Content preview

NYC MASTER ELECTRICIAN EXAM GUARANTEED
PASS !!


Type ____ is multiconductor cable identified for use as underground service entrance cable. - (ANSWER)Type
USE cable


Knife switch rated for more than 1200 Amps at 250Volts or less - (ANSWER)Can be used only as isolating
switch, shall not be opened under load


Track lighting with outlets in a bathroom is not allowed because ? - (ANSWER)Track lighting has receptacle


Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an
on premise fuel supply sufficient for not less than ____ hours full demand operation of the system -
(ANSWER)6 hours


Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be
permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - (ANSWER)30
Amps


Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - (ANSWER)Both ends


GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. -
(ANSWER)Locking


The maximum voltage drop from service point to the last over-current device in a dwelling unit? -
(ANSWER)4%


Which of the following statements best describe the grounding requirement for central vacuum outlet -
(ANSWER)Accessible non current carrying metal parts are required to be connected to an equipment grounding
conductor.




Page 1 of 17

,In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two
branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system
- (ANSWER)Are permitted


Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or
similar areas - (ANSWER)Do not include


The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. -
(ANSWER)Examined or treated


Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____
duplex receptacles - (ANSWER)Single or two


A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24
hour basis of ____ or more patients - (ANSWER)Four


Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways
shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic
equipment - (ANSWER)Listed fitting


Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating
not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation
temperature - (ANSWER)3 inches


Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not
exceeding ____ ft. - (ANSWER)6 ft


Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a
____ that shall be visible with the screw installed - (ANSWER)Green finish


Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or
other prominent part to distinguish them from fuses of higher ampere rating - (ANSWER)Hexagon


The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or
the nameplate rating, which ever is larger, for each dryer served ? - (ANSWER)5000 watts

Page 2 of 17

, Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____
windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. - (ANSWER)3 ft
(36 inches)


—— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing
installation is where there is no evidence of over-fusing or tampering. - (ANSWER)Class H


Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower
it 90°C 194°F - (ANSWER)3" inches


The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - (ANSWER)8


In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? -
(ANSWER)Combination range hood/microwave oven


Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the
equipment served.if ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the
service or separately derived system disconnect - (ANSWER)Included in the manufactures instructions


Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? - (ANSWER)EVJ


Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed -
(ANSWER)Type S fuse


Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a
lesser distance is permitted by and exceptions - (ANSWER)8'ft


Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings with
conductors of Class 1 or electric light or power conductors, unless ____. - (ANSWER)Separated by barrier


In the critical care areas of health care centers, each patient bed shall be provided with a minimum of ____
duplex receptacles - (ANSWER)3 duplex (6 single)


Page 3 of 17

Written for

Institution
NYC MASTER ELECTRICIAN
Course
NYC MASTER ELECTRICIAN

Document information

Uploaded on
February 19, 2026
Number of pages
17
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
mercymutinda
5.0
(1)

Get to know the seller

Seller avatar
mercymutinda Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
4
Member since
2 year
Number of followers
0
Documents
670
Last sold
1 month ago

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions