Radiation monitoring of personnel is required when what percentage of
the annual occupational effective dose limit is likely to be received -
ANSWER- 10%


The conventional (British system) radiation unit to express radiation
intensity in the air - ANSWER- Roentgen


The conventional (British system) unit commonly used to report
occupational dose to radiation workers in the United States is the -
ANSWER- rem


What is the conventional (British system) radiation unit of absorbed
dose - ANSWER- Rad


According to the Bergonie-Tribondeau law, the following types of cells
are most radiosensitive - ANSWER- embryonic tissue cells

,2|Page


Type of x-ray photon interaction with the body is primarily responsible
for the radiation dose absorbed by the patient - ANSWER- Photoelectric


The NCRP (report #102) recommendation for lead equivalency of
aprons used for personnel protection - ANSWER- 0.5 mm


Erythema as it relates to radiation exposure - ANSWER- reddening of
the skin caused by a high radiation dose


The guiding philosophy of radiation protection - ANSWER- ALARA--
as low as reasonably achievable


The following statements reflects current scientific opinion regarding the
effects of diagnostic levels of ionizing radiation - ANSWER- There is an
increased risk of cancer, leukemia, birth defects, and cataracts


The following changes will decrease patient dose - ANSWER- using a
faster-speed class imaging system
Increasing the grid ratio to a 16:1 ratio


When radiation exposure occurs during pregnancy, the greatest risk of
birth defects occurs when the exposure - ANSWER- exceeds 5 rad to the
uterus
Occurs within the first trimester of pregnancy

, 3|Page


At what kvp levels do Compton interactions occur - ANSWER- they
occur throughout the diagnostic radiology kvp range


The principal source of scatter radiation in radiography - ANSWER-
The IR


The four essentials elements required for x-ray production - ANSWER-
A target, a vacuum, an electron source, and a high potential difference


The greatest portion of the x-ray beam is made up of - ANSWER-
Bremsstrahlung radiation


The penetrating power of the x-ray beam is controlled by varying the -
ANSWER- kilovoltage (kvp)


The following functions involve the autotransformer - ANSWER- kvp
selection


What is the IR that is used for computed radiography - ANSWER-
Photostimulable phosphor (PSP) plate


Nearly all new x-ray machines manufactured today use
_________________ generators - ANSWER- High-frequency


The target of the x-ray tube is made of - ANSWER- tungsten

Documentinformatie

Geüpload op
6 juni 2026
Aantal pagina's
30
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$22.99

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
impressivetutor
4.8
(1821)
Verkocht
665
Volgers
377
Items
3729
Laatst verkocht
16 uur geleden


Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen