RECENT EXAM 2026|2027 ACTUAL COMPLETE REAL
EXAM QUESTIONS AND CORRECT WELL DEFINED
ANSWERS (VERIFIED ANSWERS) ALREADY GRADED
A+ |GUARANTEED SUCCESS!! NEWEST EXAM | JUST
RELEASED!!
What target-filtration combination in analog imaging provides
the best penetration for dense or thick breast? - ANSWER-
Rhodium target with Rhodium filtration
The material used for the exit port of mammography is
necessary because? -
ANSWER-regular glass would harden
the beam
what is used as the port window in mammography units -
ANSWER-beryllium
The intensity of the X-ray beam from the cathode side of the
tube is generally higher because - ANSWER-The heel effect
causes variation of the X-ray beam
The design of the lip of the compression paddle (both height
and angle along the chest wall)affects all the the following
except that it - ANSWER-ensures greater compression of the
anterior breast tissue
,The PRIMARY goal of compression is to - ANSWER-allow
uniform penetration
What features of the high-transmission cellular grid allow these
grids to maintain
equal or less radiation dose to the patient compared with
linear grids? -
ANSWER-they have copper as the strips and air as the
interspace material
The grid ratio can vary in modern mammography units. A
common grid ratio
used is -
ANSWER-4:1
What principal is the target angled allowing a larger area for
the electrons to
strike while maintaining a small elective focal spot -
ANSWER-line focus
principal
the smaller the smaller the target angle the smaller the --- -
ANSWER-focal spot
size
WOTF affects focal spot size
-angle of the anode
-a decrease in SID
-decreasing the size of the collimated beam
,-changing the relationship between the OID and SID - ANSWER-
angle of the anode
in mammography the commonly used focal spot size for
routine work is? -
ANSWER-
o.3mm
WOTF mammograhy QC tests is performed AS
NEEDED
-phantom images
quality
-visual
checklist
-repeat
analysis
-mammography equipment evaluation - ANSWER-
repeat analysis
The general criteria to pass the new ACR DM phantom requires
a MINIMUM of
--- masses -
ANSWER-3
a check of indicated compression thickness is the -
ANSWER-compression
thickness
indicator test
, A check that ensures that the lead interpreting radiologist is
aware of all the QC
tests are being performed at their required
frequency is
-VISUAL CHECKLIST
-FACILITY QC REVIEW
-MEE TEST
-MONITOR QC - ANSWER-FACILITY QC REVIEW
A technologist test that is performed SEMI
annually is the
-phantom image
test
-visual check
list
-compression
force test
-repeat analysis - ANSWER-compression
force test
repeats
are
-images taken during a breast
stereo
-images used for
QC
-images that involve exposure to
the patient