Virginia Backflow Prevention Device
Worker Exam Practice Questions And
Correct Answers (Verified Answers) Plus
Rationale 2026 Q&A| Instant Download
Pdf


1. In potable water distribution systems, the primary purpose of a
backflow prevention device is to prevent which condition from
contaminating the public water supply?
A. Excessive water pressure in municipal mains
B. Reverse flow of contaminated water into the potable supply
C. Increased water velocity in branch piping
D. Sediment accumulation in storage tanks

The correct answer is B because backflow prevention devices are
specifically designed to stop reverse flow, which can occur through
backpressure or backsiphonage and allow contaminants to enter potable
water systems.

2. Which condition most commonly causes backsiphonage in a plumbing
system?
A. High pressure within the supply line
B. Negative pressure in the supply piping
C. Excessive temperature within the piping
D. Mechanical failure of water meters

,The correct answer is B because backsiphonage occurs when the pressure
in the supply line drops below atmospheric pressure, creating a vacuum
that can draw contaminated water back into the potable supply.

3. Which type of backflow condition occurs when downstream pressure
exceeds the supply pressure?
A. Backsiphonage
B. Static pressure loss
C. Backpressure
D. Cross-connection vacuum

The correct answer is C because backpressure occurs when downstream
pressure becomes greater than upstream supply pressure, forcing water to
flow backward into the potable system.

4. A cross-connection is best defined as which of the following?
A. A pipe connection between two water meters
B. A connection between hot and cold water lines
C. A link between potable water and a potential contaminant source
D. A connection between two municipal water systems

The correct answer is C because a cross-connection is any physical
connection between potable water and a non-potable source that could
allow contamination through backflow.

5. Which device protects against backsiphonage but not backpressure?
A. Reduced pressure principle assembly
B. Double check valve assembly
C. Atmospheric vacuum breaker
D. Pressure vacuum breaker

The correct answer is C because atmospheric vacuum breakers only protect
against backsiphonage and cannot be used where backpressure conditions
exist.

6. An atmospheric vacuum breaker must be installed at least how far
above the highest downstream outlet it serves?

, A. 1 inch
B. 3 inches
C. 6 inches
D. 18 inches

The correct answer is C because atmospheric vacuum breakers require
installation at least 6 inches above the highest outlet to ensure proper
operation during siphon conditions.

7. Which backflow prevention assembly is designed to protect against
both backsiphonage and backpressure hazards and includes a relief
valve?
A. Atmospheric vacuum breaker
B. Hose bib vacuum breaker
C. Double check valve assembly
D. Reduced pressure principle assembly

The correct answer is D because a reduced pressure principle assembly
contains two check valves and a pressure-monitored relief valve, providing
protection from both backpressure and backsiphonage.

8. A double check valve assembly primarily protects against which type
of hazard?
A. High health hazard contamination
B. Low to moderate hazard backflow conditions
C. Industrial chemical contamination
D. Toxic waste backflow

The correct answer is B because double check valve assemblies are
typically used where contaminants pose a non-health hazard risk to the
potable water supply.

9. What is the primary function of check valves within a double check
valve assembly?
A. To increase water pressure
B. To filter contaminants

Documentinformatie

Geüpload op
23 maart 2026
Aantal pagina's
30
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$23.99

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kan je een ander document kiezen. Je kan het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
CertCrush
3.6
(21)
Verkocht
122
Volgers
1
Items
5876
Laatst verkocht
1 dag geleden


Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen