COMPLETE QUESTIONS AND ANSWERS

◉ 800 CCA or 100 Ahr (exceptions: electronic equipment with
battery backed memories; safety equipment such as bilge pumps,
alarms, CO detectors, bilge blowers; battery chargers; I'm pressed
current systems..
Answer: Per ABYC E-10, a battery switch must be installed in the
positive conductor from each battery bank with a CCA rating greater
than ____ (or greater than _____ Ah if CCA rating not available).


◉ AIC = 5000 Amps (E-11 table IV-A).
Answer: What is the minimum ampere interrupting capacity (AIC)
for main overcurrent protection on a battery bank rated at 12 V,
1500 CCA?


◉ AIC = 2X mnfg's short-circuit rating or 100X nominal Ahr rating..
Answer: What is the minimum ampere interrupting capacity (AIC)
for main overcurrent protection on a battery bank rated at more
than 2200 CCA or more than 500 Ahr?

,◉ False. "Readily accessible" defines entry into the engine room in
an emergency as dangerous - use a remote battery switch..
Answer: T or F: it is ok to mount a battery switch inside an engine
room, because ABYC startes that it must be located as close to the
batteries as practical.


◉ Overcurrent protection must be located withing 7 inches of the
power source unless contained within a sheath, in which case it may
be up to 40 inches away. If the power source is a battery and the
conductors are sheathed, OC may be up to 72 inches away..
Answer: Explain the "7-40-72" rule


◉ Resetting mechanism cannot overrid over current interrupting
mechanism. (Note: some residential breakers are not trip free).
Answer: What does "trip free" breaker mean?


◉ C. 14.1 V.
Answer: The maximum sustained charging voltage acceptable to
some gell cell battery manufacturers is:
A. 13.8 V
B. 14.5 V
C. 14.1 V
D. 13.2 Vll

,◉ 0.050 points of specific gravity below other cells = bad cell..
Answer: When testing a wet-cell battery with a hydrometer, what
threshold is used to determine a bad cell?


◉ 1.260 - 1.285 (temperature dependent).
Answer: When testing a wet-cell battery with a hydrometer, what
reading indicates a fully charged battery?


◉ 50%.
Answer: When testing a fully charged start battery for capacity with
a load tester, what % of CCA rating should be induced by the load to
test resulting voltage?


◉ C. Between 150% and 200%.
Answer: Most engine-driven alternators are optimally spun at what
percentage of engine RPMs?
A. Between 10% and 50%
B. Less than 10%
C. Between 150% and 200%
D. Greater than 200%


◉ False. the battery charger case shall be tied to the engine negative
terminal/bus, along with the negative output terminal of the battery
charger, not at the battery charger case itself.,.

, Answer: T or F: A battery charger case shall be tied to the DC
negative output terminal at the battery charger.


◉ In case of an internal short to the case, the AC grounding wire
would not carry enough current..
Answer: Why do battery chargers require a separate case
connection to main AC grounding bus and Engine negative / DC
grounding bus?


◉ No smaller than 1 size below the DC current carrying conductors
between the charger and batteries - provided OC protection on
positive DC output is no greater than 135% of DC grounding cable
ampacity and conductor is no smaller than 16 AWG..
Answer: What is the minimal wire size required for a battery
charger case connection to DC ground/engine negative?


◉ Class T fuse rated for appropriate AIC.
Answer: What device is typically found to satisfy the required OC
protection between a battery charger and the batteries?


◉ Batteries will feed back into solar array or wind generator coil
and discharge (possibly damage). Note: many voltage regulators
have integral blocking diodes..
Answer: What may happen to a solar array or wind generator used
to charge batteries without a blocking diode?

Infos sur le Document

Publié le
22 juillet 2026
Nombre de pages
66
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses
$15.99

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
TopGradeInsider
4.1
(9)
Vendu
130
Abonnés
2
Éléments
46214
Dernière vente
18 heures de cela


Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions