CBSPD Exam / CBSPD Sterile Processing Technician Certification Exam (CSPDT) all correctly answered.

Rating
-
Sold
-
Pages
30
Grade
A+
Uploaded on
18-06-2022
Written in
2021/2022

CBSPD Exam / CBSPD Sterile Processing Technician Certification Exam (CSPDT) all correctly answered.

Institution
CBSPD Sterile Processing Technician
Course
CBSPD Sterile Processing Technician










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
CBSPD Sterile Processing Technician
Course
CBSPD Sterile Processing Technician

Document information

Uploaded on
June 18, 2022
Number of pages
30
Written in
2021/2022
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • cbspd
  • cbspd exam
  • cbspd exam 2022

Content preview

CBSPD Exam 2022 / CBSPD Sterile Processing Technician Certification
Exam (CSPDT) all correctly answered.



Superheating can occur - answerIf the steam pressure is too low for the set temperature



Wet packs - answerWet steam can cause



68-73 degrees - answerAAMI recommends that the temperature in the sterilization area be:



30%-60% - answerAAMI recommends that the humidity is the sterilization area be



10 - answerThe recommended ventilation in the sterilization are is—— air exchanges per hour under
positive pressure



75-85/10/negative - answerAAMI recommends that the temperature in the sterilizer access area be
—- with — air exchanges per hour and under — pressure



Decon, the sterilizer access area, EVS closet - answerThe only 3 areas in SPD that should have negative
pressure are:



sterility - answer— is the absence of all forms of microbial life, including bacterial spores



One in a million; 10(-6) - answerAn item is considered sterile if there is less than —— chance that a
viable microorganism has survived the sterilization process. This is reflected numerically as —-



Sterility Assurance Level - answerSAL=

,Steam - answer— kills microorganisms by denature great the protein



steam sterilization - answer— is the most common form of sterilization for items that are heat- and
moisture-tolerant



saturated steam under pressure, time, and temperature - answerThree parameters of steam
sterilization cycles are



Dynamic-air-removal cycles - answer— are used in prevacuum sterilized and in steam-flush
pressure-pulse (SFPP)



Prevacuum sterilizers - answer— remove air by drawing series of vacuums with an injection of steam
between each vacuum pull.



Bowie-Dick test - answerPerformed daily to detect air leaks or inadequate air removal from
prevacuum sterilzers



Gravity-displacement cycles - answerIncoming steam displaces residual air through the drain at the
bottom of the sterilizer chamber:



Gravity-displacement - answerBecause there is no mechanical air removal in a —, a Bowie-Dick test is
not required for — or sterilizers



Boiler - answerIn most healthcare facilities, steam is generated inside of a:



60-80psig - answerThe required pressure of steam as it enters the jacket is usually:



28-30 lbs of pressure - answerFor a sterilizer operating at 270 degrees, the sterilizer gauge will show:



An insulating jacket - answerProvides heat inside the chamber to prevent condensation from forming

, on the chamber walls:



Heat-sensing thermometer - answerThe sterilizers - - - is locates in the drain line



The drain line - answerThe coldest part of sterilizer is



Bottom rack, drain line - answerAll PCDs should be placed on the —, directly over the —



On the bottom rack above the drain line - answerThe Bowie-Dick test pack is placed



Conditioning, sterilization/exposure/"holding, Exhaust, Drying - answerThe phases of steam
sterilization cycles are:



Conditioning phase - answerDuring this phase, air is removed from the sterilization chamber and
steam is injected



Sterilization/exposure/holding - answerIn this phase, the exposure temperature is maintained for the
prescribed amount of time.



Exhausted, Exhaust phase - answerAfter the exposure phase, steam is — from the sterilizer through the
chamber drain line is this phase:



Drying phase - answerAfter the steam has been exhausted, the sterilizer goes into the - of the cycle
which typically lasts about 30 minutes



• 4 minutes @ 270 and 28-30 psi

• 3 minutes @ 275 and 38-30 psi - answerThe cycle for wrapped items using Dynamic-air-removal
steam is:

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
luzlinkuz Chamberlain University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1428
Member since
4 year
Number of followers
849
Documents
27650
Last sold
1 day ago

3.7

303 reviews

5
131
4
61
3
54
2
17
1
40

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions