The preferred method for installing drip-edge flashing is _____________. - Answer- over the roofing paper/felt along the rake edge One of the main purposes of using crushed stone or gravel ballast on a built-up roof is to ________________. - Answer- protect the roof from sunlight A flat roof will usually have _____ installed. - Answer- internal drainage _____ flashing will be found along the peak of the roof. - Answer- ridge Slate tile roofs __________ be walked on. - Answer- should not Modern bathroom receptacles are typically on _________ circuits. - Answer- 20 amp GFCI ____________ should not be used as a grounding means. - Answer- water pipes Any GFCI breaker or receptacle that _____ should be written up as in need of immediate replacement. - Answer- fails to trip and reset properly Ohms Laws are mathematical models that allows inspectors to understand why a 30-amp fuse should not be connected to a 14-awg wire. T/F? - Answer- true The minimum cable size for a service entrance for a 200-amp supply is ______________. - Answer- 2/0 copper or 4/0 aluminum Wires to outlets are called __________. - Answer- branch circuit conductors AFCIs (arc fault circuit interrupters) are _____ to protect bedroom circuits. - Answer- protect _________ is defined as the flow of liquids in piping for a potable water distribution system in reverse of their intended path. - Answer- backflow T/F: The design of a drainage system is based on uniform flow in the drainage piping. - Answer- true __________ water heaters should not obtain combustion air from sleeping rooms, bathrooms or toilet rooms. - Answer- fuel-fired Glass doors enclosing the shower __________ made of safety glazing. - Answer- should be The standpipe and trap for an automatic clothes washer should be at least ____ inches in diameter. - Answer- 2 Vent pipes that pass through a roof should end ______ 6 inches above the roof. - Answer- at least In order to get good results in relation to observing water pressure at fixtures, it is good inspection procedural practice to inspect the plumbing fixtures at the ______ point in the dwelling. - Answer- highest Cleanouts for drainage pipes should be installed _____________ apart in horizontal drainage lines measured from the upstream entrance of the cleanout. - Answer- no more than 100 feet An automatic clothes washer must discharge its wastewater through a(n) _________ into a standpipe or laundry tub. - Answer- air gap or air break T/F: The purpose of the joist is to provide a nailing and support system for the floor sheathing and for the floor itself. - Answer- True Modifications to a bearing wall ______________. - Answer- generally need to be designed and approved by a licensed professional engineer A __________ is a space that is not a full basement and located between the ground and the bottom of the first floor of a home. - Answer- crawlspace The first course of horizontal lumber placed on top of and attached to the foundation wall is known as the _____________. - Answer- sill plate A _____ describes an assembly of three or four vertical studs nailed together to make up a corner framing element. - Answer- corner post Inspecting the _______ potentially poses one of the riskiest, unsafe parts of a home inspection. - Answer- crawlspace The ______ is installed at the intersection of roof rafters at their uppermost point. - Answer- ridge When an opening must be made in a load-bearing wall, a _______ must be placed horizontally to help support the load. - Answer- header While lifting a ladder, one should always _________. - Answer- lift with the leg muscles Doing tasks that require an awkward posture for more than one minute may contribute to ________. - Answer- a lower back injury Dog bites are _________ common than cat bites, but cat bites are more likely to become infected. - Answer- less A Type IA ladder supports a maximum of _______ pounds. - Answer- 300 T/F: Damaged ladders may still be used as long as they are properly labeled as to the extent of the damage identified. - Answer- False Methane gas, which may be present in confined spaces such as a basement, can cause death by __________. - Answer- asphyxiation

Show more Read less
Institution
Home Inspection
Course
Home Inspection










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Home Inspection
Course
Home Inspection

Document information

Uploaded on
June 22, 2023
Number of pages
24
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Home Inspection Exam Questions and Answers
The preferred method for installing drip-edge flashing is _____________. - Answer- over the roofing paper/felt along the rake edge
One of the main purposes of using crushed stone or gravel ballast on a built-up roof is to ________________. - Answer- protect the roof from sunlight
A flat roof will usually have _____ installed. - Answer- internal drainage
_____ flashing will be found along the peak of the roof. - Answer- ridge
Slate tile roofs __________ be walked on. - Answer- should not
Modern bathroom receptacles are typically on _________ circuits. - Answer- 20 amp GFCI
____________ should not be used as a grounding means. - Answer- water pipes
Any GFCI breaker or receptacle that _____ should be written up as in need of immediate replacement. - Answer- fails to trip and reset properly
Ohms Laws are mathematical models that allows inspectors to understand why a 30-
amp fuse should not be connected to a 14-awg wire. T/F? - Answer- true
The minimum cable size for a service entrance for a 200-amp supply is ______________. - Answer- 2/0 copper or 4/0 aluminum
Wires to outlets are called __________. - Answer- branch circuit conductors
AFCIs (arc fault circuit interrupters) are _____ to protect bedroom circuits. - Answer- protect
_________ is defined as the flow of liquids in piping for a potable water distribution system in reverse of their intended path. - Answer- backflow
T/F: The design of a drainage system is based on uniform flow in the drainage piping. - Answer- true
__________ water heaters should not obtain combustion air from sleeping rooms, bathrooms or toilet rooms. - Answer- fuel-fired Glass doors enclosing the shower __________ made of safety glazing. - Answer- should be
The standpipe and trap for an automatic clothes washer should be at least ____ inches in diameter. - Answer- 2
Vent pipes that pass through a roof should end ______ 6 inches above the roof. - Answer- at least
In order to get good results in relation to observing water pressure at fixtures, it is good inspection procedural practice to inspect the plumbing fixtures at the ______ point in the
dwelling. - Answer- highest
Cleanouts for drainage pipes should be installed _____________ apart in horizontal drainage lines measured from the upstream entrance of the cleanout. - Answer- no more than 100 feet
An automatic clothes washer must discharge its wastewater through a(n) _________ into a standpipe or laundry tub. - Answer- air gap or air break
T/F: The purpose of the joist is to provide a nailing and support system for the floor sheathing and for the floor itself. - Answer- True
Modifications to a bearing wall ______________. - Answer- generally need to be designed and approved by a licensed professional engineer
A __________ is a space that is not a full basement and located between the ground and the bottom of the first floor of a home. - Answer- crawlspace
The first course of horizontal lumber placed on top of and attached to the foundation wall is known as the _____________. - Answer- sill plate
A _____ describes an assembly of three or four vertical studs nailed together to make up a corner framing element. - Answer- corner post
Inspecting the _______ potentially poses one of the riskiest, unsafe parts of a home inspection. - Answer- crawlspace
The ______ is installed at the intersection of roof rafters at their uppermost point. - Answer- ridge
When an opening must be made in a load-bearing wall, a _______ must be placed horizontally to help support the load. - Answer- header
While lifting a ladder, one should always _________. - Answer- lift with the leg muscles Doing tasks that require an awkward posture for more than one minute may contribute to ________. - Answer- a lower back injury
Dog bites are _________ common than cat bites, but cat bites are more likely to become infected. - Answer- less
A Type IA ladder supports a maximum of _______ pounds. - Answer- 300
T/F: Damaged ladders may still be used as long as they are properly labeled as to the extent of the damage identified. - Answer- False
Methane gas, which may be present in confined spaces such as a basement, can cause
death by __________. - Answer- asphyxiation
Wooden and fiberglass ladders ________________ protect a person from electrical shock. - Answer- don't always
Many inspection-related back injuries can be attributed to __________________ lifting and ladder-climbing techniques. - Answer- poor
One-person inspection businesses _______________. - Answer- should be especially diligent with regard to safety because no one is looking out for the inspector but himself/herself
A minimum service of _____ amps is required for a single residential dwelling unit. - Answer- 100
Proper _________ of a building site is important for preventing wet basements, damp crawlspaces, erosion, and possible failure of the foundation. - Answer- drainage
All 15- and 20-amp 120-volt circuits for dining rooms, living rooms, bedrooms, sun rooms, closets, hallways, and similar areas in a home must be ______ -protected. - Answer- AFCI
If particleboard is used as wall sheathing, the grade mark with Type _____ or _____ should be stamped on it. - Answer- M1 or M2
In high-wind installations, if an old composition asphalt shingle roof is going to be replaced, the roofing contractor should ___________ the existing shingles and underlayment. - Answer- remove
Standpipes for clothes washers should extend at least ____ inches and no more than ____ inches above the trap weir. - Answer- at least 18" and no more than 42"

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Gordones22 Yala university
View profile
Follow You need to be logged in order to follow users or courses
Sold
492
Member since
3 year
Number of followers
351
Documents
9477
Last sold
1 month ago

4.1

107 reviews

5
63
4
16
3
13
2
4
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions