SUPERVISION OF FOAM-WATER
SPRINKLER SYSTEMS 2026
EXPERT VERIFED ACE THE
TEST
Fire Guard - ANSWER ✔✔The impairment coordinator or other
building staff trained and knowledgeable in conducting a fire watch may
conduct a fire watch in lieu of a fire guard during the initial 4 hours of a
planned removal from service, or after discovery of an unplanned out-
ofservice condition, provided that the floor or area in which the fire
protection system is out of service does not exceed 50,000 square feet.
,A sufficient number of fire guards shall be provided such that each floor
or area in which the fire protection system is out of service is patrolled at
least once an hour.
Record keeping - ANSWER ✔✔Records of all system inspections,
tests, servicing and other maintenance required by this NYC Fire Code,
the NYC Fire Rules or the referenced standards shall be maintained on
the premises or other approved location for a minimum of 3 years and
made available for inspection by any Fire Department representative.
(FC 901.6.2)
S-12/S-15 COF - ANSWER ✔✔holder - visual inspections only,
proper notification and record inspection results for examination by
FDNY. S-12: Water-based fire protection systems. S-15: Foam-water
suppression systems and water-based fire protection systems.
S-12/S-15* COF - ANSWER ✔✔holder employed by a site-specific
building owner with the following certifications: Refrigeration Operating
Engineer (Refrigeration Q-99 or Q-01), High Pressure Operating
Engineer and NYS High Pressure Operating Engineer are permitted to
perform visual inspections, test notification appliances, perform daily and
weekly routine maintenance and record all inspection, testing and
maintenance results for examination by FDNY.
, Master Plumber (MP) w - ANSWER ✔✔with S-12/S-15 - is limited to
residential (R) occupancies 30 sprinkler heads or less without a booster
pump.
ALARM NOTIFICATION APPLIANCE - ANSWER ✔✔A fire alarm
system component, such as a bell, horn, speaker, light, text display or
vibration device that issues an audible, tactile, and/or visual alert.
ALARM SIGNAL - ANSWER ✔✔A signal indicating an emergency
requiring immediate action, such as a signal indicative of fire.
ANTIFREEZE SPRINKLER SYSTEM - ANSWER ✔✔A wet pipe
sprinkler system employing automatic sprinklers that are attached to a
piping system that contains an antifreeze solution and is connected to a
water supply. The antifreeze solution is discharged, followed by water,
immediately upon operation of sprinklers opened by heat from a fire.
AUTOMATIC BALL DRIP - ANSWER ✔✔An automatic drain valve
horizontally installed at the low point in the piping between the lower
check valve and the Fire Department connection of automatic sprinkler
systems. Water pressure from a Fire Department pumper automatically
closes this valve. It automatically re-opens when pressure ceases,
permitting this piping to drain and thereby preventing freezing.
COPYRIGHT©PROFFKERRYMARTIN 2025/2026. YEAR PUBLISHED 2026. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE.