A system that allows an alarm to be received from either side of a
single ope -
correct answer ✅Class A
primary purpose of a duct smoke -
correct answer ✅to prevent the spread of smoke within the
building
Horns, Strobes, Bells, and speakers are connected to what type of
circuit -
correct answer ✅Notification appliance circuit
that all wiring is electronically monitored for disarrangement or
break in cabling system -
correct answer ✅supervised wiring
indicate that the unit is electrically safe and meets UL product
standards -
correct answer ✅UL listing
,NICET LEVEL 1 EXAM QUESTIONS
AND ANSWERS LATEST UPDATE
provide requirements for the type of fire alarm systems in a
particular occupancy type or use group -
correct answer ✅IBC
has ability to enforce codes and standards adopted jurisdiction -
correct answer ✅fire inspector
A protected premises fire alarm system requires - hours of standby
power and an additional - minutes of alarm capacity -
correct answer ✅24-5
in building fire emergency voice/alarm communications system
hours standby and minutes of alarm -
correct answer ✅24-15
in buildings with mass notification hours standby and minutes of
alarm -
correct answer ✅24-15
Wide area building Mass Notification -
correct answer ✅7 days 60 minutes
, NICET LEVEL 1 EXAM QUESTIONS
AND ANSWERS LATEST UPDATE
garage attic and kitchen -
correct answer ✅areas where a smoke detector should not be
used
impaired suppression system is a -
correct answer ✅supervisory
a fail safe class wiring system -
correct answer ✅class d
dedicated branch circuit, Disconnecting means marked as Fire
Alarm Circuit, disconnecting means must be marked red in color -
correct answer ✅Fire Alarm Primary Power Supply
the entire lens of a visible notification appliance must be mounted
between - inches and - inches -
correct answer ✅80/96
Smoke detectors listed to UL 268 must actuate before the smoke
density in the test box reaches - percent per foot obstruction -
correct answer ✅4
AND ANSWERS LATEST UPDATE
A system that allows an alarm to be received from either side of a
single ope -
correct answer ✅Class A
primary purpose of a duct smoke -
correct answer ✅to prevent the spread of smoke within the
building
Horns, Strobes, Bells, and speakers are connected to what type of
circuit -
correct answer ✅Notification appliance circuit
that all wiring is electronically monitored for disarrangement or
break in cabling system -
correct answer ✅supervised wiring
indicate that the unit is electrically safe and meets UL product
standards -
correct answer ✅UL listing
,NICET LEVEL 1 EXAM QUESTIONS
AND ANSWERS LATEST UPDATE
provide requirements for the type of fire alarm systems in a
particular occupancy type or use group -
correct answer ✅IBC
has ability to enforce codes and standards adopted jurisdiction -
correct answer ✅fire inspector
A protected premises fire alarm system requires - hours of standby
power and an additional - minutes of alarm capacity -
correct answer ✅24-5
in building fire emergency voice/alarm communications system
hours standby and minutes of alarm -
correct answer ✅24-15
in buildings with mass notification hours standby and minutes of
alarm -
correct answer ✅24-15
Wide area building Mass Notification -
correct answer ✅7 days 60 minutes
, NICET LEVEL 1 EXAM QUESTIONS
AND ANSWERS LATEST UPDATE
garage attic and kitchen -
correct answer ✅areas where a smoke detector should not be
used
impaired suppression system is a -
correct answer ✅supervisory
a fail safe class wiring system -
correct answer ✅class d
dedicated branch circuit, Disconnecting means marked as Fire
Alarm Circuit, disconnecting means must be marked red in color -
correct answer ✅Fire Alarm Primary Power Supply
the entire lens of a visible notification appliance must be mounted
between - inches and - inches -
correct answer ✅80/96
Smoke detectors listed to UL 268 must actuate before the smoke
density in the test box reaches - percent per foot obstruction -
correct answer ✅4