NATE Gas Furnace Service Preparation Version 3
Newest 2026-2027 With Complete Questions And
Correct Detailed Answers| Brand New Version!



Floor diffusers should be installed in boots or register boxes using -
ANSWER-Sheet metal screws and banding


When suspended with metal strap and no saddle, flexible duct should
be supported with a minimum strap with of - ANSWER-1 ½"


Spray-type atomizing humidifiers are installed to discharge moisture
into - ANSWER-The supply duct


A technician is installing a gas furnace and the customer has decided
not to install an air conditioner. How will their decision affect the
installation of the supply ductwork - ANSWER-Adequate space should
be allowed for addition of a coil in the future


Electronic air cleaners (EAC) installed in a gas furnace system should be
wired so they only operate - ANSWER-When the EAC ON-OFF switch is
turned to ON and the supply air blower is operating



1|Page

,Why is the polarity of a 120V gas furnace equipped with electronic
flame rectification important - ANSWER-The ignition control may not
prove the flame


Before starting a gas furnace after its installation, the technician should
do a visual check of all wiring on the equipment. Which of the following
must be included with these checks - ANSWER-A check that all
connections are secure and tight


Using a voltmeter, how does a technician determine voltage drop at a
gas furnace - ANSWER-With the furnace not operating and the with the
furnace operating


How is the setting on a 4 speed PSC blower motor changed - ANSWER-
Changing the motor tap connections


An important consideration when installing a motorized economizer is
to check to be certain that - ANSWER-The vanes operate without
binding


When starting up a dual fuel system, the temperature rise method for
determining air flow cannot be used with the compressor cycle of the
heat pump because - ANSWER-The capacity of the system varies too
much with the outdoor temperature


2|Page

,What flame pattern would the technician expect to see on a properly
operating single stage furnace equipped with in-shot type burners -
ANSWER-A hard forceful flame with a light blue appearance and little or
no yellow


Which of the following is recommended for a pressurization leak test of
a fuel gas pipe - ANSWER-Compressed air


Which of the following is used to measure air pressure - ANSWER-
Diaphragm type differential pressure gauge


A technician wishes to determine the airflow of a gas furnace on startup
using temperature rise method. The gas meter has been clocked and
gas flow rate has been determined. The gas heating value is known. The
heat rise across the heat exchanger is measures. What should the
technician do next to find the CFM - ANSWER-Calculate the CFM using a
formula


A dirty or clogged filter in an operating gas furnace can cause -
ANSWER-An increase in temperature rise




3|Page

, Why are leak detecting solutions specifically formulated for use on gas
piping preferred over household soap solutions - ANSWER-Leak
detection solutions will not damage the piping


Bent vanes of a direct blower wheel in a gas furnace can cause -
ANSWER-Loss in airflow, excessive blower motor wear and increased
noise


A gas clothes dryer can interfere with the operation of a nearby natural
draft gas furnace with an atmospheric burner by - ANSWER-Stealing the
combustion air preventing complete fuel burning


During a preventative maintenance check of a gas furnace, ductwork
should always be checked for - ANSWER-Leaks and damages


Which of the following is likely a problem if a gas furnace has a
temperature differential across the heat exchanger which exceeds the
value on the manufacturer's data plate - ANSWER-Inadequate system
airflow


When performing preventing maintenance on a gas furnace, check the
wiring to be certain - ANSWER-No wire are broken or loosened




4|Page

Document information

Uploaded on
January 22, 2026
Number of pages
34
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$25.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
johnkabiru
3.7
(572)
Sold
3317
Followers
2671
Items
6737
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions