This document contains 425 practice questions and answers covering pacemaker and ICD technology, pacing systems, lead function and failure, device circuitry, electrophysiology, arrhythmia management, battery chemistry, sensing, pacing thresholds, and device troubleshooting. It includes detailed multiple-choice questions with indicated answers across topics relevant to IBHRE examination preparation.

Content preview

IBHRE EXAM NEWEST 2026/2027 ACTUAL EXAM COMPLETE 425
QUESTIONS WITH DETAILED VERIFIED ANSWERS (100%




A function of pacemaker circuitry that allows the pacemaker output pulse to be dissipated quickly
maximizing both the output and sensing capabilities.



a) circuit resistors

b) charge dump

c) pulse neutralizer

d) current consumption - Correct answer-B. Charge Dump



AV sequentially paced patients with frequent ventricular ectopy should have the following pacemaker
parameters programmed to decrease the chance of competition:



a) short blanking period

b) slower base rate

c) increased ventricular refractory period

d) none of the above - Correct answer-A. Short Blanking Period



Low threshold electrode materials include each of the following EXCEPT:



a) iridium oxide

b) elgiloy

c) platinized platinum

d) titanium nitride - Correct answer-B. Elgiloy

,The strength duration curve resulting in a parabolic shape is described by which of the following
formulas?



a) I x t

b) I x V x t

c) I x R

d) all of the above - Correct answer-B. I x V x t



The ventriculoatrial conduction time of a pacemaker patient with a typical endless-loop-tachycardia may
be calculated by which equation?



a) (upper rate limit interval) - ( AV delay + PVARP)

b) (upper rate limit interval) - ( AV delay + PVARP + Wenckebach interval

c) (lower rate limit interval) - ( upper rate limit interval)

d) none of the above - Correct answer-D. None of the above



Which of the following programmings would not prevent crosstalk?



a) a prolonged blanking period

b) "safety pacing"

c) low atrial output

d) less sensitive ventricular sensitivity - Correct answer-B. "Safety Pacing"



The most commonly used battery chemistry in ICDs is:



a) lithium thionyl chloride

b) lithium manganese dioxide

,c) lithium silver vanadium oxide

d) lithium manganese dioxide - Correct answer-C. Lithium Silver Vanadium Oxide



The purpose of a capacitor in an electrical circuit is to:



a) convert AC to DC current

b) store electrical charge

c) rapidly switch battery voltage on or off

d) limit current flow to a single direction - Correct answer-B. Store Electrical Charge



A programming mode that would NOT be utilized to manage intermittent atrial fibrillation in a patient
with a DDD pacemaker is:.



a) DDI

b) DVI

c) VDD

d) VVI - Correct answer-C. VDD



Variations in stimulus morphology on the surface ECG of an analog recorder may be caused by:



a) a dislodged electrode

b) an electrical short

c) changes in patient position

d) all of the above - Correct answer-D. All of the above



All of the following have been used as ERI magnet responses except:



a) abrupt increase in rate

, b) abrupt decrease in rate

c) gradual increase in rate

d) gradual decrease in rate - Correct answer-C. Gradual Increase In Rate



Which of the following has not been used as an indicator of battery depletion?



a) pulse width stretching

b) mode change

c) programmed amplitude reversion

d) telemetered battery impedance - Correct answer-C. Programmed Amplitude Reversion



The electrical circuit that converts a signal with both positive and negative components into a signal with
only one component?



a) resistor

b) rectifier

c) diode

d) capacitor - Correct answer-B. Rectifier



Which of the following would account for the most common cause of inappropriate mode switching?



a) ventricular lead sensing atrial signals

b) lead insulation break

c) oversensing EMI

d) atrial lead sensing ventricular signals - Correct answer-D. Atrial Lead Sensing Ventricular Signals



A patient's stimulation threshold was 1.0 Volt & 0.4 msec pulse duration. The pacemaker is programmed
to 2.0 Volt & 0.8 msec duration. Lead impedance measures 1000 Ohms. The output energy for this
patient would be:

Document information

Uploaded on
August 13, 2026
Number of pages
120
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Studyvaultpro
1.0
(1)
Sold
9
Followers
0
Items
477
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions