1. What is the primary purpose of a mechanical permit?
A. To increase property value
B. To ensure code compliance and safety
C. To reduce contractor liability
D. To guarantee manufacturer warranty
Answer: B. To ensure code compliance and safety
Rationale: Mechanical permits allow the authority having jurisdiction to
verify installations meet code requirements for safety and health.
2. A mechanical inspection is required before concealment of which
system?
, A. Completed thermostat wiring
B. Installed ductwork
C. Painted registers
D. Installed carbon monoxide alarms
Answer: B. Installed ductwork
Rationale: Duct systems must be inspected before concealment to verify
proper materials, support, and sealing.
3. What is the minimum required clearance to combustibles for a typical
Type B gas vent?
A. 0 inches
B. 1 inch
C. 2 inches
D. 6 inches
Answer: B. 1 inch
Rationale: Listed Type B gas vents typically require a 1-inch clearance to
combustibles unless otherwise specified by the manufacturer.
4. What is the main purpose of a sediment trap in a gas line?
A. Increase gas pressure
B. Remove moisture and debris
, C. Reduce noise
D. Improve combustion efficiency
Answer: B. Remove moisture and debris
Rationale: A sediment trap collects debris and condensate to prevent them
from entering and damaging gas appliances.
5. What must be provided for appliances installed in attics?
A. Skylight
B. Permanent ladder
C. Access opening and service platform
D. Roof hatch only
Answer: C. Access opening and service platform
Rationale: Codes require adequate access and a service platform for safe
inspection and maintenance of attic-installed appliances.
6. What is the minimum slope required for horizontal gas piping?
A. 1/8 inch per foot
B. 1/4 inch per foot
C. 1/2 inch per foot
D. No slope required
, Answer: D. No slope required
Rationale: Gas piping does not require slope; however, proper support and
sediment traps are required.
7. Dryer exhaust ducts shall terminate:
A. In the attic
B. Under the house
C. Outdoors
D. Into a chimney
Answer: C. Outdoors
Rationale: Dryer exhaust must discharge outdoors to prevent moisture and
lint accumulation inside the structure.
8. What is the maximum length of a dryer exhaust duct unless
manufacturer states otherwise?
A. 10 feet
B. 25 feet
C. 35 feet
D. 50 feet
Answer: B. 25 feet
Rationale: The standard maximum length is 25 feet, with deductions for
fittings unless otherwise specified by manufacturer.