Study Guide - Dell Client Advanced 2023 Verified
Study Guide - Dell Client Advanced 2023 Verified The Edge Gateway 3000 series support the following power sources: - 3-pin DC - In Power over Ethernet (PoE 37V DC-57VDC) Select the statements that are true about Trusted Platform Module (TPM) - The Trusted Platform Module (TPM) is used to generate and store Keys. It can create and store digital certificates. It can also be used to enable the BitLocker hard drive encryption. The OEM identity (ID) Module is a Utility used to replace the Dell Logo on the System Hardware like the Bezel. - False When the side cover of Precision Tower 7920 is not assembled, the system will still power on. - False ePSA stands for - Enhanced Pre-boot System Assessment Which RAID is defined as Striped set without Parity? - RAID 0 In a scenario where the System Board is replaced, remove the Processor Heatsink Module (PHM) together with the processor. There is no need to seperate the PHM from the processor. - True What steps must be taken if there is a fan-related error message displayed at the Start up but the system boots to the OS? - The Dell Precision System board is shipped in Manufacturing mode and the User or Service Provider must select the manageability option upon first boot after replacement. - True We Import a Foreign configuration in a RAID Array, if: - The array containing the foreign configuration is in an Offline state. Which indicator shows whether power is present or power fault has occurred in Precision systems? - Both Where can the field Service Manual containing Critical Callout, Disassembly and Reassembly instructions be found? - PRM/ Educate Dell The touchscreen LCD assembly for Alienware 13R3 is a Hinge-Up Design (HUD) assembly and cannot be further disassembled once it is removed from the chassis - True iDRAC with Lifecycle Controller can be used for - In the latest Precision Rack, the iDRAC Enterprise license is available by default - False USB Service Key is used for Windows OS Installation and debranding (for OEM) in an Edge Gateway - True Select all the LED codes for Memory related issues in a Dell Edge Gateway - 2,3 2,4 2,5 On a Precision Workstation, if a Hard drive status indicator flashes green, amber and then turns off; this indicates the drive is rebuilding - False A CAN (Controller Area Network) bus is a vehicle bus standard designed to allow micro controllers and devices to communicate with each other in applications without a host computer. - True In a PERC H730P controller, P stands for Performance - True DPK stands for - Digital Product Key After completing a service incident on a Precision Tower 7920, technician attempts to run ePSA before re-assembling the side cover. However, system is not able to power on and displays LED error code of 4-7. What could be the issue? - The intrusion switch is triggered and power is cut-off. Install the side cover to de-activate the intrusion switch. In general, an Anti-Static Mat is used to prevent Electrostatic damage - True Select all the guidelines that have been followed when working in a Data Center Environment - Only access racks that that contain the equipment you are assigned to troubleshoot. Communicate any problems to the Data Center staff. No food or drinks allowed in the Data Center. Which screwdriver is recommended for removing PHM (Processor Heat Sink module) used on a Precision Rack 7920? - Torx #T30 On Latitude 14 Rugged Extreme - 7414, which light is used to communicate error using single LED? - Battery Light
Written for
- Institution
- Dell Client Foundations
- Course
- Dell Client Foundations
Document information
- Uploaded on
- August 21, 2023
- Number of pages
- 3
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
study guide dell client advanced 2023 verified
Also available in package deal