WV SEPTIC INSTALLER PRACTICE –
SET #1 EXAM QUESTIONS AND
ANSWERS 2026 VERIFIED.




What is the minimum septic tank size required for a single-family dwelling with up to 4
bedrooms in WV? - ANS 1,000 gallons



For each bedroom beyond 4, how many gallons must be added to the minimum septic tank
size? - ANS 250 gallons



True or False: Metal septic tanks are approved for use in West Virginia. - ANS False



What is the required minimum clearance between a septic tank and a private water well? -
ANS 50 feet



True or False: A soil absorption system may be installed under a driveway or parking lot. -
ANS False



What is the minimum trench depth allowed for a standard soil absorption system? - ANS 18
inches




@2026/2027 ALLRIGHTS RESERVED.

, What is the maximum trench depth for a standard soil absorption system? - ANS 36 inches



How many inches of gravel must be placed beneath the distribution pipe in a trench? - ANS 6
inches



How many inches of gravel must be placed above the distribution pipe? - ANS 2 inches



True or False: The invert of the septic tank inlet must be at least 2 inches higher than the outlet
invert. - ANS True



Which type of distribution system is required on sloping ground? - ANS Serial distribution



At what slope percentage are soil absorption systems prohibited? - ANS More than 25%



True or False: Effluent from an upslope trench must flow to the downslope trench in serial
distribution. - ANS True



What is the minimum horizontal separation distance between a drain field and a stream? -
ANS 20 feet



What is the minimum horizontal separation distance between a soil absorption system and a
water well? - ANS 100 feet



True or False: Percolation rates slower than 90 minutes per inch are acceptable for standard
absorption fields. - ANS False



How many percolation test holes are required across an absorption field site? - ANS At least 4

@2026/2027 ALLRIGHTS RESERVED.

Document information

Uploaded on
April 9, 2026
Number of pages
6
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Fyndlay
3.7
(75)
Sold
421
Followers
81
Items
20098
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions