Michigan Journeyman Electrical Sign Contractor License Practice Guide 80 Questions and Verified Solutions Exam 2026/2027 1. Where PV system DC circuits are run inside a building, they shall be contained in metal race ways ,____ or metal enclosures from the point of penetration of the surface of the building to the readily accessible disconnecting means. - Correct Answer-Type MC cable 690.31.G 2. Unless specifically listed and marked for the location, the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than___ inches above the grade level for outdoor locations. - Correct Answer-24' 625.50 3. Unless specifically listed and marked for the location, the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than___ inches above the floor level for indoor locations. - Correct Answer-18" 625.50 4. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the vehicle washing area of a carwash shall be listed and so identified as___ type. - Correct Answer-weather resistant 406.9.B1 5. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the vehicle washing area of a carwash shall have an enclosure that is____ whether or not the attachment plug cap is inserted - Correct Answer-weather proof 406.9.B 6. An individual, other than an individual who is licensed under this article and___ and working under the direction of a holder of an electrical contractor's license, shall not in any manner undertake to execute any electrical wiring. - Correct Answer-employed by PA.407 339.5737 7. The ratio of electrical journeyman or master electricians to registered apprentice electricians shall be on the basis of___ electrical journeyman or master electricians to no more than___ registered apprentice electricians. - Correct Answer-1 to 3 PA.407 339.5717 sec 717.3 8. Who can obtain a sign specialty contractor's license? - Correct Answer-an individual whom holds a sign specialist license Michigan Michigan 9. Where fuses rated___ amperes or higher are installed, the fuse shall have a clearing time of 0.07 seconds or less at the available arcing current. - Correct Answer-1200amps 240.67.B 10. A meeting room that is at least 12 feet wide and has a floor area of at least 215 square feet shall have at least___ receptacle outlet(s) located in the floor at a distance not less than 6 feet from any fixed wall for each 215 square feet or major portion of floor space. - Correct Answer-1 210.71.B2 11. For a commercial building the service disconnecting means shall have a rating of not less than___ amperes - Correct Answer-60amps 230.79.D 12. The small appliance branch circuit may also provide a receptacle to provide power for supplemental equipment and lighting on____ - Correct Answer-gas fired ranges or ovens 210.50.B2 13. Where type NM cable is fastened within___ inches of the box securing the cable to the box shall not be required. - Correct Answer-12" 314.17 exc C 14. Pool associated motors shall be permitted to employ cord and plug connections. The flexible cord shall___? - Correct Answer-not exceed 3' in length 680.8.A 15. The length of the cord for a built-in dishwasher shall be___? - Correct Answer-3' to 6.5' 422.16.B.2.3 16. All 15 and 20-ampere, 125 and 250-volt non-locking type receptacles shall be listed tamper resistant receptacles when installed in? - Correct Answer-elementary schools 17. A 1-inch conduit contains three 3-wire circuits. All conductors are # 10 TW. Each circuit consists of two phase conductors, one neutral conductor that carries only the unbalanced current, and one equipment grounding conductor. The maximum ampacity of each phase conductor is___ amperes - Correct Answer-30amps 18. A kiln rated 6000 watts, 208 volts, 3 phase draws___ amperes. - Correct Answer 16.67amps 19. An Expansion joint is required for PVC conduit. When the temperature changes from -5° to 100°F, the thermal expansion for 100 feet of Rigid PVC conduit is___ inches - Correct Answer-4.26 t352.44 20. The allowable ampacity of a #12 AWG THHN copper conductor is___ a. - Correct Answer-30a 21. The maximum overcurrent protection for a circuit containing #12 AWG THHN copper conductors is___ amperes - Correct Answer-20a small conductor rule 240.4.D5 Michigan Michigan 22. There are six conductors in a raceway connected to 75® C rated breakers. Each wire has a 70 amp load using THHN conductors. The minimum size conductors used are #___AWG - Correct Answer-4awg 23. The maximum spacing between supports for 2" PVC is___ feet. - Correct Answer-5' t352.30 24. Where multiple Rod type electrodes are installed they shall not be less than___ feet apart. - Correct Answer-6' apart 250.53.A3 25. If a single rod, pipe, or plate electrode has a resistance to earth of___ ohms or less, the supplemental electrode shall not be required. - Correct Answer-25ohms 250.53.A2 exc 26. A grounding electrode conductor connected to a rod type electrode shall not be required to be larger than___ copper wire - Correct Answer-6awg 250.66.A 27. A grounding electrode conductor connected to a concrete encased electrode shall not be required to be larger than___awg copper wire - Correct Answer-4awg 250.66.B 28. Rod type electrodes shall not be less than___ feet in length - Correct Answer-8' 250.50.A5 29. The volume allowance required for a #12 AWG THHN copper conductor is___ cubic inches - Correct Answer-2.25" t314.16.B 30. What size metal box (with internal clamps) is needed for the installation of two 3conductor/#10AWG w/ground? - Correct Answer-4"x 1.5" square t314.16.B/A 31. What size rigid metal conduit is needed for the installation of 6 #4 A WG THHN copper conductors? - Correct Answer-1 1/4" Chp 9 t7 32. Where more than two conductors are installed in a conduit, the conduit shall be permitted to be filled to___percent of it's cross-sectional area - Correct Answer-40% 33. What is the total area in inches squared of 3 - #4 AWG THHN copper conductors and 5 - #6 AWG TW copper conductors - Correct Answer-.6102" Chp 9 t5 34. What is the minimum size EMT conduit is needed for the installation of 3 - #4 AWG THHN copper conductors and 5 - #6 AWG TW copper conductors - Correct Answer-1.5" 35. What is the minimum size EMT conduit 22" in length that is needed for the installation of 3 - #4 A WG THHN copper conductors and 5 - #6 A WG TW copper conductors - Correct Answer-1.25" Chp9 t5 60% Michigan Michigan 36. What is the full load current of a 40 Horsepower, 480 volt, 3-phase wound rotor motor? - Correct Answer-52amps 430.250 37. What size dual element (time delay) fuse is need for a 40 Horsepower, 480 volt, 3 phase wound rotor motor? - Correct Answer-80amps 430.52.C exc 1 - round up 38. What size THWN copper conductors are nedded for a 40 Horsepower, 480 volt, 3 phase wound rotor motor? - Correct Answer-6awg using 75 39. What is the maximum size inverse time circuit breaker needed for a 25 horsepower, 480 volt, 3 phase, squirrel cage, code letter D motor - Correct Answer-90a round up for standard size 40. What is the maximum size nontime delay fuse needed for a 25 horsepower, 480 volt, 3 phase, squirrel cage, code letter E motor - Correct Answer-110amps standard fuse size 41. In addition to the number of branch circuits required, in dwelling units,___ or more small-appliance branch circuits shall be provided. - Correct Answer-2 210.11.C1 42. In addition to the number of branch circuits required, in dwelling units, at least___ 120 volt, 20 ampere branch circuit shall be installed to supply receptacle outlets in attached garages and detached garages with electrical power. - Correct Answer-1 210.C4 43. Electrical equipment shall be installed - Correct Answer-neat and workmanlike manner 110.12 44. A Delta High-Leg shall be durably and permanently marked by an outer finish that is___ in color or by other effective means. - Correct Answer-orange 110.15 45. Isolated ground receptacles shall be identified by a___ located on the face of the receptacle - Correct Answer-orange triangle 406.3.D 46. Receptacles that are controlled for by an automatic control device for the purpose of energy management shall be marked with the word(s)___? - Correct Answer-controlled 406.3.E 47. What is the box fill requirement for a box that has three 12-3 w/G, NM cable, with one device, two Romex connectors and three clamps? - Correct Answer-29.25" t314.16.B 48. A 200 amp residential service uses 2/0 AWG copper service entrance conductors, the minimum size grounding electrode conductor is___ AWG copper - Correct Answer 4awg t250.66 Michigan Michigan 49. Two conduits installed in parallel contain 4 - 500KCMIL THN copper conductors, the neutral conductor carries only the unbalanced current from other conductors of the same circuit, what size overcurrent protection with 75°C terminals is needed? - Correct Answer-800 amp rule 50. Four conduits installed in parallel contain 4 - 500KCMIL THHN copper conductors, the neutral conductor carries only the unbalanced current from other conductors of the same circuit, what size overcurrent protection with 75°C terminals is needed? - Correct Answer-1200a t240.6.A 240.4.C 51. The cross-sectional area of the conductors permitted in a seal shall not exceed___ percent of the cross-sectional area of the rigid metal conduit, unless the seal is specially listed for a higher % of conductor fill. - Correct Answer-25% 501.15.C6 52. The minimum size service entrance conductor for a 100-amp mobile home service is___awg copper. - Correct Answer-4awg p.800 Annex D 53. The minimum size Aluminum service entrance conductors for a 200- amp residential service is. - Correct Answer-4/0awg p.800 Annex D 54. Class 1 Power-Limited circuits shall be supplied from a source that has a rated output of not more than___ volts - Correct Answer-30v 725.41.A 55. Class 1 Power-Limited circuits shall be supplied from a source that has a rated output of not more than___ volt-amperes. - Correct Answer-1000va 725.41 56. Class 1 remote control and signaling circuits shall not exceed___ volts. - Correct Answer-600v 725.41.B 57. The power output of Class I remote control and signaling circuits shall not___? - Correct Answer-be required to be limited 725.41.B 58. The insulation for communications wires other than the outer conductor of coaxial cable shall be rated for___ volts minimum - Correct Answer-300v 59. When calculating box fill, the volume allowance for a #10 AWG THWN copper conductor is. - Correct Answer-2.5 cubic inches t314.16.B 60. How many hours notice are required for an electrical inspection? - Correct Answer-a reasonable amount of time Part 8 61. What is the current draw for a 6800 watt, 240 volt, 3 phase electric kiln? - Correct Answer-16.38a 62. Equipment must be inspected by the electrical inspector having jurisdiction, and approved before it can be___? - Correct Answer-concealed Michigan Michigan 63. What is the current for a 4980 watt water heater at 208 volts, 3-phase? - Correct Answer-13.84a 64. An incandescent lamp for general use on lighting branch circuits shall not be equipped with a___ base rated over 300 watts - Correct Answer-medium 410.103 65. An incandescent lamp for general use on lighting branch circuits shall not be equipped with a___ base rated over 1500 watts? - Correct Answer-mogul 410.103 66. An incandescent lamp for general use on lighting branch circuits shall be equipped with a___ base or other device if rated over 1500 watts - Correct Answer-special 410.103 67. What is the allowable ampacity of 6 - #12 THHN current carrying conductors installed in EMT? - Correct Answer-24 derate 80% 68. To change direction of rotation on a 3-phase motor - Correct Answer-swap any 2 leads 69. A___ has a coil, plunger, metal frame and push/pull action. - Correct Answer solenoid 70. conduit nipples not exceeding___ inches in length, can be filled to 60% without derating - Correct Answer-24" 71. Thermal insulation shall not be installed within___ inch(es) of recessed fixtures. - Correct Answer-3" 410.116.B 72. The volt-ampere rating of a device that draws 10 amperes on a 120 Volt circuit is___? - Correct Answer-1200va 73. The volt ampere rating of a device that draws 20 amperes on a 480 Volt, 3 phase circuit is___ VA? - Correct Answer-16,608va (I*E*1.73) 74. The current flow for a device rated 5000 watt, 120 volts, single phase, is___ amperes? - Correct Answer-41.67a (P/I) 75. The current flow on a device rated 5000 watts, 480 volt, 3 phase is___ amps. - Correct Answer-6.02a P/(E*1.73)=I 76. The allowable ampacity of 2 conductor/#12 NM (romex) cable is___ amps. - Correct Answer-20a 77. Furnaces shall be supplied by a(n)___ branch circuit. - Correct Answer-individual branch circuit Michigan 78. Round boxes shall not be used where conduits or connectors fasten to the___ of the box. - Correct Answer-side 79. Boxes used for receptacles in the floor shall be ___? - Correct Answer-listed for the application 80. A single non-motor operated appliance of 13.4 amps shall have overcurrent protection not to exceed___ percent of the appliance rating. - Correct Answer-100% Michigan

Content preview

Michigan




Michigan Journeyman Electrical Sign
Contractor License Practice Guide 80
Questions and Verified Solutions Exam
2026/2027

1. Where PV system DC circuits are run inside a building, they shall be contained in
metal race ways ,____ or metal enclosures from the point of penetration of the surface
of the building to the readily accessible disconnecting means. - Correct Answer-Type
MC cable 690.31.G

2. Unless specifically listed and marked for the location, the coupling means of the
electric vehicle supply equipment shall be stored or located at a height of not less
than___ inches above the grade level for outdoor locations. - Correct Answer-24' 625.50

3. Unless specifically listed and marked for the location, the coupling means of the
electric vehicle supply equipment shall be stored or located at a height of not less
than___ inches above the floor level for indoor locations. - Correct Answer-18" 625.50

4. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the vehicle
washing area of a carwash shall be listed and so identified as___ type. - Correct
Answer-weather resistant 406.9.B1

5. All 15 and 20 ampere, 125 volt non locking type receptacles installed in the vehicle
washing area of a carwash shall have an enclosure that is____ whether or not the
attachment plug cap is inserted - Correct Answer-weather proof 406.9.B

6. An individual, other than an individual who is licensed under this article and___ and
working under the direction of a holder of an electrical contractor's license, shall not in
any manner undertake to execute any electrical wiring. - Correct Answer-employed by
PA.407 339.5737

7. The ratio of electrical journeyman or master electricians to registered apprentice
electricians shall be on the basis of___ electrical journeyman or master electricians to
no more than___ registered apprentice electricians. - Correct Answer-1 to 3 PA.407
339.5717 sec 717.3

8. Who can obtain a sign specialty contractor's license? - Correct Answer-an individual
whom holds a sign specialist license

Michigan

, Michigan



9. Where fuses rated___ amperes or higher are installed, the fuse shall have a clearing
time of 0.07 seconds or less at the available arcing current. - Correct Answer-1200amps
240.67.B

10. A meeting room that is at least 12 feet wide and has a floor area of at least 215
square feet shall have at least___ receptacle outlet(s) located in the floor at a distance
not less than 6 feet from any fixed wall for each 215 square feet or major portion of floor
space. - Correct Answer-1 210.71.B2

11. For a commercial building the service disconnecting means shall have a rating of
not less than___ amperes - Correct Answer-60amps 230.79.D

12. The small appliance branch circuit may also provide a receptacle to provide power
for supplemental equipment and lighting on____ - Correct Answer-gas fired ranges or
ovens 210.50.B2

13. Where type NM cable is fastened within___ inches of the box securing the cable to
the box shall not be required. - Correct Answer-12" 314.17 exc C

14. Pool associated motors shall be permitted to employ cord and plug connections.
The flexible cord shall___? - Correct Answer-not exceed 3' in length 680.8.A

15. The length of the cord for a built-in dishwasher shall be___? - Correct Answer-3' to
6.5' 422.16.B.2.3

16. All 15 and 20-ampere, 125 and 250-volt non-locking type receptacles shall be listed
tamper resistant receptacles when installed in? - Correct Answer-elementary schools

17. A 1-inch conduit contains three 3-wire circuits. All conductors are # 10 TW. Each
circuit consists of two phase conductors, one neutral conductor that carries only the
unbalanced current, and one equipment grounding conductor. The maximum ampacity
of each phase conductor is___ amperes - Correct Answer-30amps

18. A kiln rated 6000 watts, 208 volts, 3 phase draws___ amperes. - Correct Answer-
16.67amps

19. An Expansion joint is required for PVC conduit. When the temperature changes
from -5° to 100°F, the thermal expansion for 100 feet of Rigid PVC conduit is___ inches
- Correct Answer-4.26 t352.44

20. The allowable ampacity of a #12 AWG THHN copper conductor is___ a. - Correct
Answer-30a

21. The maximum overcurrent protection for a circuit containing #12 AWG THHN
copper conductors is___ amperes - Correct Answer-20a small conductor rule 240.4.D5

Michigan

Document information

Uploaded on
April 23, 2026
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
AlexScorer
2.5
(2)
Sold
10
Followers
0
Items
1813
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions