effectively transferring to the air C: Cause the high-limit control to shut the furnace down D: Cause the furnace to catch on fire - correct answer A: Allow combustion gases to mix with the space air Gas valves operate on what voltage? A: 12 volts B: 24 volts C: 120 volts D: 230 volts - correct answer B: 24 volts Mid-efficiency furnaces operate with flue gas temperatures between: A: 275 and 360 degrees B: 200 and 500 degrees C: 100 and 275 degrees D: 80 and 100 degrees - correct answer A: 275 and 360 degrees High-efficiency furnaces operate with flue gas temperatures between: A: 275 and 360 degrees B: 200 and 500 degrees C: 100 and 275 degrees D: 80 and 100 degrees - correct answer C: 100 and 275 degrees "B" vent is: A: Hard, inflexible white plastic vent tubing able to withstand temperatures up to 325 degrees F B: Hard, inflexible white plastic vent tubing able to withstand temperatures up to 400 degrees F C: Single wall sheet metal vent pipe D: Double wall sheet metal vent pipe - correct answer D: Double wall sheet metal vent pipe Latent heat is: A: Heat that causes a change in temperature with no change in state B: Heat that causes a change in state with no change in temperature C: The large amount of heat involved when a gas condenses into a liquid D: Both b and c are correct - correct answer D: Both b and c are correct A mid-efficiency or high-efficiency furnace will not operate if: A: It is not grounded or the polarity is reversed B: The indoor blower motor capacitor is wired into the wrong motor winding C: The air filter is installed backwards D: The door switch is shorted closed - correct answer A: It is not grounded or the polarity is reversed Furnaces are placed into categories based upon: A: Venting characteristics B: Btuh capacity range C: Gas valve type D: Total airflow in CFM - correct answer A: Venting characteristics Condensing furnaces: A: Condense water vapor out of the air at the burner, thus increasing the efficiency of the burn B: Increase the combustion efficiency by adding condensed oxygen to the fuel C: Squeeze heat out of the flue gases by removing the latent heat of condensation causing much of it to liquefy D: None of the above is correct - correct answer C: Squeeze heat out of the flue gases by removing the latent heat of condensation causing much of it to liquefy Secondary heat exchangers: A: optional heat exchangers used when necessary B: constructed so return air passes over the secondary heat exchanger first and then over the main heat exchanger C: used to add more heat to the supply air before entering the sheet metal ducting system D: now rarely used on the higher efficiency furnaces - correct answer B: constructed so return air passes over the secondary heat exchanger first and then over the main heat exchanger A combination fan-stat and high limit: A:Are both safety controls B: Consists of a high temperature safety thermostat built into the wall thermostat C: Separate switches from a single helical bimetal, one switch controls the indoor fan, the other acting as safety control D: All the above are correct - correct answer C: Separate switches from a single helical bimetal, one switch controls the indoor fan, the other acting as safety control The three basic categories of ignition systems are: A: Continuous ignition, intermittent ignition and direct ignition B: Continuous ignition, direct ignition and manual ignition C: Automatic ignition, intermittent ignition and direct ignition D: Automatic ignition, direct ignition and indirect ignition - correct answer A: Continuous ignition, intermittent ignition and direct ignition The intermittent ignition system: A: Lights the burner directly B: Uses a thermocouple C: Lights the pilot only on a call for heat D: Is the most efficient ignition system - correct answer C: Lights the pilot only on a call for heat Direct ignition: A: Uses a spark or hot surface igniter to light the burner directly B: Gets its name from the fact that it is immediate, direct or fast acting C: Lights the pilot only on a call for ignition D: Is the most efficient ignition system - correct answer A: Uses a spark or hot surface igniter to light the burner directly The flame sensor: A: Is a thick ceramic rod that senses the heat of the flame and causes the rod to expand and signal the solid state flame board that a flame is present B: Is a small-diameter conducting rod that senses when a flame is present because a current flow moves between the rod and the burner when the flame creates an electrical path between them C: Is actually a metal-oxide diode that rectifies alternating current to direct current for the gas valve D: Is a device that shuts down the main gas valve if the burner flame gets out of control and starts burning outside the fire box or combustion chamber - correct answer B: Is a small-diameter conducting rod that senses when a flame is present because a current flow moves between the rod and the burner when the flame creates an electrical path between them Which of the following is a typical sequence of operation for a high efficiency condensing furnace? A: induced draft blower runs for 20 seconds, ignitor heats for 15 seconds, gas valve opens, burner lights off, flame sensor monitors the flame for the entire heating cycle until the thermostat is satisfied B: ignitor heats up for 15 seconds, gas valve opens and induced draft blower starts, burner lights and then flame sensor takes over monitoring until the thermostat is satisfied C: induced draft blower runs for 20 seconds, ignitor heats up for 15 seconds, gas valve opens, burner lights off and flame sensor monitors flame. Plenum heats up, blower pulls air over the heat exchanger D: None of these is correct, as condensing furnaces do not use induced draft blowers. - correct answer C: induced draft blower runs for 20 seconds, ignitor heats up for 15 seconds, gas valve opens, burner lights off and flame sensor monitors flame. Plenum heats up, blower pulls air over the heat exchanger A yellow burner flame is usually caused by: A:A weak ignitor B: Lack of sufficient air C: Low gas pressure D: Too much primary air - correct answer B: Lack of sufficient air A lifting burner flame is usually caused by: A:A new ignitor that has not been broken in B: High gas pressure and/or too much primary air C: Low gas pressure and/or not enough primary air D: Blockage in the flue - correct answer B: High gas pressure and/or too much primary air

Show more Read less
Institution
NATE Gas Heating
Course
NATE Gas Heating









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NATE Gas Heating
Course
NATE Gas Heating

Document information

Uploaded on
September 11, 2023
Number of pages
14
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
RNSTORE Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
493
Member since
3 year
Number of followers
382
Documents
825
Last sold
1 month ago

4.5

125 reviews

5
99
4
7
3
6
2
6
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions