Type of pump that discharges waste in the sump pit and transfers the waste to the house drain. (Max Fajardo) correct answer: Sewage Ejector 
 
Minimum dimension of a septic tank manhole. correct answer: 503 mm 
 
drain that discharges objectionable waste such as acids and other chemicals from industrial equipment . correct answer: Industrial drain 
 
Minimum diameter of pipe of any water closet. correct answer: 75 mm 
 
Maximum number of water closets able to discharge into a shared 75mm dia...
![Journeyman's Plumbing Exam Questions and Answers 100% Pass](/docpics/4290896/65ad4f81e7d82_4290896_121_171.jpeg)
-
Journeyman's Plumbing Exam Questions and Answers 100% Pass
- Exam (elaborations) • 41 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Journeyman's Plumbing Exam Questions and Answers 100% Pass 1/4" Threads of drainage fittings shall be tapped as to allow _____ pitch per foot 
4 lbs Lead used for safe pans shall not be less than ________ per square foot 
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV Name 3 allowable materials for the DWV system "underground" 
1-1/4" - 1 dfu's 1-1/2" - 3 dfu's 2" - 4 dfu's 3" 6 dfu's 4" - dfu's What are the fixture unit values for the following traps 
Double fixture fitting...
![Master Plumber Exam - National Plumbing Code of the Philippines Questions With Complete Solutions](/docpics/3480013/650cf5a4c30e2_3480013_121_171.jpeg)
-
Master Plumber Exam - National Plumbing Code of the Philippines Questions With Complete Solutions
- Exam (elaborations) • 6 pages • 2023
-
Available in package deal
-
- $10.49
- + learn more
Sewage Ejector correct answer: Type of pump that discharges waste in the sump pit and transfers the waste to the house drain. (Max Fajardo) 
 
503 mm correct answer: Minimum dimension of a septic tank manhole. 
 
Industrial drain correct answer: drain that discharges objectionable waste such as acids and other chemicals from industrial equipment . 
 
75 mm correct answer: Minimum diameter of pipe of any water closet. 
 
3 correct answer: Maximum number of water closets able to discharge int...
![Journeyman's Exam Questions And Answers](/docpics/4361974/65b787e7bcb6b_4361974_121_171.jpeg)
-
Journeyman's Exam Questions And Answers
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $11.99
- + learn more
Journeyman's Exam Questions And Answers 
 
 
1/4" - ANS Threads of drainage fittings shall be tapped as to allow _____ pitch per foot 
 
4 lbs - ANS Lead used for safe pans shall not be less than ________ per square foot 
 
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - ANS Name 3 allowable materials for the DWV system "underground" 
 
1-1/4" - 1 dfu's 
1-1/2" - 3 dfu's 
2" - 4 dfu's 
3" 6 dfu's 
4" - dfu's - ANS What are the fixture unit values for the follow...
![Master Plumber Exam 1 with Correct Answers](/docpics/4041125/657eb6858ab22_4041125_121_171.jpeg)
-
Master Plumber Exam 1 with Correct Answers
- Exam (elaborations) • 56 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
Master Plumber Exam 1 with Correct Answers 
Sewage Ejector - ANS ️️ Type of pump that discharges waste in the sump pit 
and transfers the waste to the house drain. (Max Fajardo) 
503 mm - ANS ️️ Minimum dimension of a septic tank manhole. 
Industrial drain - ANS ️️ drain that discharges objectionable waste such as acids 
and other chemicals from industrial equipment . 
75 mm - ANS ️️ Minimum diameter of pipe of any water closet. 
3 - ANS ️️ Maximum number of water closets abl...
![Journeyman's Exam Questions and Answers 100% Solved](/docpics/4707091/65ecbfd774c29_4707091_121_171.jpeg)
-
Journeyman's Exam Questions and Answers 100% Solved
- Exam (elaborations) • 17 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Journeyman's Exam Questions and 
Answers 100% Solved 
1/4" - answerThreads of drainage fittings shall be tapped as to allow _____ pitch per foot 
4 lbs - answerLead used for safe pans shall not be less than ________ per square foot 
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - answerName 3 allowable 
materials for the DWV system "underground" 
1-1/4" - 1 dfu's 
1-1/2" - 3 dfu's 
2" - 4 dfu's 
3" 6 dfu's 
4" - dfu's - answerWhat are the fixture unit values for the followi...
![Journeyman's Exam Questions and Answers 100% Solved](/docpics/4693198/65ea44758cd56_4693198_121_171.jpeg)
-
Journeyman's Exam Questions and Answers 100% Solved
- Exam (elaborations) • 17 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman's Exam Questions and 
Answers 100% Solved 
1/4" - answerThreads of drainage fittings shall be tapped as to allow _____ pitch per foot 
4 lbs - answerLead used for safe pans shall not be less than ________ per square foot 
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - answerName 3 allowable 
materials for the DWV system "underground" 
1-1/4" - 1 dfu's 
1-1/2" - 3 dfu's 
2" - 4 dfu's 
3" 6 dfu's 
4" - dfu's - answerWhat are the fixture unit values for the followi...
![Master Plumber Exam 1 Questions and Answers](/docpics/4707029/65ecbdb844299_4707029_121_171.jpeg)
-
Master Plumber Exam 1 Questions and Answers
- Exam (elaborations) • 37 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
Master Plumber Exam 1 Questions and 
Answers 
Sewage Ejector -answerType of pump that discharges waste in the sump pit and transfers 
the waste to the house drain. (Max Fajardo) 
503 mm -answerMinimum dimension of a septic tank manhole. 
Industrial drain -answerdrain that discharges objectionable waste such as acids and other 
chemicals from industrial equipment . 
75 mm -answerMinimum diameter of pipe of any water closet. 
3 -answerMaximum number of water closets able to discharge into a shared...
![Plumbing Exam Questions And Answers Graded A](/docpics/3484318/650dc67f49dfa_3484318_121_171.jpeg)
-
Plumbing Exam Questions And Answers Graded A
- Exam (elaborations) • 22 pages • 2023
-
Available in package deal
-
- $12.99
- + learn more
Which of the following drain pipes is typically used below grade? 
A) 
Copper 
B) 
Galvanized steel 
C) 
Cast iron 
D) 
Clay correct answer: The answer is CLAY. Clay drain pipes are typically used below grade. 
 
Common problems with sinks and basins include all of the following except 
A) 
excess pressure. 
B) 
rust. 
C) 
cross connections. 
D) 
leaks. correct answer: The answer is EXCESS PRESSURE. Excess pressure is not a common problem with sinks and basins. 
 
What is the component that in...
![Master Plumber Exam 1 Questions and Answers](/docpics/4693107/65ea42137c5e0_4693107_121_171.jpeg)
-
Master Plumber Exam 1 Questions and Answers
- Exam (elaborations) • 37 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
Master Plumber Exam 1 Questions and 
Answers 
Sewage Ejector -answerType of pump that discharges waste in the sump pit and transfers 
the waste to the house drain. (Max Fajardo) 
503 mm -answerMinimum dimension of a septic tank manhole. 
Industrial drain -answerdrain that discharges objectionable waste such as acids and other 
chemicals from industrial equipment . 
75 mm -answerMinimum diameter of pipe of any water closet. 
3 -answerMaximum number of water closets able to discharge into a shared...
![Verkoop je kennis op stuvia](https://www.stuvia.com/hosted-imgs/app/stock-fotos/banner_seller_big.jpg)
How much did you already spend on Stuvia? Imagine there are plenty more of you out there paying for study notes, but this time YOU are the seller. Ka-ching! Discover all about earning on Stuvia