ICC BOLTING EXAM QUESTIONS AND
ANSWERS 2026 VERIFIED.
According to the IBC, the "blank" is to hire the special inspector. - ANS owner or owners
agent. 2009 IBC Section 1704.1
According to the IBC, the "blank" is the responsible for the approval of a person's qualifications
to act as a special inspector. - ANS code official. 2009 IBC, Section 1704.1
According to the IBC, discrepancy corrections are made known to the building official by: -
ANS final report. 2009 IBC, Section1704.1.2
When is the code official to be made aware of a discrepancy found during a special inspection? -
ANS If it is not corrected by the contractor. 2009 IBC, Section 1704.1.2
According to the Model Program for Special Inspection, the special inspector is to document
work that is nonconforming: - ANS In a written report - Section II B 4 - Model Programs
According to the Model Program for Special Inspection, the special inspector is to prepare
written report of inspection: - ANS After each inspection visit - Section II B 5 - Model
Programs
@2026/2027 ALLRIGHTS RESERVED.
,According to the Model Program for Special Inspection, which of the following items does not
need to be included in each inspection report? - ANS Description of discussions with the
contractor - Section B 5 - Model Programs
According to the Specification for Structural Joints using high strength bolts, the nominal
diameter of standard bolt holes shall be how much larger than the nominal bolt diameter? -
ANS 1/16 inch - Specification for Structural Joints Table 3.1
Discrepancies in the work shall be brought to the immediate attention of the "blank" for
corrective action. - ANS the contractor - 2009 IBC, Section 1704.1.2.
The special inspector shall furnish inspection reports to the "blank" and to the "blank"? -
ANS Building Official and Registered Design professional
The special inspector shall provide continuos inspection of: - ANS Single-pass fillet welds
greater than 5/16 inch in size - 2099 IBC, Table 1704.3, Item 5.3
The special inspections required by this code are not required where the work is done on the
premise of a? - ANS Approved fabricator - 2009 IBC, Section 1704.2.2
The special inspection of the steel fabrication process shall not be required where the fabricator
does not perform any? - ANS heating operations - 2009 IBC, Section 1704.3, Exceptions # 1
According to the Specifications for Structural Steel Buildings, ASTM Standard "blank" is to be
used for the material test for steel sheets. - ANS A568 - Section A31, Specifications for
Structural Steel Buildings
@2026/2027 ALLRIGHTS RESERVED.
, According to the Specifications for Structural Steel Buildings, the "blank" conducts the material
tests for identification of the structural steel. - ANS Fabricator or Testing Laboratory - Section
A31, Specifications for Structural Steel Buildings.
According to the Specifications for Structural Steel Buildings, which of the following steel
members are allowed to be unidentified steel? - ANS Unimportant members, where their
physical properties and weldability would not affect the structure strength - Section A31b,
Specifications for Structural Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel of
special material to be identified? - ANS It is marked by the supplier - Section 5.1.1, Code of
Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, how are fabricators
stock steel material identified? - ANS Certified mill test reports - Section 5.2.2 - Code of
Standard Practice for Steel Buildings and Bridges
According to the Specification for Structural Steel Buildings, what ASTM Standard would apply
to a sample for structural steel pipe? - ANS A53 - Section A31a - Specification for Structural
Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, the number of
samples required to be tested for structural steel is: - ANS The number specified by the ASTM
specification - Section 5.1.1 - Code of Standard Practice for Steel Buildings and Bridges
According to the Specification for Structural Steel Buildings, which ASTM standard would apply
to a sample for structural steel plates? - ANS A36, A283, and A242 - Section A31a -
Specification for Structural Steel Buildings
@2026/2027 ALLRIGHTS RESERVED.
ANSWERS 2026 VERIFIED.
According to the IBC, the "blank" is to hire the special inspector. - ANS owner or owners
agent. 2009 IBC Section 1704.1
According to the IBC, the "blank" is the responsible for the approval of a person's qualifications
to act as a special inspector. - ANS code official. 2009 IBC, Section 1704.1
According to the IBC, discrepancy corrections are made known to the building official by: -
ANS final report. 2009 IBC, Section1704.1.2
When is the code official to be made aware of a discrepancy found during a special inspection? -
ANS If it is not corrected by the contractor. 2009 IBC, Section 1704.1.2
According to the Model Program for Special Inspection, the special inspector is to document
work that is nonconforming: - ANS In a written report - Section II B 4 - Model Programs
According to the Model Program for Special Inspection, the special inspector is to prepare
written report of inspection: - ANS After each inspection visit - Section II B 5 - Model
Programs
@2026/2027 ALLRIGHTS RESERVED.
,According to the Model Program for Special Inspection, which of the following items does not
need to be included in each inspection report? - ANS Description of discussions with the
contractor - Section B 5 - Model Programs
According to the Specification for Structural Joints using high strength bolts, the nominal
diameter of standard bolt holes shall be how much larger than the nominal bolt diameter? -
ANS 1/16 inch - Specification for Structural Joints Table 3.1
Discrepancies in the work shall be brought to the immediate attention of the "blank" for
corrective action. - ANS the contractor - 2009 IBC, Section 1704.1.2.
The special inspector shall furnish inspection reports to the "blank" and to the "blank"? -
ANS Building Official and Registered Design professional
The special inspector shall provide continuos inspection of: - ANS Single-pass fillet welds
greater than 5/16 inch in size - 2099 IBC, Table 1704.3, Item 5.3
The special inspections required by this code are not required where the work is done on the
premise of a? - ANS Approved fabricator - 2009 IBC, Section 1704.2.2
The special inspection of the steel fabrication process shall not be required where the fabricator
does not perform any? - ANS heating operations - 2009 IBC, Section 1704.3, Exceptions # 1
According to the Specifications for Structural Steel Buildings, ASTM Standard "blank" is to be
used for the material test for steel sheets. - ANS A568 - Section A31, Specifications for
Structural Steel Buildings
@2026/2027 ALLRIGHTS RESERVED.
, According to the Specifications for Structural Steel Buildings, the "blank" conducts the material
tests for identification of the structural steel. - ANS Fabricator or Testing Laboratory - Section
A31, Specifications for Structural Steel Buildings.
According to the Specifications for Structural Steel Buildings, which of the following steel
members are allowed to be unidentified steel? - ANS Unimportant members, where their
physical properties and weldability would not affect the structure strength - Section A31b,
Specifications for Structural Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel of
special material to be identified? - ANS It is marked by the supplier - Section 5.1.1, Code of
Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, how are fabricators
stock steel material identified? - ANS Certified mill test reports - Section 5.2.2 - Code of
Standard Practice for Steel Buildings and Bridges
According to the Specification for Structural Steel Buildings, what ASTM Standard would apply
to a sample for structural steel pipe? - ANS A53 - Section A31a - Specification for Structural
Steel Buildings
According to the Code of Standard Practice for Steel Buildings and Bridges, the number of
samples required to be tested for structural steel is: - ANS The number specified by the ASTM
specification - Section 5.1.1 - Code of Standard Practice for Steel Buildings and Bridges
According to the Specification for Structural Steel Buildings, which ASTM standard would apply
to a sample for structural steel plates? - ANS A36, A283, and A242 - Section A31a -
Specification for Structural Steel Buildings
@2026/2027 ALLRIGHTS RESERVED.