Attenuation - CORRECT ANSWER -The Decrease in magnitude or power loss of a signal.



Decibels, dB - CORRECT ANSWER -Unit of measurement for attenuation.



American Wire Gauge (AWG) - CORRECT ANSWER -
The numerical system for designating wire diameter.



inverse relationship - CORRECT ANSWER -
American Wire Gauge numbers have this relationship to the wire size.



Balanced Twisted-Pair - CORRECT ANSWER -
Type of wiring in which 2 conductors of a single circuit are twisted together in order to minimiz
e EMI



V=I*R - CORRECT ANSWER -The formula relation between Voltage, impedance, and resistance.



Capacitance - CORRECT ANSWER -
Measured in Farads, causes a voltage difference between two wires when they are separated b
y insulation



Durability - CORRECT ANSWER -
Connector's ability to survive hundreds of insertions and withdrawls



Impedance - CORRECT ANSWER -
Combined effects of resistance, inductive reactance, and capacitive reactance of a circuit. (Z)

,STP (shielded) and UTP (Unshielded) - CORRECT ANSWER -
The two types of Balanced Twisted Pair cable



100 Ohms at 100 MHz - CORRECT ANSWER -
Nominal characteristic impedance of balanced Twisted-pair cables



100 MHz - CORRECT ANSWER -Cat 5e UTP has transmission characteristics up to:



Crosstalk - CORRECT ANSWER -
The unwanted transfer of a signal's electromagnetic energy from one or more circuits to other
circuits



Shielded, Unshielded, and Cat 7a - CORRECT ANSWER -The three types of balanced twisted-
pair modular connectors



TIA-568A and TIA-568B - CORRECT ANSWER -The two standards-
compliant wiring schemes for 8P8C modular connectors



X - CORRECT ANSWER -The designation used for a multi-line connector



Serial-11 - CORRECT ANSWER -Coaxial Cable type used in video backbone distribution



75 Ohms - CORRECT ANSWER -The characteristic impedance of a series-6 Coaxial Cable



F-type Connector - CORRECT ANSWER -
Type of Coaxial connector that cannot be used with stranded center conductor

,Screw-on - CORRECT ANSWER -
Type of BNC connector that is NOT recommended for any installation



Code - CORRECT ANSWER -
The purpose of is to ensure the safety during the installation and use of materials, compon
ents, fixtures, systems, premises, and related subjects



Standard - CORRECT ANSWER -
The purpose of is to improve the quality, function, performance, repeatability or some oth
er facet of an item



ANSI/TIA-568.0 - CORRECT ANSWER -
This ANSI/TIA standard is the foundation for premise telecommunication cabling infrastructure;
enables the planning and installation of a structured cabling system for all types of customer p
remises



ANSI/TIA-606 - CORRECT ANSWER -
This ANSI/TIA standard contains administrative information, such as labeling requirements and
recommendations for the components of a structured cabling system



ANSI/TIA-607 - CORRECT ANSWER -
This ANSI/TIA standard provides recommendations and requirements related to Bonding and G
rounding



First Level Backbone - CORRECT ANSWER -
This level of Backbone cabling is between the MC and the IC



First Level Backbone - CORRECT ANSWER -
This level of Backbone cabling is between the MC and the HC or IC

, Second Level Backbone - CORRECT ANSWER -
This level of Backbone cabling is between the IC and the HC



To distribute signal from the Horizontal Cross-connect in the TR to the work area -
CORRECT ANSWER -This is the purpose of horizontal Cabling



2 Cables - CORRECT ANSWER -
This is the minimum number of cables to be installed/ran to each work area



Orange - CORRECT ANSWER -This color is used to denote a cable demarcation point



Green - CORRECT ANSWER -This color is used to denote Network connections



Purple - CORRECT ANSWER -This color is used to denote Common Equipment



White - CORRECT ANSWER -This color is used to denote first-level backbone cabling



Gray - CORRECT ANSWER -This color is used to denote second-level backbone cabling



Blue - CORRECT ANSWER -This color is used to denote Horizontal Cabling



Brown - CORRECT ANSWER -This color is used to denote Inter-Building backbone cabling



Yellow - CORRECT ANSWER -This color is used to denote misc. systems, like alarm circuits



Red - CORRECT ANSWER -This color is used to denote systems reserved for future used

Written for

Institution
BICSI
Course
BICSI

Document information

Uploaded on
June 2, 2026
Number of pages
42
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
BICSI
-
9 2026
$ 51.35 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EliteStudyHub Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
72
Member since
1 year
Number of followers
5
Documents
8724
Last sold
3 days ago
Elite Study Hub

I provide high-quality, well-organized academic study materials designed to help students excel in their exams and coursework. My resources include test banks, study guides, solution manuals, and practice exams across nursing, business, psychology, and health sciences. Each document is carefully structured, up-to-date, and focused on key concepts, exam preparation, and real understanding—not just memorization. I aim to make studying more efficient and help you achieve top grades with confidence. What You’ll Find in My Store: Test Banks (All Chapters Covered) Study Guides & Review Notes Practice Exams with Answers NCLEX, HESI, ATI Preparation Materials Case Studies & Clinical Scenarios Solution Manuals (Step-by-step explanations) Why Choose My Materials? ✔ Latest updates (2024–2027 content) ✔ Clear explanations & structured format ✔ Exam-focused and easy to follow ✔ Trusted by students for high performance Subjects Covered: Nursing | Pharmacology | Psychology | Business | Accounting | Biology | Public Health | And more Support: If you have any questions or need help finding specific materials, feel free to reach out—I’m here to help you succeed.

Read more Read less
2.2

9 reviews

5
2
4
0
3
1
2
1
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions