NICET Fire Alarm Level 1 Questions with 100% Correct Answers

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
28-07-2023
Written in
2022/2023

When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? <<Ans>> 18 months When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? <<Ans>> 66 inches Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the center-line of the door? <<Ans>> 21 feet At minimum, when working near power lines with voltage of 600 volts and lower, an aerial lift operator shall maintain which distance from the lines? <<Ans>> 10 feet The use of unprotected EMT shall be permitted under which conditions? <<Ans>> when in direct contact with the earth According to NFPA 70, what is the maximum unsupported length of 1/2-inch flexible metallic conduit where flexibility is required after installation? <<Ans>> 4 1/2 feet What is the maximum bend (in degrees) permitted in a conduit run between outlet boxes? <<Ans>> 360 Degrees If the primary power is disconnected and the fire alarm system goes into an alarm condition, what is the minimum acceptable time for secondary power to operate the voice evacuation systems? <<Ans>> 15 minutes A riser room temperature switch should activate when the temperature falls below which level? <<Ans>> 40 degrees F According to NFPA 72, what is the maximum sound pressure level permitted in a space with notification appliances? <<Ans>> 110 dBA What is the minimum interval for testing a single-station smoke detector in multifamily units? <<Ans>> Annually Where should a technician install a detector in relation to beam that is less than 12 inches deep and less that 8 feet in center? <<Ans>> At the bottom of the beam An existing fire alarm cable in a drop ceiling will be spliced. which one of the following splice locations will comply with NFPA 70? <<Ans>> secured inside a listed box or enclosure Which function shall be tested for each newly installed smoke detector? <<Ans>> smoke entry?

Show more Read less
Institution
NICET Fire Alarm Level 1
Module
NICET Fire Alarm Level 1









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NICET Fire Alarm Level 1
Module
NICET Fire Alarm Level 1

Document information

Uploaded on
July 28, 2023
Number of pages
7
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$7.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
gretzkyjohn5

Get to know the seller

Seller avatar
gretzkyjohn5 California University Of Pennsylvania
View profile
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
2 year
Number of followers
1
Documents
93
Last sold
1 year ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions