100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Residential Wireman Electrical Exam 2023/2024 Graded A+

Beoordeling
-
Verkocht
-
Pagina's
10
Cijfer
A+
Geüpload op
01-08-2023
Geschreven in
2023/2024

The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper Ampacities, Grounding 250.122(B) Table 250.122 Table 8 Ch 9 - ANSWER-4 The continuity of the grounded conductor shall depend on a busbar or __ only. Continuity, Grounded conductors 200.12 - ANSWER-wire. Each multi-wire branch circuit shall be provided with a means that will ____ disconnect all ungrounded conductors at the point where the branch circuit originates. Disconnecting means, Branch circuits, multiwire 210.4(B) - ANSWER-Simultaneously Balconies, decks, and porches that are accessible from the inside of the dwelling unit shall have at least one receptacle not more than __ ft. above the balcony, deck, or porch surface. Balconies, outdoor, receptacles for, 210.52(E)(3) - ANSWER-6 1/2 Where it is impracticable to locate the service head above the point of attachment, the service head location shall be permitted not farther than ___ inches from the point of attachment. Service drops, Connections, service head 230.54 (C) Exception - ANSWER-24 True/False: One of the means by which grounding conductors and bonding jumpers shall NOT be connected by is machine screw type fasteners. Connection of Grounding and Bonding Equipment 250.8 - ANSWER-False Cables with entirely nonmetallic sheaths are permitted to enter the top of a surface-mounted enclosure through one or more nonflexible raceways not less than 450 mm (18 in.) and not more than __ feet in length Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - ANSWER-10 The maximum allowable overcurrent protection for four 14/2 NM cables installed in contact with thermal insulation without maintaining spacing between cables is: Nonmetallic-sheathed cable, Insulation, Ampacity, 334.112, 334.80 - ANSWER-15 What kind of protection is required for an outdoor receptacle located under the soffit of a dwelling for holiday lighting? Ground-fault circuit interrupters, Outdoors, dwelling units, 210.8(A)(3) - ANSWER-GFCI The minimum rating for a service disconnecting means for a building, other than a single family dwelling, consisting of three 2 wire circuits shall be__ amperes. Service equipment, Rating, 230.79(D) - ANSWER-60 Where ungrounded conductors are increased in size, equipment grounding conductors shall be increased in size ___. Grounding conductors, 250-III, Sizes, 250.122 250.122(B) - ANSWER-proportionately True/ False: Unless listed for the control of other loads, general use dimmer switches, shall only be used to control permanently installed incandescent luminaires. Dimmers, Switch 404.14(E) - ANSWER-True In what areas of a dwelling shall 125-volt, single phase, 15 and 20 ampere outlets not be required to be protected by an arc-fault circuit interupter? Dwellings, Arc-fault circuit-interrupter protection, 210.12(A) 210.12(A) - ANSWER-Hallways A ground ring encircling the building or structure, in direct contact with the earth, shall consist of at least 20 feet of bare copper conductor NOT smaller than __ AWG. Ground ring 250.52(A)(4) - ANSWER-2 The minimum size copper equipment grounding conductor required for a 15-ampere branch circuit installed in rigid metal conduit that supplies a swimming pool pump motor is __ AWG. Swimming pools, fountains, and similar installations, 680.21(A)(1) - ANSWER-12 The maximum allowable ampacity of 18 AWG fixture wire is _ amperes.

Meer zien Lees minder
Instelling
Residential Wireman Electrical
Vak
Residential Wireman Electrical









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Residential Wireman Electrical
Vak
Residential Wireman Electrical

Documentinformatie

Geüpload op
1 augustus 2023
Aantal pagina's
10
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LUCKYSTAR2022 West Virginia University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
904
Lid sinds
3 jaar
Aantal volgers
724
Documenten
9621
Laatst verkocht
2 dagen geleden
LUCKYSTAR2022

Hi there well come to luckystar2022. Here you will find guaranteed quality solution for Nursing and any other Accademic related notes, exams, study guides, cases and many more. 100% value for your time and money. GOOD LUCK

3.5

155 beoordelingen

5
62
4
25
3
25
2
8
1
35

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen