100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Textbook of Diagnostic Sonography 8th Edition Hagen-Ansert Test Bank Chapter 1 - 65 Updated Guide 2022

Beoordeling
1.0
(1)
Verkocht
3
Pagina's
466
Cijfer
A+
Geüpload op
23-10-2022
Geschreven in
2022/2023

Textbook of Diagnostic Sonography 8th Edition Hagen-Ansert Test Bank Textbook of Diagnostic Sonography 8th Edition Hagen-Ansert Test Bank Chapter 1 - 65 Updated Guide 2022

Instelling
Sonography
Vak
Sonography











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Sonography
Vak
Sonography

Documentinformatie

Geüpload op
23 oktober 2022
Aantal pagina's
466
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Textbook of Diagnostic Sonography 8th Edition Hagen -Ansert Test Bank Chapter 01: Foundations of Clinical Sonography Hagen -Ansert: Textbook of Diagnostic Sonography, 8th Edition MULTIPLE CHOICE 1. Historically, the development of ultrasound began shortly after: a. radio communication in World War I. b. sonar in World War II. c. nuclear testing in World War II. d. the launching of Sputnik. ANS: B World War II brought sonar equipment to the forefront for defense purposes. Ultrasound was influenced by the success of sonar equipment. PTS: 1 REF: p. 7 OBJ: Detail a timeline for pioneers in the advancement of medical diagnostic ultrasound. TOP: Historical overview of sound theory and medical ultrasound 2. The early applications of obstetric ultrasound were initiated by: a. Joseph Holmes. b. Ian Donald. c. John Howry. d. William Fry. ANS: B The early obstetric compound scanner was built by Tom Brown and Dr. Ian Donald in Scotland in 1957. PTS: 1 REF: p. 7 OBJ: Detail a timeline for pioneers in the advancement of medical diagnostic ultrasound. TOP: Historical overview of sound theory and medical ultrasound 3. Visualization of the cardiac structures in the heart was discovered by: a. Joseph Holmes. b. Ian Donald. c. Hertz and Edler. d. George Ludwig. ANS: C In 1954, echocardiographic techniques were developed in Sweden by Drs. C.H. Hertz and I. Edler. PTS: 1 REF: p. 7 OBJ: Detail a timeline for pioneers in the advancement of medical diagnostic ultrasound. TOP: Historical overview of sound theory and medical ultrasound 4. Which one of the following statements about the role of sonographers is false ? a. Sonographers perform ultrasound studies and gather diagnostic data independent of the physician. b. Sonographers must possess intellectual curiosity and perseverance. c. Sonographers must have a technical aptitude. d. Sonographers must be able to communicate on different levels. ANS: A A sonographer performs ultrasound studies gathering diagnostic data under both the direct and the indirect supervision of a physician. They also must assess clinical history and symptoms, interpret laboratory values, and understand other diagnostic examina tions. PTS: 1 REF: p. 5 OBJ: Describe a career in ultrasound. TOP: Role of the sonographer 5. In soft tissues, the assumed propagation velocity is (in meters per second) : a. 1320. b. 1450. c. 1540. d. 1650. ANS: C In soft tissues, the assumed propagation velocity (speed) is 1540 meters per second. PTS: 1 REF: p. 9 OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound. TOP: Introduction to basic ultrasound principles - Acoustics 6. Diagnost ic ultr asound usesNtheRfreqIuenGciesBo.f:C M a. 10 to 15 kHz. b. 1 to 20 kHz. c. 100 to 1000 Hz. d. 1 to 20 MHz. ANS: D Diagnostic application of ultrasound uses frequencies of 1 to 20 million cycles per second (1 to 20 MHz). PTS: 1 REF: p. 9 OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound. TOP: Introduction to basic ultrasound principles - Acoustics 7. The device that converts energy from one form to another is called the: a. digitizer. b. transducer. c. scan converter. d. beam former. ANS: B Piezoelectric elements (transducers) convert electric energy into ultrasound energy and vice versa. PTS: 1 REF: p. 12 OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound. TOP: Introduction to basic ultrasound principles - Acoustics 8. The angle of reflection is equal to the: a. acoustic impedance. b. angle of incidence. c. refraction. d. image resolution. ANS: B Angle of reflection is the angle between the reflected sound direction and a line perpendicular to the media boundary. PTS: 1 REF: p. 6 OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound. TOP: Historical overview of sound theory and medical ultrasound 9. The display mode that shows time along the horizontal axis and depth along the vertical axis is: a. A mode. b. B mode. c. M-mode. d. real-time. ANS: C Motion mode (M-mode) displays the depth along the vertical axis versus the time along the horizontal axis. PTS: 1 REF: p. 15 OBJ: Identify ultrasound instruments and discuss their uses. TOP: Pulse -echo display modes - M-mode 10. Which one of the following statements about the Doppler principle is false ? a. Doppler refers to a change in frequency in which the motion of laminar or turbulent flow is detected within a vascular structure. b. The beam should be perpendicular to the flow. c. The Doppler shift is directly proportional to the velocity of the red blood cell. d. If the red blood cell moves away from the transducer, then the fall in frequency is directly proportional to the velocity and direction of the red blood cell movement. ANS: B The beam should be parallel to the flow to obtain the maximum velocity. The frequency of the Doppler shift is proportional to the cosine of the Doppler angle. At a 90 -degree angle (perpendicular to flow), the Doppler shift is zero, regardless of the flow velocity. PTS: 1 REF: p. 18 |p. 19 OBJ: Discuss three -dimensional and Doppler ultrasound. TOP: Doppler Ultrasound - Doppler Shift 11. The Fresnel zone is also called the: a. far field. b. focal point. c. near zone. d. Nyquist limit. ANS: C The Fresnel or near zone is the field closest to the transducer during the formation of the sound beam. PTS: 1 REF: p. 18 OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound. TOP: System Controls for Image Optimization - Focal Zone 12. The higher the transducer frequency, the: a. shorter the wavelength. b. faster the frame rate. c. deeper the penetration depth. d. slower the frame rate. ANS: A The higher the frequency, the shorter the wavelength (inversely related). PTS: 1 REF: p. 18 | p. 22 OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound. TOP: Introduction to basic ultrasound principles - Image resolution

Beoordelingen van geverifieerde kopers

Alle reviews worden weergegeven
1 jaar geleden

1.0

1 beoordelingen

5
0
4
0
3
0
2
0
1
1
Betrouwbare reviews op Stuvia

Alle beoordelingen zijn geschreven door echte Stuvia-gebruikers na geverifieerde aankopen.

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NurseGrades Chamberlain College Nursing
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
7668
Lid sinds
4 jaar
Aantal volgers
5612
Documenten
1984
Laatst verkocht
3 dagen geleden
Nursing school is hard! Im here to simplify the information and make it easier!

My mission is to be your LIGHT in the dark. If you're worried or having trouble in nursing school, I really want my notes to be your guide! I know they have helped countless others get through and that's all I want for YOU! Stay with me and you will find everything you need to study and pass any tests, quizzes and exams!

4.1

860 beoordelingen

5
474
4
158
3
111
2
31
1
86

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen