QUESTIONS WITH SOLUTIONS GRADED A+
◉ RPM = 60 ∙ ƒ ÷ P÷2 =
Step 1. 60 x Frequency (Hz.) =
Step 2. Poles ÷ 2 =
Take answer 1 and ÷ by answer 2 = Answer: Know the formula for
RPM
435 Pg. 5
◉ If you are referring to a megohm meter, it is a test of the insulation
properties of such things as electric wiring, motor windings and high
power antenna mounts.
We use a "megger" or "meg out" electrical wiring and equipment to
see if it is shorted to ground or the frame in any way.
The megger uses much higher voltages to check resistance than a
normal Volt-ohm meter.
,Minimum resistance is 1 Meg Ohm Answer: Know what a Megger is
and what it does
636 Pg. 13
◉ (1) A parallel connection. (2) A resistive element placed across the
terminals of an armature to bypass a portion of the current. (3) A
flexible electrical conductor designed to conduct current around the
mechanical joint between two conductors. (4) The resistive element
(Usually of very low resistance) used in parallel with a DC ammeter
movement to bypass a calibrated portion of the total circuit current.
Answer: Shunt Overloads
425 All Pages
◉ Bad Ground Answer: You are using a Temp Run Box and you get
shocked! Why!
520 Pg. 4
◉ The bridle hitch can consist of two,three, or four single hitches
(fig. 3-22), used together to form a bridle hitch for hoisting an object
A sling with two legs used to lift a 1,000 pound object will have 500
pounds of the load on each leg when the sling angle is 90 degrees.
The load stress on each leg increases as the angle decreases; and if
,the sling angle was 30 degrees lifting the same 1,000 pound object,
the load will be 1,000 pounds on each leg. Try to keep all sling angles
greater than 45 degrees; sling angles approaching 30 degrees are
considered extremely hazardous and must be avoided at all cost.
Answer: Bridal Hitch
128 Pg 17
◉ Scaffolding should be tied to the structure using
#9 wire or tie-in devices. The first vertical tie
should be at the maximum height of 4 times the
narrowest base dimension. Additional ties are not
to exceed 26' vertically. Maximum horizontal
distance between ties is not to exceed 30'. Answer: Scaffolding, You
have 32' of rise, you are using 3x5 scaffolding. Where will the tie off
points be ?
140 PG. 287-288
◉ Counterweights (Typically) are hung to counter balance the
weight of the car PLUS 40% of Capacity Load. Answer: How much
should Counterweight way?
240 Pg. 14
, ◉ Note: We do not use wire smaller than #20 in travelling cables
and #24 outside travelers.
Largest wires are feeders to Hoist /Pump motor
We always have 10 % spares
10% of 52 = 5.2
On a calculator Multiply the percent 10 by the number you have and
÷ by 100
10 X 52 ÷ 100 = 5.2 Answer: Pulling Spare Wires (Example) 10% of
52 Wires
515 Pg.26
◉ The correct lube must be used on chains. Answer: The freight
door motor is spinning but the door wont move, Why?
535 Pg. 9
◉ Lula: Limited use/Limited Access (Example Wheelchair Lifts)
Max Rise 25'
Max Speed 30 Ft/Min
Max Capacity 1400 Lbs.
Max Platform Area 18 Sq/Ft.