Power Systems Engineer Licensing Exam
Practice Questions And Correct Answers
(Verified Answers) Plus Rationale 2026
Q&A| Instant Download Pdf


1. A three-phase power system has a balanced load connected in a star
configuration. If the line voltage is 400 V, what is the phase voltage across
each load impedance?

A. 400 V
B. 346 V
C. 231 V
D. 200 V

B. 346 V

In a balanced star-connected system, the phase voltage is equal to the line
voltage divided by √3. Therefore, 400/√3 ≈ 231 V, making option C correct.

2. In a power system, the main purpose of a circuit breaker is to:

,A. Increase system voltage stability
B. Interrupt fault currents safely
C. Reduce transmission losses
D. Improve generator efficiency

B. Interrupt fault currents safely

Circuit breakers are protective switching devices designed to interrupt
abnormal currents such as short circuits while allowing normal system
operation.

3. The per-unit system in power engineering is mainly used because it:

A. Eliminates the need for transformers
B. Simplifies calculations across different voltage levels
C. Increases generator output power
D. Removes the need for protective relays

B. Simplifies calculations across different voltage levels

The per-unit system normalizes electrical quantities, making calculations
involving different voltage levels and equipment ratings easier and less
error-prone.

4. A synchronous generator operates at 50 Hz and has 20 poles. What is
its synchronous speed?

,A. 150 rpm
B. 300 rpm
C. 600 rpm
D. 1500 rpm

C. 300 rpm

The synchronous speed is calculated using Ns = 120f/P. For 50 Hz and 20
poles, Ns = (120 × 50)/20 = 300 rpm.

5. The primary function of a power transformer in a transmission system
is to:

A. Convert AC power into DC power
B. Increase or decrease voltage levels
C. Generate electrical energy
D. Store electrical energy

B. Increase or decrease voltage levels

Power transformers transfer electrical energy between circuits while
changing voltage levels to allow efficient transmission and distribution.

6. Ferranti effect in transmission lines occurs when:

A. Current increases during faults
B. Receiving-end voltage exceeds sending-end voltage under light load

, C. Frequency decreases during overload
D. Transformer losses increase

B. Receiving-end voltage exceeds sending-end voltage under light load

The Ferranti effect results from line capacitance causing voltage rise at the
receiving end of long transmission lines operating with little or no load.

7. The main purpose of power factor correction is to:

A. Increase reactive power consumption
B. Reduce system efficiency
C. Improve voltage regulation and reduce losses
D. Increase transmission frequency

C. Improve voltage regulation and reduce losses

Power factor correction reduces unnecessary reactive current, improving
efficiency, reducing losses, and improving voltage performance.

8. A lagging power factor in an industrial load is commonly caused by:

A. Capacitor banks
B. Inductive motors
C. Resistive heaters
D. Batteries

B. Inductive motors

Document information

Uploaded on
August 11, 2026
Number of pages
45
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$24.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Guestt
4.4
(5)
Sold
11
Followers
0
Items
2091
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions