Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4,6 TrustPilot
logo-home
Examen

Oil Burner study guide with complete solutions

Note
-
Vendu
-
Pages
6
Grade
A+
Publié le
29-05-2023
Écrit en
2022/2023

What is a cad cell? - Answer- Visual flame detector What does "in-step" mean? - Answer- The primary control start circuit is closed What is the voltage found at the TT terminals? - Answer- 24 volts What are the 8 steps on a no heat call? - Answer- Main fuse, oil burner fuse, customer emergency switch, oil tank, oil valves, high limit, thermostat, primary control. How much air is necessary to burn a gallon of #2 fuel oil? - Answer- 1540 cubic ft What is the normal pump pressure? - Answer- 100 psi How is combustion achieved? - Answer- Proper amount of oil, air, and ignition What is primary air? - Answer- Air mixed with oil before the nozzle. It is the atomizing air found on in low pressure burners. What is secondary air? - Answer- Fan air Does firbebrick come in different heat ratings? - Answer- Yes How should an oil tank be supported? - Answer- Rigid, non-combustable supports What is the wire gauged used on oil burner circuits? - Answer- 14 gauge min How is an oil burner wired? - Answer- Series; intermittent or interrupted. What does intermittent mean? - Answer- The transformers stays on throughout the burner cycle What does interrupted mean? - Answer- The transformer drops out after flame is established. Who approves oil burners in MA? - Answer- Any approved national testing lab What does the term Marshall mean? - Answer- State Fire Marshall What size vent pipe is required with a 2 inch fill pipe? - Answer- 2" min Can a vent pipe on an oil tank be smaller than the fill? - Answer- No, it can be larger but not smaller What is the minimum size of vent and fill pipes? - Answer- 1 1/4" Explain interrupted ignition - Answer- Transformer drops out after the flame is established What permits are available? - Answer- Install, store oil, and tank removal What are the elements found in fuel oil? - Answer- 85% Carbon and 15% Hydrogen What is fuel oil? - Answer- Hydro-carbon How must fuel oil be prepared for combustion? - Answer- It is atomized or vaporized and mixed with air What is a BTU? - Answer- The amount of heat necessary to rain 1 lb of water 1 degree Fahrenheit How many BTU's are in a gallon of #2 fuel oil? - Answer- 140,000 What determines the GPH of a nozzle? - Answer- The orifice What is a series circuit? - Answer- the current has only one path to travel What is a degree day? - Answer- 65 degrees F minus the daily average temp What is the flash point of #2 fuel oil? - Answer- 110 degrees Fahrenheit Can materials other than steel be used for fuel oil tanks? - Answer- Yes, if approved What does the word "approved" mean? - Answer- Accepted b y the Marshall of by the laboratory which is accepted by the Marshall When is a combustion efficiency test required by law? - Answer- After installs and routine maintenances What control shorts off the oil burner in the event of excessive temp in the appliance - Answer- High limit Name 3 functions of an oil pump? - Answer- Pick-up, pressurize, and strain oil How is an oil burner wired - Answer- Intermittent or interrupted How is an oil burner circuit wired? - Answer- Series When does an oil line have to be sleeved? - Answer- When it is buried or in contact with earth or cement What is the exception to overhead fireproofing? - Answer- Any AFUE (annualized fuel utilization efficiency) rated appliance What does "in-step" mean? - Answer- The primary control start circuit is closed What is the minimum size oil lines for residential burners - Answer- 3/8" OD, 3/8" IPS Is a permit required for the removal of an oil tank? - Answer- Yes Cross connections between two supply tanks shall not exceed ____________ gallons total. - Answer- 660 How is safety timing checked on a stack switch? - Answer- Remove the switch from its holder or disconnect terminal three, fire unit, and time its lockout. What is safety lockout timing firing under 3 GPHV ? - Answer- 15 seconds maximum. Is a combustion test required for tank replacement? - Answer- No Where should a thermal valve be installed on a supply line from the tank? - Answer- Connected at the bottom of the supply tank. What is a cadmium sulfide cell? - Answer- A resistor which changes its characteristics of conductivity in a direct proportion to the light striking it. What is the minimum size pipe that can be used for residential oil lines, and can right and left couplings be used? - Answer- 3/8" OD and 3/8" IPS minimum and right and left couplings are forbidden. What safety devices are found on a rotary burner? - Answer- A constant level valve and a solenoid valve. How is the oil flow regulated on a rotary burner? - Answer- The constant level valve When is a vent alarm used? - Answer- When gauge is not visible from fill When is a vent pipe required - Answer- All tanks that are larger than 10 gallons What must be done after an installation has been completed? - Answer- Submit a certificate of completion. When should your oil burner install certificate of completion be submitted? - Answer- Local fire department What is the time limit for submitting certificates of completion? - Answer- 72 hrs, excluding Saturday, Sunday, and all holidays. What is a confined space? - Answer- Less than 50 cu. ft. per 1,000 BTU's What is a gallon? - Answer- 231 cu. in. at a temp of 60 degrees Fahrenheit What are the element in air? - Answer- Nitrogen 80% or 79% Oxygen 20% or 21% How much air is required to burn a gallon of #2 fuel oil and why? - Answer- 1540 cu. ft.; This is the most amount of air needed to burn all the oil most efficiently. What kind of counts are used on oil tank installs? - Answer- Swing joints What are swing joints used on oil tanks? - Answer- To allow for movement or settlings without pipe or tank damage, and to enable piping to pitch back to tanks. What is the minimum distance that a burner must be from a tank? - Answer- 5' How many gallons of oil may be stored without a permit? - Answer- 10 gallons How much outside or replacement air is needed in a confined space - Answer- 140 sq." top and bottom per gallon per hour 1 sq." per 1000 BTU's How much outside or replacement air is needed in a boiler room of tight construction? - Answer- 28 sq." per gallon per hour 1 sq." per 5,000 BTU's What is a flame detector? - Answer- A device that sense flame thermally or visually What is a cad cell? - Answer- A visual flame sensor What is a purpose of a heat anticipator? - Answer- Prevents overheating Explain the differentials in a thermostat. - Answer- Mechanical - the operation of the helix; turns the appliance on and off Electrical - operation of the anticipator; prevents overheating What are the parts of an ignition assembly? - Answer- High voltage transformer, buss bars or high tension leads, insulators, and electrodes.

Montrer plus Lire moins
Établissement
Oil Burner
Cours
Oil Burner









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Oil Burner
Cours
Oil Burner

Infos sur le Document

Publié le
29 mai 2023
Nombre de pages
6
Écrit en
2022/2023
Type
Examen
Contient
Questions et réponses

Sujets

  • how much air i

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Gordones22 Yala university
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
498
Membre depuis
3 année
Nombre de followers
351
Documents
9500
Dernière vente
1 semaine de cela

4.1

108 revues

5
63
4
17
3
13
2
4
1
11

Documents populaires

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions