1. A building operator notices that energy consumption has increased
significantly despite stable occupancy levels. Which of the following is
the MOST effective first step in diagnosing the issue?
A. Replace all HVAC equipment
B. Conduct an energy audit and review interval data trends
C. Increase thermostat setpoints across all zones
D. Shut down non-essential systems permanently
B
The most effective first step is to analyze energy data trends and
conduct an energy audit to identify deviations and potential causes
before implementing corrective actions.
,2. Which HVAC control strategy MOST directly reduces energy
consumption during partial load conditions?
A. Constant air volume (CAV) operation
B. Fixed-speed pumping
C. Variable air volume (VAV) system
D. Manual damper adjustment
C
VAV systems adjust airflow based on demand, significantly reducing
fan energy use during partial load conditions.
3. What is the primary purpose of a building energy management system
(BEMS)?
A. Replace mechanical equipment entirely
B. Monitor and optimize building energy performance
C. Eliminate the need for maintenance staff
D. Increase occupancy comfort only
B
A BEMS monitors, controls, and optimizes energy usage across
building systems to improve efficiency and performance.
4. Which of the following BEST describes economizer operation in HVAC
systems?
A. It increases compressor speed during peak cooling
B. It uses outdoor air for free cooling when conditions are favorable
C. It recirculates indoor air to save energy
, D. It preheats air using electric resistance coils
B
Economizers reduce mechanical cooling demand by using cool
outdoor air when conditions permit.
5. Which metric is MOST commonly used to benchmark building energy
performance?
A. Power factor
B. Energy Use Intensity (EUI)
C. Kilowatt demand charge
D. Thermal conductivity
B
EUI measures energy consumption per square foot per year, making
it a standard benchmarking metric.
6. What is the primary function of a Variable Frequency Drive (VFD)?
A. Convert AC to DC power
B. Control motor speed by varying frequency
C. Increase motor voltage permanently
D. Eliminate motor torque
B
VFDs adjust motor speed and torque by varying electrical frequency,
improving energy efficiency in pumps and fans.
7. Which of the following is MOST effective for reducing peak electrical
demand?
, A. Increasing lighting wattage
B. Demand response strategies
C. Running all equipment continuously
D. Eliminating metering systems
B
Demand response reduces peak demand by shifting or shedding
loads during high-cost periods.
8. What is the primary benefit of retro-commissioning a building?
A. Replacing all HVAC systems
B. Improving performance of existing systems without major upgrades
C. Increasing building size
D. Eliminating automation systems
B
Retro-commissioning optimizes existing building systems to restore
efficient operation.
9. Which system is MOST responsible for controlling indoor temperature
zones?
A. Fire alarm system
B. HVAC zoning controls
C. Access control system
D. Elevators
B