Forced air furnace with an open draft hood and open burners is considered..... ✔Correct
Answer-Low efficiency
A fan downstream from the heat exchanger is intended to ✔Correct Answer-Push the
combustion gases through the heat exchanger
Low efficiency furnace could be located in the..... ✔Correct Answer-Garage
Te max distance from the attic access to an attic furnace is... ✔Correct Answer-20 feet
A furnace in an interior closet can have it's lower and upper combustion air sources vented to
the..... ✔Correct Answer-Attic
Minimum clearance of a "B" vent to a combustible material is... ✔Correct Answer-Defendant
on the manufacturers instructions
Minimum height for a "B" vent penetrating the roof is ✔Correct Answer-12 inches above the
roof
A "B" vent termination must be at least 2 feet higher than any wall within... ✔Correct Answer-
8 feet
The Venturi on a gas burner controls the.... ✔Correct Answer-Gas to air mixture
All gas forced air furnaces must have a safety device that shuts off the gas in the event the pilot
goes out called a..... ✔Correct Answer-Thermocouple
Every forced air furnace must have an electrical disconnect.... ✔Correct Answer-Within sight
of the furnace
Oil burning appliance vents are usually vented with what type of pipe? ✔Correct Answer-Type
"L"
Typical minimum temp on a hydronic heating system is..... ✔Correct Answer-160 degrees
Sight glass is not found in hydronic heating systems, but is found in what other type?
✔Correct Answer-Steam
Verified Answers |Guaranteed to Pass
Forced air furnace with an open draft hood and open burners is considered..... ✔Correct
Answer-Low efficiency
A fan downstream from the heat exchanger is intended to ✔Correct Answer-Push the
combustion gases through the heat exchanger
Low efficiency furnace could be located in the..... ✔Correct Answer-Garage
Te max distance from the attic access to an attic furnace is... ✔Correct Answer-20 feet
A furnace in an interior closet can have it's lower and upper combustion air sources vented to
the..... ✔Correct Answer-Attic
Minimum clearance of a "B" vent to a combustible material is... ✔Correct Answer-Defendant
on the manufacturers instructions
Minimum height for a "B" vent penetrating the roof is ✔Correct Answer-12 inches above the
roof
A "B" vent termination must be at least 2 feet higher than any wall within... ✔Correct Answer-
8 feet
The Venturi on a gas burner controls the.... ✔Correct Answer-Gas to air mixture
All gas forced air furnaces must have a safety device that shuts off the gas in the event the pilot
goes out called a..... ✔Correct Answer-Thermocouple
Every forced air furnace must have an electrical disconnect.... ✔Correct Answer-Within sight
of the furnace
Oil burning appliance vents are usually vented with what type of pipe? ✔Correct Answer-Type
"L"
Typical minimum temp on a hydronic heating system is..... ✔Correct Answer-160 degrees
Sight glass is not found in hydronic heating systems, but is found in what other type?
✔Correct Answer-Steam