The operable part of a manually actuated alarm initiating
device shall be not less than ____ inches AFF. - ANSWER-42
inches


Consider the use of grounding electrodes. Rod and pipe
electrodes shall not be less than____ feet in length? - ANSWER-
8 feet


Smoke detectors should not be located in a direct airflow or
closer than ____ inches from an air supply diffuser or return air
opening? - ANSWER-36 inches


Which of the following is an acceptable method for performing
a smoke entry test of a spot type smoke detector? - ANSWER-
Listed and labeled smoke product acceptable to the
manufacturer.


What are the general care instructions for injuries to muscle,
bone and joints? -
ANSWER-Rest, Immortalize, Apply cold


Which of the following tests are required for system type smoke
detectors in one and two family dwelling? - ANSWER-
Functional test per manufacturer's instructions


A person has sustained a burn from a portable heater. Which of
the following should not be done when treating the burn? -
ANSWER-Apply Ice


NICET

,What is the periodic inspection frequency of sealed lead acid
batteries? - ANSWER-Semiannually
When installing fire alarm cable in a hoistway, the cable shall
be installed using____ . - ANSWER-EMT, IMC, RMC


Fixed temperature, non restorable spot type heat detectors
must be replaced ____ years from initial installation, or have 2
detectors per 100 laboratory tested? - ANSWER-15 years


Prior to installating fire alarm system cabling, it is noted that
the area above a drop ceiling does not have return air ducts.
The whole space is used as an environmental air return. What
type of fire alarm cabling is best suited for this application? -
ANSWER-FPLP


When performing a charger test for sealed lead acid batteries,
the voltage should be 2.3 volts per cell +/- 0.02 volts? -
ANSWER-2.3


According to NFPA 72, the sound pressure level of audible
appliances shall be tested upon A&B? - ANSWER-Initial
acceptance, Reacceptance


While conducting acceptance testing on audible notification,
the sound pressure level is measured at 12 db above the
average ambient sound level in the building. According to NFPA
72 the minimum sound level for audible notification appliances
in public mode shall be at last____ above the average ambient
sound level? - ANSWER-9 above the average ambient sound
level




NICET

, Which of the following is a symptom of a heart attack? -
ANSWER-Chest pain, Difficulty breathing


A fire alarm system strobe flashes at a rate of 1 flash every
second. According to NFPA 72, the minimum flash rate for a
visible notification appliance shall not be less than____ flash(es)
per second? - ANSWER-1 flash
A machine on a job site requires safety training before use. The
machine does not have a lockout feature. What other options is
acceptable? - ANSWER-Tag out the machine


While conducting a charger test on sealed lead acid batteries, it
is important to ensure the batteries are fully connected to the
charger, measure the voltage across the batteries with a
voltmeter. Verify the voltage is ____ volts per cell? - ANSWER-
2.30 volts


Consider the installation of Ridgid Metal Conduit (RMC). Where
conduit is threaded in the field, a standard cutting die with a 1
inch ____ taper shall be used? - ANSWER-16 taper


While conducting fire alarm systems work, a splice in a
notification circuit ia required. According to NFPA 70, cable
splices shall. Be made in ____? - ANSWER-Boxes, Enclosures,
Fire Alarm device


The amount of FPLR cable is not sufficient to finish the wiring
for the installation of the fire alarm system? What typ of cable
does the code permit to be used as a substitute? - ANSWER-
FPLP


The branch circuit supplying the fire alarm equipment(s) shall
be permitted to supply____? - ANSWER-No other loads



NICET

Document information

Uploaded on
May 8, 2026
Number of pages
17
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$21.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Examdoctor1
3.7
(6)
Sold
33
Followers
12
Items
2986
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions