NCCER Comprehensive Resource To Help You Ace Exams Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS Guaranteed Pass First Attempt!! Current Update!! Instant Download Pdf 1. Which Article of the NEC covers grounding? a. Article 110 b. Article 230 c. Article 250 d. Article 300 Correct Answer: c. Article 250 2. Which of the following is a 90-degree explosion-proof fitting? a. GUAT b. GUAL c. LB d. C Correct Answer: b. GUAL 3. What is a dropout plate? a. A plate used to support conduit runs b. A metal plate used to cover cable tray joints c. A metal plate with a curved surface for cable to follow as it passes from the tray d. A grounding plate for cable trays Correct Answer: c. A metal plate with a curved surface for cable to follow as it passes from the tray 4. All of the following are common service voltages in the United States EXCEPT: a. 120/240 V single-phase b. 120/208 V 3-phase, 4-wire c. 277/480 V 3-phase, 4-wire d. 372/575 V 3-phase, 4-wire Correct Answer: d. 372/575 V 3-phase, 4-wire 5. What does a GFCI breaker do? a. Increases circuit voltage b. Regulates motor speed c. Opens a circuit to prevent operation of an electrical device d. Boosts current flow Correct Answer: c. Opens a circuit to prevent operation of an electrical device 6. What will happen when one or more coils in a winding are grounded? a. The motor runs faster b. The motor automatically blows fuses c. The motor becomes more efficient d. The motor reverses direction Correct Answer: b. The motor automatically blows fuses 7. Eight incandescent lighting fixtures are to be installed. Each fixture is 120 volts with a 200-watt lamp. What is the total connected load? a. 10.0 amps b. 12.5 amps c. 13.3 amps d. 16.0 amps Correct Answer: c. 13.3 amps 8. What must be grounded in a bussed gutter if it is used as the main service equipment? a. Phase busbar b. Equipment enclosure c. Neutral busbar d. Conduit body Correct Answer: c. Neutral busbar 9. When wall mounting cable tray, what must be ensured? a. The tray is painted b. The building structure is strong enough to support the tray system c. The tray is grounded at one end only d. The tray is installed vertically Correct Answer: b. The building structure is strong enough to support the tray system 10. What is the purpose of sealing cable ends when reels of cable are in storage? a. To identify cable size b. To prevent abrasion c. To keep moisture from creeping in d. To increase flexibility Correct Answer: c. To keep moisture from creeping in

Show more Read less
Institution
NCCER
Course
NCCER

Content preview

NCCER
Comprehensive Resource To Help You Ace 2026-2027
Exams Includes Frequently Tested Questions With
ELABORATED 100% Correct COMPLETE SOLUTIONS
Guaranteed Pass First Attempt!! Current Update!!
Instant Download Pdf


1. Which Article of the NEC covers grounding?
a. Article 110
b. Article 230
c. Article 250
d. Article 300
Correct Answer: c. Article 250

2. Which of the following is a 90-degree explosion-proof fitting?
a. GUAT
b. GUAL
c. LB
d. C
Correct Answer: b. GUAL



3. What is a dropout plate?
a. A plate used to support conduit runs
b. A metal plate used to cover cable tray joints
c. A metal plate with a curved surface for cable to follow as it passes from the tray
d. A grounding plate for cable trays
Correct Answer: c. A metal plate with a curved surface for cable to follow as it passes
from the tray

4. All of the following are common service voltages in the United States EXCEPT:
a. 120/240 V single-phase
b. 120/208 V 3-phase, 4-wire
c. 277/480 V 3-phase, 4-wire

, d. 372/575 V 3-phase, 4-wire
Correct Answer: d. 372/575 V 3-phase, 4-wire



5. What does a GFCI breaker do?
a. Increases circuit voltage
b. Regulates motor speed
c. Opens a circuit to prevent operation of an electrical device
d. Boosts current flow
Correct Answer: c. Opens a circuit to prevent operation of an electrical device

6. What will happen when one or more coils in a winding are grounded?
a. The motor runs faster
b. The motor automatically blows fuses
c. The motor becomes more efficient
d. The motor reverses direction
Correct Answer: b. The motor automatically blows fuses



7. Eight incandescent lighting fixtures are to be installed. Each fixture is 120 volts with a
200-watt lamp. What is the total connected load?
a. 10.0 amps
b. 12.5 amps
c. 13.3 amps
d. 16.0 amps
Correct Answer: c. 13.3 amps

8. What must be grounded in a bussed gutter if it is used as the main service equipment?
a. Phase busbar
b. Equipment enclosure
c. Neutral busbar
d. Conduit body
Correct Answer: c. Neutral busbar



9. When wall mounting cable tray, what must be ensured?
a. The tray is painted

, b. The building structure is strong enough to support the tray system
c. The tray is grounded at one end only
d. The tray is installed vertically
Correct Answer: b. The building structure is strong enough to support the tray
system

10. What is the purpose of sealing cable ends when reels of cable are in storage?
a. To identify cable size
b. To prevent abrasion
c. To keep moisture from creeping in
d. To increase flexibility
Correct Answer: c. To keep moisture from creeping in



11. The outer covering on liquid-tight flexible metal conduit is used for:
a. Electrical insulation only
b. A moisture seal
c. Mechanical grounding
d. Voltage regulation
Correct Answer: b. A moisture seal

12. A good electrical connection should:
a. Be mechanically secure only
b. Be electrically secure only
c. Be mechanically and electrically secure
d. Have low mechanical strength
Correct Answer: c. Be mechanically and electrically secure



13. What symbol is normally used for a duplex receptacle?
a. Square with a diagonal line
b. Triangle with a circle
c. Circle with two parallel lines drawn through it
d. Circle with one line through it
Correct Answer: c. Circle with two parallel lines drawn through it

, 14. Disconnecting means are covered in:
a. NEC Article 250
b. NEC Section 110-22
c. NEC Article 300
d. NEC Section 430-52
Correct Answer: b. NEC Section 110-22



15. In relation to switches, the term "throw" refers to the:
a. Voltage rating
b. Number of poles
c. Number of internal operations that a switch can perform
d. Current rating
Correct Answer: c. Number of internal operations that a switch can perform

16. A 3-phase, 4-wire, 480-volt service requires how many current transformers?
a. 1
b. 2
c. 3
d. 4
Correct Answer: c. 3



17. Service conductors and equipment are covered in:
a. NEC Article 110
b. NEC Article 230
c. NEC Article 250
d. NEC Article 300
Correct Answer: b. NEC Article 230

18. The NEC requires that all receptacles installed on 15-amp and 20-amp branch circuits be
what type of receptacles?
a. Tamper-resistant
b. Hospital grade
c. Grounding receptacles
d. Locking type
Correct Answer: c. Grounding receptacles

Written for

Institution
NCCER
Course
NCCER

Document information

Uploaded on
June 15, 2026
Number of pages
33
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy Harvard University
View profile
Follow You need to be logged in order to follow users or courses
Sold
756
Member since
3 year
Number of followers
431
Documents
8150
Last sold
1 week ago
EN.CY.CLO.PE.DI.A

As a Career Tutor, I understand the pressure of managing demanding coursework, exams, and practical requirements across multiple disciplines. These professionally organized revision materials are designed to support students in nursing, healthcare administration, business, information systems, Engineering, health, IT, or trade courses management programs by simplifying complex concepts and reinforcing high-yield academic content. The materials are developed to help students: Understand core theories and practical applications across Multiple Disciplines Review exam relevant content aligned with undergraduate and graduate curriculam To Strengthen critical thinking, analytical reasoning, and decision-making skills Save time with clear, structured summaries instead of overwhelming textbooks Prepare efficiently for tests, assignments, case studies, and professional exams Each resource is created with academic standards in mind, integrating real world examples, industry terminology, and evidence based concepts commonly required in professional programs. Whether you are studying nursing fundamentals, healthcare management, information systems, project management, business strategy, Engineering these materials provide focused, reliable support for academic success. These revision guides are ideal for: Nursing and allied health students Healthcare administration and public health students Business, MBA, and management students Information technology and information systems students, engineering, business, IT, or trade courses If you are looking for clear, student-friendly, exam-focused revision materials that support multiple career pathways, these resources are designed to help you study smarter, perform better, and stay confident throughout your academic journey. WISH YOU SUCCESS!!

Read more Read less
3.7

112 reviews

5
56
4
14
3
17
2
6
1
19

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions