1ST EXAM IEC YEAR 2 EXAM | COMPLETE QUESTIONS WITH 100%
RATED EXPERT SOLUTIONS |2026 LATEST UPDATED
Which type of plan shows receptacles? - (answer)power plan
The large-scale adoption of the business computer led to a new form of drafting called -
(answer)Computer-Aided Drafting (CAD)
How many nightlights will be in Wendy's? - (answer)6
Per the Wendy's prints, which contractors) is/are responsible for installing the thermostats in the
fan control panel? - (answer)The electrical contractor provides the thermostats. The HVAC
contractor supplies and installs the thermostat wire.
Pages within a set of prints are numbered according to the type and convention. What is an
example of a naming convention found within a set of prints? - (answer)Fire Protections
Which is size of pipe is NOT used for the storm sewer at Wendy's? - (answer)8"
,Per the Veterinary Center prints, pull stations shall be installed______ from all exit doors -
(answer)5 feet
Per the Veterinary Center prints, which room does NOT have an occupancy sensor? -
(answer)Mechanical Room
Which of the following is the MasterFormat 95® spec division for electrical? - (answer)16
For the Veterinary Center project, what is the diameter of the pole bases for the parking lot
lighting? - (answer)24"
The footing and column schedules are found on which Veterinary Center drawing? -
(answer)Foundation Plan S-02
What kind of notes relate to an entire sheet or set of drawings? - (answer)General Notes
Which of the following statements, that exceed code, are possible specifications of a particular
project? - (answer)All are possible to be found in the specifications.
, How many rooftop units (RTU's) are at the Veterinary Center? - (answer)7
On Wendy's Restaurant Sheet E-3, the receptacle heights shown are ____ - (answer)Center of the
box
For the Wendy's Restaurant project, which of the symbols above represents a Type C site light? -
(answer)III
What are the actual dimensions of a nominal 2 x 6? - (answer)1 1/2" x 5 1/2"
What is the scale of the Veterinary Center Topographical Survey? - (answer)1"= 20'
What size conductors feed the illuminated sign (from LP2 5tc) near the entrance to the Veterinary
Center? - (answer)2 #8, 1 #10
he wall between Bath and the Drying Room in the Veterinary Center is a CMU partition wall.
The wall will be supported at the top with steel angle screwed to the deck every - (answer)4 feet
RATED EXPERT SOLUTIONS |2026 LATEST UPDATED
Which type of plan shows receptacles? - (answer)power plan
The large-scale adoption of the business computer led to a new form of drafting called -
(answer)Computer-Aided Drafting (CAD)
How many nightlights will be in Wendy's? - (answer)6
Per the Wendy's prints, which contractors) is/are responsible for installing the thermostats in the
fan control panel? - (answer)The electrical contractor provides the thermostats. The HVAC
contractor supplies and installs the thermostat wire.
Pages within a set of prints are numbered according to the type and convention. What is an
example of a naming convention found within a set of prints? - (answer)Fire Protections
Which is size of pipe is NOT used for the storm sewer at Wendy's? - (answer)8"
,Per the Veterinary Center prints, pull stations shall be installed______ from all exit doors -
(answer)5 feet
Per the Veterinary Center prints, which room does NOT have an occupancy sensor? -
(answer)Mechanical Room
Which of the following is the MasterFormat 95® spec division for electrical? - (answer)16
For the Veterinary Center project, what is the diameter of the pole bases for the parking lot
lighting? - (answer)24"
The footing and column schedules are found on which Veterinary Center drawing? -
(answer)Foundation Plan S-02
What kind of notes relate to an entire sheet or set of drawings? - (answer)General Notes
Which of the following statements, that exceed code, are possible specifications of a particular
project? - (answer)All are possible to be found in the specifications.
, How many rooftop units (RTU's) are at the Veterinary Center? - (answer)7
On Wendy's Restaurant Sheet E-3, the receptacle heights shown are ____ - (answer)Center of the
box
For the Wendy's Restaurant project, which of the symbols above represents a Type C site light? -
(answer)III
What are the actual dimensions of a nominal 2 x 6? - (answer)1 1/2" x 5 1/2"
What is the scale of the Veterinary Center Topographical Survey? - (answer)1"= 20'
What size conductors feed the illuminated sign (from LP2 5tc) near the entrance to the Veterinary
Center? - (answer)2 #8, 1 #10
he wall between Bath and the Drying Room in the Veterinary Center is a CMU partition wall.
The wall will be supported at the top with steel angle screwed to the deck every - (answer)4 feet