Specialist Exam 1,2and3 – Full Question
Bank with Verified Answers
AWWA Cross-Connection Control Specialist Exam 1
mn mn mn mn mn
1. A cross-connection is defined as:
mn mn mn mn mn
• A) Any physical connection between a potable water system and any non-
mn mn mn mn mn mn mn mn mn mn mn
potable source. mn
• B) Any connection between two different pipe materials.
mn mn mn mn mn mn mn
• C) A connection between a fire sprinkler system and a domestic water line.
mn mn mn mn mn mn mn mn mn mn mn mn
• D) A pipe that crosses over a sewer line.
mn mn mn mn mn mn mn mn
2. Backflow is the unwanted reversal of flow in a piping system. The two main types o
mn mn mn mn mn mn mn mn mn mn mn mn mn mn mn mn
f backflow are:
mn mn
• A) Gravity and Pressure.
mn mn mn
• B) Backpressure and Backsiphonage.
mn mn mn
• C) Direct and Indirect.
mn mn mn
• D) Thermal and Hydraulic.
mn mn mn
3. Backsiphonage occurs when:
mn mn mn
• A) The downstream pressure is greater than the supply pressure.
mn mn mn mn mn mn mn mn mn
• B) A pump is used to increase pressure in the system.
mn mn mn mn mn mn mn mn mn mn
• C) The supply pressure drops below atmospheric pressure, creating a partial vacuum.
mn mn mn mn mn mn mn mn mn mn mn
• D) Water hammer causes a pressure surge.
mn mn mn mn mn mn
4. A hose bib (garden hose) connected to a chemical sprayer without a backflow preve
mn mn mn mn mn mn mn mn mn mn mn mn mn mn
nter is an example of:
mn mn mn mn
, • A) A potential cross-connection and a high health hazard.
mn mn mn mn mn mn mn mn
• B) An indirect waste connection.
mn mn mn mn
• C) An air gap separation.
mn mn mn mn
• D) A reduced pressure zone assembly.
mn mn mn mn mn
5. An air gap separation is considered the most reliable method of backflow preventio
mn mn mn mn mn mn mn mn mn mn mn mn mn
n because:
mn
• A) It is the cheapest method to install.
mn mn mn mn mn mn mn
• B) It provides a physical break between the water supply and the receiving vessel, wit
mn mn mn mn mn mn mn mn mn mn mn mn mn mn
h no moving parts.
mn mn mn
• C) It is the only method approved for all hazards.
mn mn mn mn mn mn mn mn mn
• D) It requires no maintenance.
mn mn mn mn
6. What is the minimum required vertical distance (air gap) between the outlet of a w
mn mn mn mn mn mn mn mn mn mn mn mn mn mn mn
ater supply pipe and the flood-level rim of a fixture?
mn mn mn mn mn mn mn mn mn
• A) At least 1 inch.
mn mn mn mn
• B) At least twice the diameter of the supply pipe.
mn mn mn mn mn mn mn mn mn
• C) A distance equal to the diameter of the supply pipe, but never less than 1 inch.
mn mn mn mn mn mn mn mn mn mn mn mn mn mn mn mn
• D) At least 6 inches.
mn mn mn mn
7. A Reduced Pressure Zone (RPZ) Assembly is used for protection against:
mn mn mn mn mn mn mn mn mn mn mn
• A) Only backsiphonage.
mn mn
• B) Only backpressure.
mn mn
• C) Both backsiphonage and backpressure.
mn mn mn mn
• D) Neither, it is only used for fire systems.
mn mn mn mn mn mn mn mn
8. The key component that distinguishes an RPZ assembly from a Double Check Valve
mn mn mn mn mn mn mn mn mn mn mn mn mn mn
Assembly (DCVA) is the: mn mn mn
, • A) Check Valve.
mn mn
• B) Gate Valve.
mn mn
• C) Relief Valve.
mn mn
• D) Test Cocks.
mn mn
9. Which backflow prevention assembly is best suited for continuous, high-
mn mn mn mn mn mn mn mn mn mn
hazard, non-health hazard applications?
mn mn mn
• A) Atmospheric Vacuum Breaker (AVB).
mn mn mn mn
• B) Double Check Valve Assembly (DCVA).
mn mn mn mn mn
• C) Reduced Pressure Zone Assembly (RPZ).
mn mn mn mn mn
• D) Pressure Vacuum Breaker (PVB).
mn mn mn mn
10. An Atmospheric Vacuum Breaker (AVB) must be installed:
mn mn mn mn mn mn mn mn
• A) At any elevation.
mn mn mn
• B) At least 6 inches above the highest downstream piping or outlet.
mn mn mn mn mn mn mn mn mn mn mn
• C) At least 12 inches above the highest downstream piping or outlet.
mn mn mn mn mn mn mn mn mn mn mn
• D) Below the flood-level rim.
mn mn mn mn
11. A Pressure Vacuum Breaker (PVB) is similar to an AVB but:
mn mn mn mn mn mn mn mn mn mn mn
• A) Is smaller and cheaper.
mn mn mn mn
• B) Can be used under continuous pressure and has spring-loaded check valves.
mn mn mn mn mn mn mn mn mn mn mn
• C) Is only used for underground applications.
mn mn mn mn mn mn
• D) Does not need to be installed above the downstream piping.
mn mn mn mn mn mn mn mn mn mn
12. Which of the following devices is NOT approved for protection against backpressu
mn mn mn mn mn mn mn mn mn mn mn mn
re?
• A) Reduced Pressure Zone (RPZ).
mn mn mn mn
• B) Double Check Valve Assembly (DCVA).
mn mn mn mn mn
, • C) Atmospheric Vacuum Breaker (AVB).
mn mn mn mn
• D) Reduced Pressure Detector Assembly (RPDA).
mn mn mn mn mn
13. A "High Health Hazard" is defined as:
mn mn mn mn mn mn mn
• A) A condition that could cause a minor illness.
mn mn mn mn mn mn mn mn
• B) A condition that could cause death or a major illness to the consumer.
mn mn mn mn mn mn mn mn mn mn mn mn mn
• C) A condition that only affects the taste or odor of the water.
mn mn mn mn mn mn mn mn mn mn mn mn
• D) A condition that only damages plumbing.
mn mn mn mn mn mn
14. The primary purpose of a cross-connection control program is to:
mn mn mn mn mn mn mn mn mn mn
• A) Reduce water consumption.
mn mn mn
• B) Protect the public potable water supply from contamination.
mn mn mn mn mn mn mn mn
• C) Increase water pressure in the distribution system.
mn mn mn mn mn mn mn
• D) Ensure proper drainage of wastewater.
mn mn mn mn mn
15. Who bears the ultimate responsibility for protecting the public water system from
mn mn mn mn mn mn mn mn mn mn mn mn mn
cross-connections?
• A) The plumber who installs the piping.
mn mn mn mn mn mn
• B) The property owner.
mn mn mn
• C) The water purveyor (utility).
mn mn mn mn
• D) The state health department.
mn mn mn mn
16. The "Degree of Hazard" refers to:
mn mn mn mn mn mn
• A) The physical difficulty of installing a backflow preventer.
mn mn mn mn mn mn mn mn
• B) Whether the potential contaminant is toxic (health hazard) or objectionable (non-
mn mn mn mn mn mn mn mn mn mn mn
health hazard). mn
• C) The age of the plumbing system.
mn mn mn mn mn mn
• D) The distance between the cross-connection and the water meter.
mn mn mn mn mn mn mn mn mn