NFPA-99: Practice Test Questions and Answers complete Under which of these conditions shall the instrument Air Reserve header cylinders be permitted to be stored with the instrument air compressor? A) the mechanical equipment room does not contain a boiler. B) the medical air compressors are in the same room. C) the only motor-driven machinery in the room is for instrument air equipment. D) the room is secured with lockable doors. C) The only motor-driven machinery in the room is for the instrument air equipment Riser valves are those valves located where? A) adjacent to the main riser downstream of any zone valve. B) anywhere in the lateral branches of the piping system. C) in the mainline adjacent to the base of the riser. D) in the riser adjacent to the mainline. D) In the riser adjacent to the main line When is the initial pressure test conducted by the installer? A) after blowdown of the distribution piping. B) after installation of alarm sensors. C) before blowdown of distribution piping. D) before installation of station rough in assembly. A) After blow-down of the distribution piping. In those portions of systems intended to handle oxygen at pressure greater than 350 psi the inter connecting hose shall not contain what materials? A) brass. B) copper C) polymeric D) stainless steel C) Polymeric The tool shown here allows the installer to mechanically limit the makeup depth of the fitting to be brazed. Under what condition is this method permitted for the installation of medical gas piping? A) only on final line connectors. B) only on vacuum systems. C) where only B cup 5 brazing rod is used D) where the limited makeup depth is not less than minimum cut depth her ANSI / ASME recommendations D) Where the limited makeup depth is not less than minimum cup depth current ANSIASME recommendation What is the standard gauge pressure for nitrogen gas service? A) 15 - 30 B) 50 - 55 C) 162 185 D) it varies with system type. C) 50 - 55 psi

Show more Read less
Institution
Module









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Module

Document information

Uploaded on
May 2, 2023
Number of pages
15
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NFPA-99: Practice Test Questions and Answers 2022-2023
complete
Under which of these conditions shall the instrument Air Reserve header cylinders be
permitted to be stored with the instrument air compressor?
A) the mechanical equipment room does not contain a boiler.
B) the medical air compressors are in the same room.
C) the only motor-driven machinery in the room is for instrument air equipment.
D) the room is secured with lockable doors.
C) The only motor-driven machinery in the room is for the instrument air equipment
Riser valves are those valves located where?
A) adjacent to the main riser downstream of any zone valve.
B) anywhere in the lateral branches of the piping system.
C) in the mainline adjacent to the base of the riser.
D) in the riser adjacent to the mainline.
D) In the riser adjacent to the main line
When is the initial pressure test conducted by the installer?
A) after blowdown of the distribution piping.
B) after installation of alarm sensors.
C) before blowdown of distribution piping.
D) before installation of station rough in assembly.
A) After blow-down of the distribution piping.
In those portions of systems intended to handle oxygen at pressure greater than 350 psi
the inter connecting hose shall not contain what materials?
A) brass.
B) copper
C) polymeric
D) stainless steel
C) Polymeric
The tool shown here allows the installer to mechanically limit the makeup depth of the
fitting to be brazed. Under what condition is this method permitted for the installation of
medical gas piping?
A) only on final line connectors.
B) only on vacuum systems.
C) where only B cup 5 brazing rod is used
D) where the limited makeup depth is not less than minimum cut depth her ANSI /
ASME recommendations
D) Where the limited makeup depth is not less than minimum cup depth current ANSI\
ASME recommendation
What is the standard gauge pressure for nitrogen gas service?
A) 15 - 30
B) 50 - 55
C) 162 185
D) it varies with system type.
C) 50 - 55 psi

, What is a NFPA 99 requirement for labeling of pipes in medical gas system?
A) color coding
B) fixed label with
C) label shall wrap completely around pipe.
D) reflective label
A) Color coding
A wireless communication device is employed in a medical gas or vacuum warning
system. what type of supervision is required for this device?
A) a visual indicator Shelby located in maintenance officer or engineering department.
B) this device shall be installed at the medical gas or vacuum source.
C) this device shall be located at nurses station.
D) this device will be supervised such that failure communication shall initiate an alarm.
D) This device will be supervised such that failure of communication shall initate an
alarm
In a facility where Medical Gas vacuum systems are present and the failure of such
equipment or systems is likely to cause any major injury or death to patients or
caregivers this system shall be designed to meet which category requirements?
A) 1
B) 2
C) 3
D) 4
A) category 1
A faculty is in the planning stages of installing an emergency oxygen service connection
(ESOC). How many feet is the minimum amount of clearance required around this
connection?
A) 1 foot
B) 3 feet
C) 5 feet
D) Clearance must be 1-1/2 times the width of the auxiliary.
B) 3 feet
Wooden rack for cylinder storage may be permitted under which conditions?
A) the wooden must be painted.
B) they are permitted with no set conditions .
C) they must be located in an area with fire suppression system.
D) Wooden racks are no longer permitted
D) Wooden racks are no longer permitted
If nonmetallic flexible connectors is being used in a category 1 healthcare faculty to
connect to the manifold to the gas distribution piping what is the maximum length
permitted for the flexible connectors?
A) 2.5 feet
B) 5 feet
C) They shall be no longer necessary
D) the use of flexible connectors is not permitted.
C) They shall be no longer necessary
What type of copper tube hanger shall be used for potentially damp locations?
A) carbon steel

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LECTMAGGY Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
145
Member since
3 year
Number of followers
121
Documents
6310
Last sold
3 months ago
LECTMAGGY

Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.2

27 reviews

5
7
4
3
3
11
2
0
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions