100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

TFM 12 Fire Alarm Technical Exam 2022 with complete solution

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
26-07-2023
Written in
2022/2023

TFM 12 Fire Alarm Technical Exam 2022 with complete solution Does a fire hood system and a kitchen need to be monitored by the fire alarm system? Yes What does P.L.F.A stand for? Power Limited Fire Alarm What does N.P.L.F.A stand for? Non-Power Limited Fire Alarm What is the difference between P.F.L.A and N.P.F.L.A? an N.P.L.F.A can operate at up to 600v, and the power output isn't limited a P.L.F.A has the voltage and power limited by a listed power source. What material must N.P.F.L.A circuit conductors be made from? ONLY solid stranded copper is permitted. What does A.W.G stand for? American Wire Gauge What size conductors are permitted? Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain capacities. What is used to protect transformers or other devices supplied from power-supply conductors? An over-current device not rated over 20 amperes. When located within 7 feet of the floor, how shall cables be fastened? Cables shall be fastened in an approved manner at intervals of not more than 18 inches. Single conductors shall not be smaller than ___ A.W.G? 18 Conductors of 28 A.W.G shall only be permitted in which circumstance? Spliced with a connector listed as suitable for 26 to 24 A.W.G How shall P.F.L.A conductors NOT be installed? P.F.L.A conductors shall not be strapped, taped, or attached to the exterior of any conduit or raceway. What is Plenum cable? Cable that can be installed in ducts, plenums, or other spaces used for environmental air. What is a Riser cable? Cable to be used in vertical wire runs in shafts between floors. Not to be used where Plenum cable is required. It is capable of preventing fire from rising from floor to floor. What is general purpose cable? Cable for general purpose fire alarm use. Not to be used where plenum cable or riser cable is required.

Show more Read less
Institution
Course









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Course

Document information

Uploaded on
July 26, 2023
Number of pages
7
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

TFM 12 Fire Alarm Technical Exam 2022 with complete
solution
Does a fire hood system and a kitchen need to be monitored by the fire alarm
system?
Yes
What does P.L.F.A stand for?
Power Limited Fire Alarm
What does N.P.L.F.A stand for?
Non-Power Limited Fire Alarm
What is the difference between P.F.L.A and N.P.F.L.A?
an N.P.L.F.A can operate at up to 600v, and the power output isn't limited

a P.L.F.A has the voltage and power limited by a listed power source.
What material must N.P.F.L.A circuit conductors be made from?
ONLY solid stranded copper is permitted.
What does A.W.G stand for?
American Wire Gauge
What size conductors are permitted?
Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain
capacities.
What is used to protect transformers or other devices supplied from power-
supply conductors?
An over-current device not rated over 20 amperes.
When located within 7 feet of the floor, how shall cables be fastened?
Cables shall be fastened in an approved manner at intervals of not more than 18
inches.
Single conductors shall not be smaller than ___ A.W.G?
18
Conductors of 28 A.W.G shall only be permitted in which circumstance?
Spliced with a connector listed as suitable for 26 to 24 A.W.G
How shall P.F.L.A conductors NOT be installed?
P.F.L.A conductors shall not be strapped, taped, or attached to the exterior of any
conduit or raceway.
What is Plenum cable?
Cable that can be installed in ducts, plenums, or other spaces used for environmental
air.
What is a Riser cable?
Cable to be used in vertical wire runs in shafts between floors. Not to be used where
Plenum cable is required.

It is capable of preventing fire from rising from floor to floor.
What is general purpose cable?
Cable for general purpose fire alarm use. Not to be used where plenum cable or riser
cable is required.

, It is resistant to the spread of fire.
Why 'type' shall plenum cable be? What substitutions are allowed?
Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be substituted.
Why 'type' shall riser cable be? What substitutions are allowed?
Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P.

C.M.R can be substituted.
What 'type' shall general purpose wire be? What substitutions are permitted?
Power Limited Fire Alarm (F.P.L) C.M.P, F.P.L.P, C.M.R, F.P.L.R, C.M.G

CM can be substituted (all types)
What is the maximum voltage permitted through multi-conductor N.P.F.L.A
cables?
150 volts
What is the voltage rating marked on P.F.L.A cables?
Not less than 300 volts
Shall the voltage rating marked on P.F.L.A cables?
No, because they may be mistakenly used for electrical applications.
What is 'Rate Compensation Detector'?
A device that responds when a temperature rises at an exceeding rate that is
predetermined.
What is a 'Smoke Detector'?
a device that detects both visible and invisible combustion particles?
Which detector is best a detecting invisible particles?
Ionization
Which sensor is better at detecting thick, visible smoke particles?
Photoelectric
What is a SPOT TYPE sensor?
a device in which detecting an element is concentrated at a particular location.
What is a DIGITAL ALARM COMMUNICATOR TRANSMITTER ( D.A.C.T)?
A system component at the protected premises is connected to the detection devices. It
has a line seizure and can connect to a D.A.C.R.
What is a DIGITAL ALARM COMMUNICATOR RECEIVER? (D.A.C.R)?
A system component that accepts and displays signals sent over the public phone
network from a D.A.C.T (i.e A.D.T monitoring center)
What is an alarm signal?
A signal indicating an emergency that requires immediate action.
What is a Supervisory signal?
A signal that indicates the need for action in connection with the SUPERVISION of fire
equipment.
What is a Trouble signal?
A signal that indicates a fault with the fire equipment. It must have an audible signal,
distinctive from alarm signals.
Does an exterior harm for a sprinkler system need to be supervised?
Yes

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICAIDSTORE Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
1196
Member since
4 year
Number of followers
889
Documents
11558
Last sold
1 week ago
ACADEMICAID STORE

Contact : Email: : I have solutions for : Nursing, Business, Economics, Accounting, statistics, chemistry, Biology and all Courses, Certifications and Subjects. Send us a message in case you need any additional information! Nursing Being my main profession line, I have essential guides that are Almost A+ graded, I am a very friendly person: If you would not agreed with my solutions I am ready for refund.

Read more Read less
4.1

173 reviews

5
95
4
29
3
28
2
6
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions