Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Journeyman Oil Maine Fuel Board Rules Exam Questions With Complete Answers

Rating
-
Sold
-
Pages
27
Grade
A+
Uploaded on
09-03-2026
Written in
2025/2026

Journeyman Oil Maine Fuel Board Rules Exam Questions With Complete Answers .What must you do if you notice code violations in a homeowners house? - ANSWERS-Notify them and recommend ways to address them .What must be done when performing an annual tune-up on a heating system? - ANSWERS-A combustion efficiency test and a copy must be posted on site .Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must be brought into compliance with what requirements BEFORE appliance can be fired? - ANSWERS-NFPA 31 .When an emergency arises that does not allow adequate time to get a chimney lined/and or repaired before installing the new heating appliance the licensee may defer the required repairs for how long? - ANSWERS-90 days .What must be performed before a new installation? - ANSWERS-A heat loss system design and load calculation. A copy must be retained to be presented upon request of board inspector .All oil fired BOILERS must be provided with a properly installed and operating what? - ANSWERS-Low Water cut off .Where shall a low water cutoff be installed? - ANSWERS-At the level recommended by the manufacture, but in no case below the crown sheet .If the low water cut off is not installed directly in the boiler where may it be installed? - ANSWERS-Main supply line (vertical riser) as close to boiler as possible, or in a water column of continuous piping attached directly to the boiler .A listed lever or wheel thermally operated oil shut off valve must be installed where? - ANSWERS-At the burner and the oil supply tank .When outside tanks are used a thermally operated shut off valve must be installed where? - ANSWERS-The supply line enters the inside of the building and where the oil line enters the room where the appliance is located .When inside tanks are used and the oil supply tank is installed in a separate room, a thermally shutoff valve must be installed where? - ANSWERS-Where the line enters the room where the appliance is located .Whenever the oil supply is taken from the top of an oil tank a thermally operated wheel or lever type shut-off valve must be installed where? - ANSWERS-At the tank and at the burner .What may be installed in the supply line but not a return line? - ANSWERS-A check valve .All copper oil supply and return lines must be encased in a continuous piece of no metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the conduit shall not exceed how far from any connection except the connection at fuel tank? - ANSWERS-2 inches .In order to avoid undetected oil leaks under floors, the conduit must be how much bigger than the supply and return lines? - ANSWERS-One pipe size larger .An oil supply line that penetrates a foundation wall must be what? - ANSWERS-Sealed .What must coated copper tubing have installed at the tank when used underground? - ANSWERS-Oils Safety Valve or PRV .When an oil filter or other accessory equipment is connected to a copper piping smaller than 3/4 "and is not directly connected to the oil tank or burner the filter or other device must be what? - ANSWERS-Rigidly supported by wall or floor mounted brackets .What must supply and return lines be connected with? - ANSWERS-Flare fittings .What fittings shall not be used unless for introduction of lines at top of the tank with a single or double tap bushing? - ANSWERS-Compression fittings

Show more Read less
Institution
Journeyman Oil Burners Maine
Course
Journeyman oil burners maine

Content preview

Journeyman Oil Maine Fuel Board Rules Exam
Questions With Complete Answers



\.What must you do if you notice code violations in a homeowners house? -
ANSWERS✔-Notify them and recommend ways to address them


\.What must be done when performing an annual tune-up on a heating system? -
ANSWERS✔-A combustion efficiency test and a copy must be posted on site


\.Whenever a furnace, direct fired hot water heater, or boiler is installed the total
installation must be brought into compliance with what requirements BEFORE
appliance can be fired? - ANSWERS✔-NFPA 31


\.When an emergency arises that does not allow adequate time to get a chimney
lined/and or repaired before installing the new heating appliance the licensee may
defer the required repairs for how long? - ANSWERS✔-90 days



\.What must be performed before a new installation? - ANSWERS✔-A heat loss
system design and load calculation. A copy must be retained to be presented upon
request of board inspector


\.All oil fired BOILERS must be provided with a properly installed and operating
what? - ANSWERS✔-Low Water cut off

,\.Where shall a low water cutoff be installed? - ANSWERS✔-At the level
recommended by the manufacture, but in no case below the crown sheet


\.If the low water cut off is not installed directly in the boiler where may it be
installed? - ANSWERS✔-Main supply line (vertical riser) as close to boiler as
possible, or in a water column of continuous piping attached directly to the boiler


\.A listed lever or wheel thermally operated oil shut off valve must be installed
where? - ANSWERS✔-At the burner and the oil supply tank


\.When outside tanks are used a thermally operated shut off valve must be
installed where? - ANSWERS✔-The supply line enters the inside of the building
and where the oil line enters the room where the appliance is located


\.When inside tanks are used and the oil supply tank is installed in a separate
room, a thermally shutoff valve must be installed where? - ANSWERS✔-Where the
line enters the room where the appliance is located


\.Whenever the oil supply is taken from the top of an oil tank a thermally operated
wheel or lever type shut-off valve must be installed where? - ANSWERS✔-At the
tank and at the burner



\.What may be installed in the supply line but not a return line? - ANSWERS✔-A
check valve

, \.All copper oil supply and return lines must be encased in a continuous piece of
no metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of
the conduit shall not exceed how far from any connection except the connection
at fuel tank? - ANSWERS✔-2 inches


\.In order to avoid undetected oil leaks under floors, the conduit must be how
much bigger than the supply and return lines? - ANSWERS✔-One pipe size larger


\.An oil supply line that penetrates a foundation wall must be what? -
ANSWERS✔-Sealed


\.What must coated copper tubing have installed at the tank when used
underground? - ANSWERS✔-Oils Safety Valve or PRV


\.When an oil filter or other accessory equipment is connected to a copper piping
smaller than 3/4 "and is not directly connected to the oil tank or burner the filter
or other device must be what? - ANSWERS✔-Rigidly supported by wall or floor
mounted brackets



\.What must supply and return lines be connected with? - ANSWERS✔-Flare
fittings


\.What fittings shall not be used unless for introduction of lines at top of the tank
with a single or double tap bushing? - ANSWERS✔-Compression fittings

Written for

Institution
Journeyman oil burners maine
Course
Journeyman oil burners maine

Document information

Uploaded on
March 9, 2026
Number of pages
27
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
Journeyman Oil Burner Exam Bundle
-
11 2026
$ 55.53 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
IszackBd University Of Washington
View profile
Follow You need to be logged in order to follow users or courses
Sold
39
Member since
1 year
Number of followers
3
Documents
5564
Last sold
1 week ago
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don\'t find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Read more Read less
5.0

3 reviews

5
3
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions