A. 4 feet 7 inches and 12 sixtieths
BCSI 2013/2015 Edition pg 11 - (Answer)A dimension string of 4-7-12 when setting trusses
means.
A. 4 feet 7 inches and 12 sixtieths
B. 4 feet 7 inches and 12 eighths
C. 4 feet 7 inches plus or minus 3/4''
D. 4 to 7 feet plus 12 inches
D. 2.00
Walkers Builders Est ref book pg 1047/770 - (Answer)The R value of an 8-inch light weight
aggregate block is?
A. .44
B. .64
C. 1.11
D. 2.00
,B. Department of Health and Rehabilitative Services
Contractors Manual, 2017 pg 2-13 - (Answer)The agency responsible for issuing a permit for an
abandoned septic tank is the?
A. Department of Business and Professional Regulation
B. Department of Health and Rehabilitative Services
C. Environmental Protection Agency
D. Florida Department of Environmental Protection
D. The alteration shall comply with the requirements to the maximum extent feasible
Fl Builders code 2014/2017, Accessibility pg 202.3 - (Answer)During the bathroom alteration it
was determined it was technically infeasible to construct a standard stall. Which of the following
is a reasonable option?
A. Install a variety of water closets
B. Install a unisex bathroom
C. The contractor shall apply for an accessible variance within 90 days
D. The alteration shall comply with the requirements to the maximum extent feasible
D. NFPA 13
, Fl Builders code 2014/2017, Residential pg R302.3 - (Answer)A fire-resistance rating of 1/2
hour shall be permitted in buildings equipped throughout with an automatic sprinkler system
installed in accordance with?
A. OSHA 1926
B.AZSI 119.62(a)
C. ASTM E 119 of UL 263
D. NFPA 13
D. 1/2 Inch
OSHA 29 CFR 1926 pg .705(g) - (Answer)During lifting, all points at which the slab is
supported shall be kept within _________ of that needed to maintain the slab in a level position.
A. 1/2 foot
B. 1/4 inch
C. 3/4 foot
D. 1/2 inch
A. 3/16 to 3/8
Principles & Practices of commercial construction pg 27 - (Answer)The diameter of a red
construction laser light is normally ______inch(es)
QUESTIONS WITH EXPERT SOLUTION | 2026 LATEST UPDATED GET
A+
A. 4 feet 7 inches and 12 sixtieths
BCSI 2013/2015 Edition pg 11 - (Answer)A dimension string of 4-7-12 when setting trusses
means.
A. 4 feet 7 inches and 12 sixtieths
B. 4 feet 7 inches and 12 eighths
C. 4 feet 7 inches plus or minus 3/4''
D. 4 to 7 feet plus 12 inches
D. 2.00
Walkers Builders Est ref book pg 1047/770 - (Answer)The R value of an 8-inch light weight
aggregate block is?
A. .44
B. .64
C. 1.11
D. 2.00
,B. Department of Health and Rehabilitative Services
Contractors Manual, 2017 pg 2-13 - (Answer)The agency responsible for issuing a permit for an
abandoned septic tank is the?
A. Department of Business and Professional Regulation
B. Department of Health and Rehabilitative Services
C. Environmental Protection Agency
D. Florida Department of Environmental Protection
D. The alteration shall comply with the requirements to the maximum extent feasible
Fl Builders code 2014/2017, Accessibility pg 202.3 - (Answer)During the bathroom alteration it
was determined it was technically infeasible to construct a standard stall. Which of the following
is a reasonable option?
A. Install a variety of water closets
B. Install a unisex bathroom
C. The contractor shall apply for an accessible variance within 90 days
D. The alteration shall comply with the requirements to the maximum extent feasible
D. NFPA 13
, Fl Builders code 2014/2017, Residential pg R302.3 - (Answer)A fire-resistance rating of 1/2
hour shall be permitted in buildings equipped throughout with an automatic sprinkler system
installed in accordance with?
A. OSHA 1926
B.AZSI 119.62(a)
C. ASTM E 119 of UL 263
D. NFPA 13
D. 1/2 Inch
OSHA 29 CFR 1926 pg .705(g) - (Answer)During lifting, all points at which the slab is
supported shall be kept within _________ of that needed to maintain the slab in a level position.
A. 1/2 foot
B. 1/4 inch
C. 3/4 foot
D. 1/2 inch
A. 3/16 to 3/8
Principles & Practices of commercial construction pg 27 - (Answer)The diameter of a red
construction laser light is normally ______inch(es)