100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

NEIEP 800 Final Exam Version 2 Actual Exam Questions and Answers with Rationales 2026/2027 | Elevator Industry Exam | Pass Guarantee

Rating
-
Sold
-
Pages
28
Grade
A+
Uploaded on
31-12-2025
Written in
2025/2026

PASS THE NEIEP 800 FINAL EXAM VERSION 2 WITH ACTUAL EXAM QUESTIONS FOR 2026/2027! This essential resource delivers real questions from the elevator industry exam, complete with verified answers and detailed technical rationales. Your definitive preparation for mastering elevator mechanics, electrical systems, safety codes, and industry regulations required for NEIEP certification and union advancement. This collection features actual exam questions from the NEIEP 800 Final Exam Version 2, updated for 2026/2027 National Elevator Industry Education Program requirements. Each question includes the verified answer and a comprehensive rationale that explains elevator mechanics, electrical principles, safety protocols, code compliance, and industry best practices. This resource ensures you're prepared for both exam success and safe, compliant elevator maintenance and repair work. WHAT THESE ACTUAL NEIEP 800 V2 EXAM QUESTIONS INCLUDE: ACTUAL NEIEP 800 FINAL EXAM QUESTIONS for Version 2 (2026/2027 Update) VERIFIED ANSWERS & DETAILED TECHNICAL RATIONALES explaining elevator systems and safety protocols VERSION 2 SPECIFIC CONTENT - Targeted preparation for this exact exam variation COMPREHENSIVE ELEVATOR COVERAGE: Mechanical Systems, Electrical Controls, Hydraulics, Safety Devices, and Code Compliance INDUSTRY CODE FOCUS - ASME A17.1 Safety Code, NEC requirements, and local regulations UNION CERTIFICATION READY - Preparation for IUEC (International Union of Elevator Constructors) advancement PRACTICAL TROUBLESHOOTING - Real-world scenarios requiring diagnostic and repair decisions Don't risk your union certification or job advancement. Get the actual exam questions that give you the definitive advantage for NEIEP 800 Version 2. Purchase now and advance your elevator industry career with confidence!

Show more Read less
Institution
NEIEP 800
Course
NEIEP 800










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NEIEP 800
Course
NEIEP 800

Document information

Uploaded on
December 31, 2025
Number of pages
28
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

1




NEIEP 800 Final Exam Version
2 Actual Exam Questions and Answers
with Rationales 2026/2027 | Elevator
Industry Exam | Pass Guarantee

Q001: A traction elevator controller is experiencing intermittent fault codes related
to encoder drift during high-speed runs. The encoder is a 1024-pulse/revolution
quadrature type directly coupled to the motor shaft. Using a digital storage
oscilloscope, you measure the A and B channel signals and notice that the duty
cycle varies between 45% and 55% as motor temperature increases. Which
component is most likely causing this issue?
Options:
A. Worn encoder coupling causing mechanical slippage
B. Encoder power supply voltage dropping below 4.5 VDC under thermal load
C. Degraded encoder bearings causing wobble and inconsistent pulse generation -
CORRECT
D. Shield grounding issue introducing noise into the controller's high -speed
counter
ANSWER: C
Q002: During a five-year full load test on a geared traction elevator, you measure
the current draw on each phase of the AC motor and find: Phase A = 38A, Phase B
= 39A, Phase C = 52A. The motor nameplate indicates 40A full-load current.
According to NEC Article 620.61(A), what is the maximum allowable current
imbalance before requiring motor winding inspection or replacement?
Options:

, 2


A. 5% average deviation
B. 8% average deviation
C. 10% maximum deviation from average - CORRECT
D. 15% maximum deviation from nameplate
ANSWER: C
Q003: An emergency brake coil on a hydraulic elevator draws 2.8A at 125 VDC
during normal operation. During a monthly inspection, you measure the coil
resistance as 52Ω at ambient temperature (20°C). The coil temperature rises to
75°C during continuous operation. Using the temperature coefficient of resistance
for copper (0.00393 per °C), what is the expected hot resistance and does it fall
within acceptable limits?
Options:
A. 62Ω, within limits (±15%)
B. 65Ω, within limits (±10%)
C. 63.5Ω, outside acceptable tolerance (±5%)
D. 64.2Ω, within acceptable tolerance (±8%) - CORRECT
ANSWER: D
Q004: You are troubleshooting a regenerative AC drive (AFE - Active Front End)
that displays "DC Bus Overvoltage" fault during light load conditions. The DC bus
voltage reads 820VDC (rated 750VDC). Which parameter in the drive's braking
chopper circuit should you investigate first according to manufacturer
specifications?
Options:
A. Braking resistor cold resistance value
B. IGBT switching frequency
C. DC bus voltage detection threshold and hysteresis settings - CORRECT
D. Input line reactor impedance

, 3


ANSWER: C
Q005: A machine room less (MRL) elevator uses a permanent magnet synchronous
motor with an integrated encoder. The controller displays "Motor Pole Position
Error" on startup. According to ASME A17.1-2022, what is the required procedure
to re-establish the pole position reference?
Options:
A. Manually rotate the motor shaft 360° and recalibrate
B. Perform an auto-tuning sequence with the brake released and car at mid-travel
C. Run the motor at reduced speed (≤3% rated) for encoder alignment, then store
offset - CORRECT
D. Replace the motor and encoder assembly
ANSWER: C
Q006: During an annual inspection, you test the elevator's emergency power
system (EPSS). When transferring to generator power, the controller loses
communication with the motor drive for 2.3 seconds, causing a safety chain fault.
The EPSS transfer time is rated at 2 seconds. According to NEC Article 620.91,
what is the maximum allowable power interruption time for microprocessor-based
elevator controllers?
Options:
A. 0.5 seconds
B. 1.0 seconds
C. 1.5 seconds - CORRECT
D. 2.0 seconds
ANSWER: C
Q007: You are analyzing a variable frequency drive's (VFD) output waveform
using a differential voltage probe and notice significant common mode voltage
spikes exceeding 500V peak-to-peak. This is causing nuisance tripping of the

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVIAACTUALEXAMS University Of California - Los Angeles (UCLA)
View profile
Follow You need to be logged in order to follow users or courses
Sold
612
Member since
2 year
Number of followers
200
Documents
4286
Last sold
1 hour ago
Actual Exam

STUVIAACTUALEXAMS is a trusted exam-success delivering accurate, verified, and exam-focused study materials that include real exam-style questions, correct answers, and clear, easy-to-follow rationales, all professionally organized to save time, eliminate guesswork, reduce stress, boost confidence, and help students secure top grades and pass their exams on the first attempt with certainty and ease.

3.6

79 reviews

5
35
4
11
3
11
2
7
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions